Showing 1–12 of 22 results

Air Conditioning Trainer General Cycle Type

The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. cooling coil). Measurements of various parameters Torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning.

SPECIFICATIONS:

1.Cooling circuits – It consists of: a) Hermetic compressor, having the capacity of 2/3 ton of refrigeration (approx.) using R-22 refrigerant. b) Rotameter for liquid refrigerant flow measurement. c) Pressure gauges for high and low pressure. d) Prescott (i.e. high and low pressure cut-out). e) Thermometers for temperature measurement at various points In the cycle. f) Energymeter for compressor input measurement. g) Condensate measuring arrangement. 2.Heating Circuit – Air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 Kw. 3.Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. in which airflow is generated by axial flow fan. 4.Anemometer for measurement of air velocity, (range 0-15 m/sec. Following experiments can be conducted on the unit a) Cooling of atmospheric air. b) Heating of atmospheric air. c) Humidification of atmospheric air. d) Dehumidification and heating of atmospheric air. (Cooling coil acts as dehumidifier at reduced airflow.)

SERVICES REQUIRED:

1.440 V, 15 A, 3 Phase supply with earthing connection. 2.Floor space area about 3 m. X 2 m.

Air Conditioning Trainer Window Type

Window air conditioner is becoming now a day’s necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is COP of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.

SPECIFICATIONS:

1.Compressor – Hermetically sealed, Kirloskar make, having the capacity of 1/10 ton of refrigeration using R-12 refrigerant to keep room temperature between 20 to 30 c. 2.Condenser – Finned tube type, with forced air flow over the tubes, 3.Capillary tube of matched length as expansion device. 4.Evaporator – Finned tube type with forced air flow, 5.Room – 0.6 X 0.7 X 0.7 m. height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions. 6.Measurements and Controls a) H.P. / L.P. Pressure gauges b) Digital temperature indicator to measure the temperatures at various points. c) Energy meters to measure input to compressor & heater. d) High and low pressure cutout. e) Thermostat to put off the compressor at set room temperature. f) Necessary switch for electrical components.

SERVICES REQUIRED:

1.Floor area of 2m X 1 m. 2.230V, 15AC stabilized supply with earthing connection

Car Air Conditioning Actual Cut Section

This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.

Desert Cooler Trainer

Desert Cooler Trainer works on the principle of evaporative cooling. It is used mostly in the dry hot regions; it consists of a fan which sucks the air from atmosphere through the pads which are used in desert coolers very frequently. The difference in DBT & WBT at inlet and outlet can be measured hence the RH from the charts. Also the amount of water evaporated can be calculated by knowing the water level difference in the reservoir.

SPECIFICATIONS:

1.Fan connected to 1/2 HP motor. 2.Air Cooler Pump to circulate water. 3.DBT & WBT Measuring Thermometer at inlet and outlet. 4.Orifice meter with manometer to measure the air flow. A technical manual accompanies the unit.

SERVICES REQUIRED:

1.Floor Area – 1, X 1 m. X 1 -5m. Height. 2.220 V., 15 Amp. , Single Phase Stabilized power supply

Domestic Refrigerator Actual Cut Section

This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.

Handheld Anemometer Digital

This apparatus is used to calculate the wind or air velocity. We can place the anemometer in front of air vent of a window air conditioner and record the air velocity.

Ice Plant Trainer

The Plant uses ice can system. The cans filled with fresh wafer are kept in a tank in which brine is circulated. The brine is cooled by the refrigerant, which in turn cools the water in can and ice formation takes place.

SPECIFICATIONS:

1.Compressor : Kirioskar make hermetically sealed compressor using R 12 Refrigerant. 2.Condenser : 4 row type air cooled. 3.Expansion Valve : 0.5 TR capacity. 4.Evaporator : 1/2″ O.D. copper tube – 75 feet long. 5.Filter – Drier : Silica gel filled – 3/8″ flare connections. 6.Main Tank : 600 mm X 375 mm 7.Total Ice Cane Capacity : 7 Kg 8.Ice Making Capacity : 7 Kg / 4 Hours. 9.Thermocol insulation : 6.5″ 10.Brine Stirrer : Motor driven fan, 1 phase, 1/10 HP, 1440.

INSTRUMENTATION:

1.Temperature Indicator : Digital Type O300°c, with 1 °c least count, using Cr/Al thermocouples. Accuracy 1 % of full reading. 2.Compressor Energy Meter : Single Phase, 10 – 20 Amp. Capacity. 3.Pressure Gauge: a)0-21 Kg/cm2 b) -1 to 10.6 Kg/cm2 c) Both of 65 mm dial. 4.Digital Thermometer CONTROLS : 1.HP/LP Cutout : Auto reset type. 2.Thermostat : Auto reset type. A technical manual accompanies the unit.

SERVICES REQUIRED:

1.Floor Area – 2m. X 1.5m. X 1.5m. Height. 2.220 V., 15 Amp.Single Phase Stabilized power supply

Mechanical Heat Pump Trainer

Heat Pump is a device to pump heat from one source to another. The heat obtained by heat pump is more than that could be obtained by direct electrical heating. The apparatus consists of refrigeration system with water cooled shell and coil type evaporator and condenser.

SPECIFICATIONS:

1.Compressor – Hermetically sealed compressor using R-12 refrigerant, having capacity 0.3 tons of refrigeration. Condensing pressure – max. 15 Kg/cm2 (Actual pressures will depend upon working conditions). 2.Condenser – Shell and coil type with continuous water flow arrangement. 3.Evaporator – Shell and coil type with continuous water flow arrangement. 4.Expansion Valve – Internally equalized thermostatic expansion valve. 5.Measurements – a) Rotameter for condenser & evaporator water flow rate measurement. b) Rotameter for liquid refrigerant flow measurement. c) Pressure gauges for condensing and evaporating pressure – 2 Nos. d) Thermometer for refrigeration cycle & water temp, measurement – 7 e) Wattmeter for compressor input measurement. f) Ammeter for compressor current measurement. 6.Controls – a) HP/LP cutout for compressor. b) Overload protector for compressor. c) Gate valve to control water flow rates. d) Necessary switches and fuse. A technical manual is accompanies the unit.

SERVICES REQUIRED:

1.Floor surface area – 2m, X 2m. X 1.5m. height. 2.220V. 15Amp. Single Phase Stabilized power supply.

Probe Type Anemometer Digital

This apparatus is used to calculate the wind or air velocity it has a special probe that can easily enter into air ducts. We can place the anemometer inside the air ducts of air conditioner and record the air velocity.

Reciprocating Compressor Actual Cut Section

This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.

Refrigerant Charging Unit

This charging unit is fitted with motorised vacuum pump and other safety devices like pressure gauge. With the help of this charging unit students can charge the refrigerant gases into compressor or store the gas of a refrigerator or air conditioner inside the cylinder fitted inside the charging unit that can be used later.