Description
Bernoulli S Theorem Apparatus
DESCRIPTION:-
The Set-up is designed to verify Bernoulli’s Theorem experimentally. Set up consists of a one piece clear acrylic test section with convergent and divergent part section, supply tank, measuring tank, inlet water tank and pump for closed loop water circulation. The test section is connected to Piezometer tubes through pressure tapping at different locations on the section to demonstrate the Bernoulli’s Theorem. The flow rate of water is measured using measuring tank and stop watch provided.
EXPERIMENTS:-
Ø To verify Bernoulli’s Theorem experimentally.
FEATURES:-
Ø Clear test section
Ø Closed loop water circulation
Ø Compact & stand alone setup
Ø Stainless Steel tanks and wetted parts
Ø Superb Painted structure
Ø Simple to operate & maintain
UTILITIES REQUIRED: –
Ø Electricity Supply: Provide 230 +/- 10 VAC, 50 Hz, Single Phase electric supply with proper earthing (Neutral – Earth voltage less than 5 VAC) 5 A, three pin socket with switch for pump
Ø Water Supply : Tap water connection ½ “ BSP, Distilled water @ 60 Ltrs. (Optional)
TECHNICAL SPECIFICATION: –
Ø Test Section : Material Acrylic, Size
Ø Inlet Tank : Capacity 20 Liters., Stainless Steel
Ø Supply Tank : Capacity 70 Liters., Stainless Steel
Ø Measuring Tank : Capacity 20 Ltrs. Fitted with Piezometer Tube & Scale
Ø Piezometer Tubes : Material P.U. Tubes (9 Nos.)
Ø Pump : FHP Capacity make Tullu/Crompton Graves
Ø Piping : GI / PVC Size BSP
Ø Stop Watch : Electronic
Ø The whole Set-up is well designed and arranged in a good quality painted Structure.
Related products
Study Of Pipe Fitting
DESCRIPTION:-
The Set-up consists of a ½ bend and elbow, a sudden expansion & sudden contraction fitting from 15 mm to 25 mm, ball valve and gate valve. Pressure tapings are provided at inlet and outlet of these fittings under test. A differential manometer fitted in the line gives pressure loss of individual fitting. Present Set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To determine loss of head in the fitting at various water flow rates. Ø To measure the loss co-efficient for the pipe fittings.UTILITIES REQUIRED: –
Ø Water Supply and Drain Ø Electricity Supply: Single Phase, 220 V AC, 0.5 kW.TECHNICAL SPECIFICATION: –
Ø Sudden Enlargement : From 15 mm to 25 mm Ø Sudden Contraction : From 25 mm to 15 mm Ø Bend : ½ Ø Elbow : ½ Ø Ball Valve : ½ Ø Gate Valve : ½ Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank with Piezometer, Capacity 25 Ltrs. Ø Sump Tank : Capacity 50 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. The whole Set-up is well designed and arranged in a good quality painted StructureStudy Of Flow Measurement Devices
SPECIFICATIONS:
[1] Intergratiry Type Turbine flow meter. [2] Glass Tube Rotameter. [3] Orificemeter differential manometer. [4] Venturimeter [5] Measuring Tank [6] Stop Watch (Digital) [7] 112 HP Monoblock Pump. [8] A differential manometer. [9] Sump tank of suitable capacity. A technical manual accompanies the unit.SERVICES REQUIRED:
[1] Flow surface 2 mtrs. X 1 mtr. X 1.5 mtrs. height. [2] 230 Volts, 5 Amp. Stabilized AC.Power SupplyReynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |
Reviews