Warning: Declaration of Jetpack_IXR_Client::query() should be compatible with IXR_Client::query(...$args) in /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php on line 51

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648
{"id":74848,"date":"2018-10-04T08:10:01","date_gmt":"2018-10-04T12:10:01","guid":{"rendered":"http:\/\/www.adarshinternational.com\/?post_type=product&p=74848"},"modified":"2018-10-04T08:11:55","modified_gmt":"2018-10-04T12:11:55","slug":"water-cooling-tower-apparatus","status":"publish","type":"product","link":"https:\/\/adarshinternational.com\/product\/water-cooling-tower-apparatus\/","title":{"rendered":"Water Cooling Tower Apparatus"},"content":{"rendered":"

[vc_row][vc_column][vc_column_text]Description[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"

The apparatus consists of a forced draught, counter flow type-cooling tower. A blower supplies cooling air. Air enters the tower at the bottom. Hot water is, obtained from a geyser. Hot water is sprayed over the mesh packing through the nozzles and it flows downwards. Evaporative cooling of water occurs due to the current of air and water gets cooled. This student can study the operation of cooling tower and calculate the energy balance.<\/p>\n

SPECIFICATION:<\/h3>\n

Cooling tower, fabricated of M.S. Sheets, 200 X 200 mm. cross section,
\n1.2m. height with Perspex front. Wire mesh packing is provided in the tower.
\nGeyser \u2013 3 Kw Capacity to provided hot water.
\nCentrifugal blower, 1 HP capacity to force air through the tower.
\nMultichannel Digital Temperature indicator to measure temperature at various points.
\nRotameter to measure inlet water flow.
\nMeasuring tank to measure outlet water flow.
\nCalibrated orifice and water manometer to measure airflow.
\nArrangement to measure dry and wet bulb temperatures of air at 5 intermediate stations.
\nA technical manual accompanies the unit. The unit Is provided with anticorrosion an attractive color powder coating.<\/p>\n

SERVICES REQUIRED:<\/h3>\n

440V, 32A, AC supply with neutral and earthing connection.
\nFloor space of about 2m. X 1.5m.
\nWater flow of 10 Ht.\/min. at constant head<\/p>\n","protected":false},"featured_media":74842,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[187],"product_tag":[],"_links":{"self":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product\/74848"}],"collection":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/comments?post=74848"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/media\/74842"}],"wp:attachment":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/media?parent=74848"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product_cat?post=74848"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product_tag?post=74848"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}