Description
Metacentric Height Apparatus
DESCRIPTION:-
A pontoon is allowed to float in a small tank having a transparent side. Removable steel strips placed in the model for the purpose of changing the weight of the model. Displacement of weight is measured with the help of a scale. By means of a pendulum (consisting of a weight suspended to a long pointer) the angle of tilt can be measured on a graduated arc.
For tilting the ship model, a cross bar with two movable hangers is fixed on the model. Pendulum and graduated arc are suitably fixed at the center of the cross bar. A set of weights is supplied with the apparatus.
EXPERIMENTS:-
Ø Determination of the Metacentric height and position of the Metacentric height with angle of heel of ship model.
TECHNICAL SPECIFICATION: –
Ø Pontoon : Size 300 x 150 mm (Approx.) with a Horizontal Guide Bar for aliding weight.
Ø Material : Stainless Steel Pontoon
Ø Water Tank : Size 600 x 400 x 400 mm (Approx.)
Ø Front Window of Tank : made of Glass/Perspex
Ø A set of weights is supplied with the apparatus.
Ø The whole Set-up is well designed and arranged in a good quality painted Structure
Related products
Flow Over Weir Or Open Channel Apparatus
SPECIFICATIONS:
[1] The unit is provided with following weirs: (a) Sharp-crested weir. (b) Broad-crested weir. (c) Ogee shaped weir. [2] Pump 1/2 H.P. monoblock. [3] Flow measurement – Measuring tank calibrated water flow meter is used. A technical manual accompanies the unit.SERVICES REQUIRED:
[1] Floor surface – 2.5 m x 1.5 m. [2] 230 v, 5 amp supply with earthing connectionPilot Static Tube Set Up
DESCRIPTION:-
A Pitot tube is used to measure the local velocity at a given point in the flow stress. A Pitot tube of standard design made of copper / SS is supplied and is fixed below Vernier scale. The Vernier scale is capable to measure the position of Pitot tube in transparent pipe section. The pipe has a flow control valve to regulate the flow. A U-tube manometer is provided to determine the velocity head. Present Set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To find the point velocity at the center of a tube for different flow rates of water and calibrate the Pitot tube Ø To plot velocity profile across the cross section of pipeUTILITIES: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Pitot Tube : Material Copper/SS of compatible size fitted with Vernier Scale Ø Test Section : Material Clear Acrylic, Compatible to 1” Dia. Pipe Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank, Capacity 40 Ltrs. Ø Sump Tank : Capacity 70 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted StructureDischarge Over Notches Apparatus
DESCRIPTION:-
The Lab setup consists of a channel having sufficient length and width in which water is supplied from the bottom. Required Notch is fitted at one end of this channel .A hook gauge with Vernier scale is fitted to measure the height of fluid in flow channel. Arrangement for fixing interchangeable notches is made. Set of three brass notches, i.e. rectangular notch. 60 V notch & 45 V notch provided along with the set up. Present set – up is self –contained water re- circulating unit .provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass value are fitted in water line to conduct the experiment on different flow rate .Flow rate of water is measured with the help of measuring tank and stopwatch.EXPERIMENTS:-
Ø To Determination Co-efficient of discharge (Cd) through Ø V notch (45 deg. and 60 deg.) Ø Rectangular Notch. Ø Trapezoidal NotchUTILITIES REQUIRED: –
Ø Water Supply & Drain Ø Electricity 0.5kw,220V AC, Single PhaseTECHNICAL SPECIFICATION: –
Ø Channel Test Section : Size 600x250x180 mm Ø Notches : Material Brass(3 Nos) 1. Rectangular Notch 2. 45 deg. V Notch 3. 60 deg. V Notch 4. Trapezoidal Notch Ø Hook / Pointer : With Vernier Scale Ø Water Circulation : FHP Pump, Crompton/Sharp make. Ø Flow Measurement : Using Measuring Tank with Piezometer, Cap.25 Ltrs. Ø Sump Tank : Capacity 70 Liters. Ø Stop Watch : Electronic Ø Control Panel : On/Off Switches, Main Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted Structure.Reynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |