Warning: Declaration of Jetpack_IXR_Client::query() should be compatible with IXR_Client::query(...$args) in /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php on line 51

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648

Warning: Cannot modify header information - headers already sent by (output started at /home4/adar/public_html/wp-content/plugins/jetpack/vendor/automattic/jetpack-connection/legacy/class.jetpack-ixr-client.php:0) in /home4/adar/public_html/wp-includes/rest-api/class-wp-rest-server.php on line 1648
{"id":74929,"date":"2018-10-06T01:45:56","date_gmt":"2018-10-06T05:45:56","guid":{"rendered":"http:\/\/www.adarshinternational.com\/?post_type=product&p=74929"},"modified":"2018-10-06T01:52:43","modified_gmt":"2018-10-06T05:52:43","slug":"air-conditioning-trainer-window-type","status":"publish","type":"product","link":"https:\/\/adarshinternational.com\/product\/air-conditioning-trainer-window-type\/","title":{"rendered":"Air Conditioning Trainer Window Type"},"content":{"rendered":"

[vc_row][vc_column][vc_column_text]Description[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"

Window air conditioner is becoming now a day\u2019s necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is COP of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.<\/p>\n

SPECIFICATIONS:<\/h3>\n

1.Compressor \u2013 Hermetically sealed, Kirloskar make, having the capacity of 1\/10 ton of refrigeration using R-12 refrigerant to keep room temperature between 20 to 30 c.
\n2.Condenser \u2013 Finned tube type, with forced air flow over the tubes,
\n3.Capillary tube of matched length as expansion device.
\n4.Evaporator \u2013 Finned tube type with forced air flow,
\n5.Room \u2013 0.6 X 0.7 X 0.7 m. height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions.
\n6.Measurements and Controls
\n a) H.P. \/ L.P. Pressure gauges
\n b) Digital temperature indicator to measure the temperatures at various points.
\n c) Energy meters to measure input to compressor & heater.
\n d) High and low pressure cutout.
\n e) Thermostat to put off the compressor at set room temperature.
\n f) Necessary switch for electrical components.<\/p>\n

SERVICES REQUIRED:<\/h3>\n

1.Floor area of 2m X 1 m.
\n2.230V, 15AC stabilized supply with earthing connection<\/p>\n","protected":false},"featured_media":74920,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_cat":[191],"product_tag":[],"_links":{"self":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product\/74929"}],"collection":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/comments?post=74929"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/media\/74920"}],"wp:attachment":[{"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/media?parent=74929"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product_cat?post=74929"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/adarshinternational.com\/wp-json\/wp\/v2\/product_tag?post=74929"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}