CALL US : +91 9996340500
  • CONTACT US
Adarsh International Adarsh International
Login / Register
0 Wishlist
3 items / ₹0.00
Menu
Adarsh International
3 items / ₹0.00
Browse Categories
  • Physics & Electronic InstrumentsPhysics & Electronic Instruments

    • Physics Lab Instruments
      • Heat and thermodynamics
      • Magnetism
      • Electricity
      • Models
      • Optics
      • Wave And Sound
      • Measurement
      • Meters
    • Electronic Lab Trainers
      • Advanced Digital Drives Lab
      • Communication Lab
      • Control System Lab
      • Digital Signal Processing Lab
      • Instrumentation Lab
      • Wireless Sensor Network Lab
      • Internet of Things
      • Mechanical Lab
      • Microprocessor & Controller Lab
      • Plc Application Module lab
      • Power Electronic Lab
      • Special Products
      • Power System Lab
      • Process Control Lab
      • RF Microwave Lab
      • Robotics Lab
      • Smart Grid Lab
      • Vlsi Technology Lab

  • Chemistry Lab EquipmentsChemistry Lab Equipments
    • Chemistry Lab Equipments
      • Porcelain Ware
      • Silica Ware
      • Wooden Racks And Stands
      • Types Of Burner
      • Lab Rubber Tubing
      • Gas Tab And Fitting
      • Lab Brushes
    Control-Tap
    Burner-Bunsen-LPG-
    Gas-Tap-Economy
  • Biology Lab InstrumentsBiology Lab Instruments

    Aids-Virus
    cpr-trainer-manikin-torso
    Rotary-Microtome
      • Human Anatomy Models
      • Manikins Models
      • Human Heart And Artery Models
      • Prepared Slides
      • Botanical Models
      • Biology Charts
      • Biology Specimen
      • Microtomes
      • Zoology Models
      • Dental(Stomatology) Training Models
      • Dissecting Lab Tools
      • Nursing Medical
    Dental-Care-Model-28-Teeth-PVC
    Dissecting-Scissors-Blunt-Ends
    Airway-Intubation-Model

  • Mathematics LabMathematics Lab
  • Laboratory PlasticwareLaboratory Plasticware

    • Lab Plasticwares
      • Laboratory Baskets
      • Laboratory Beakers
      • Laboratory Boxes
      • Laboratory Containers
      • Laboratory Flasks
      • Laboratory Vials
      • Measuring Cylinders
      • Lab Tubing Connectors
      • Laboratory Burette
      • Laboratory Desiccators
      • Stop Cocks
      • Reagent Reservoirs
      • Petri Dish
      • Animal Cages
      • Conical Measures
      • Slide Mailer
      • Pipette Pump
      • Laboratory Tubes
      • Laboratory Stands
      • Aspirators Bottles
      • Laboratory Funnels
      • Laboratory Funnels
      • Pneumatic Trough
      • Policemen Stirring Rods
      • Test Tube Caps
      • Laboratory Ice Bucket
      • Laboratory Spatula
      • Laboratory Stirrers
      • Carboys
      • Plantation Pots
      • Laboratory Jars
      • Cryo Coders
      • Fisher Clamp
      • Funnel Holder
      • Kipps Apparatus
      • L Shaped Spreader
      • Measuring Jugs
      • Laboratory Bottles
      • Laboratory Trays
      • Crystal Model Set
      • Atomic Model Set
      • Laboratory Racks
      • Soft Loop Sterile

  • Laboratory GlasswareLaboratory Glassware

    • Lab Glasswares
      • Beakers
      • Bottles
      • Burette
      • Columns
      • Condenser
      • Funnels
      • Pipettes
      • Tubes
      • Evaporating Dish
      • Iodine Flask
      • Desicator
      • Kjeldahl Flask
      • Volumetric
      • Specific Gravity Bottles
      • Distillation
      • Crucibles
      • Cylinders
      • Flasks
      • Filtration Assembly
      • Stopcocks
      • Filter Flask
      • Reagent Bottles
      • Weighing Bottles
      • Dish
      • Flasks Volumetric
      • Stoppers
      • Bod Bottles
      • Distillation Flask
      • Aspirators Bottles
      • Measuring Cylinders
      • Joints
      • Utility Sets

  • Pharmacy InstrumentsPharmacy Instruments
  • Engineering  & Electronic Lab EquipmentsEngineering & Electronic Lab Equipments

    • Engineering Lab Equipments
      • Refrigeration & Air Conditioning Lab
      • Theory of Machine Lab
      • Fluid Mechanics Lab
      • Heat Transfer Lab
      • Thermodynamics Lab
      • Structural Mechanics Lab
      • Engineering Apparatus, Models & Charts
      • Automobile Engineering & I.C. Engine Lab
      • Electronic Lab Trainers
      • Cnc Trainers
    • Electronic Lab Trainer
      • Advanced Digital Drives Lab
      • Communication Lab
      • Control System Lab
      • Digital Signal Processing Lab
      • Instrumentation Lab
      • Wireless Sensor Network Lab
      • Mechanical Lab
      • Microprocessor & Controller Lab
      • Plc Application Module lab
      • Power Electronic Lab
      • Special Products
      • Power System Lab
      • Process Control Lab
      • RF Microwave Lab
      • Robotics Lab
      • Smart Grid Lab
      • Vlsi Technology Lab
    level-process-controller
    Cyclone-IV-FPGA-Controller
    8085-microprocessor-lc-lcd-trainer

  • Survey InstrumentsSurvey Instruments
  • Entomology EquipmentsEntomology Equipments
  • GeographyGeography

    • Geography
      • Models
      • Rocks & Minerals
      • Tools
    Globe-illuminated-dual-purpose
    minerals-collection
    soil-auger-cadimum-plated

  • Bio TechnologyBio Technology
  • MicroscopesMicroscopes
  • chartscharts
  • Home
  • Company Profile
  • Products
  • Exhibitions
  • Contact Us
  • Certificate
  • Register
  • SPECIAL OFFER
  • PURCHASE THEME
“Heat Transfer In Aagitated Vessel” has been added to your cart. View cart
Click to enlarge
HomeEngineering & Electronic Lab EquipmentsHeat Transfer Lab Citical Radius Of Insulating Material
Previous product
Heat Pipe Apparatus
Heat Pipe Apparatus
Back to products
Next product
Pin Fin Appatatus
Pin Fin Appatatus

Citical Radius Of Insulating Material

Citical Radius of Insulating Material:
At particular radius of insulation over a cylinder, loss of heat is maximum. The unit consists of a G.I. pipe provided with plaster of Paris insulation on out side surface. Four pipes are provided with heater inside having input control. Input to heaters is measured by common voltmeter and ammeter, by controlling input to heaters, it is shown that critical radius of insulation is ratio of thermal conductivity and outside heat transfer co-efficient.

SPECIFICATIONS:

1.G. I. Pipes with electrical heater inside – 4 Nos.
2.Insulation over the pipes of different thickness.
3.Controls and Measurements –
a) Dimmerstat to control heater input – 4 Nos.
b) A voltmeter and ammeter to measure inputs to heater.
c) Digital temperature indicator to measure temperatures across insulation.
d) Necessary switches and controls.

A technical manual accompanies the unit.

SERVICES REQUIRED:

230 V, 5 Amp., A.C., Supply with earthing connection.
Floor Area of 1 m. X 1 m X 1.5m. height.

Add to Wishlist
Compare
Compare
Add to wishlist
Compare
Category: Heat Transfer Lab
Share
  • Description
  • Reviews (0)
  • Shipping & Delivery
Description

Description

Reviews (0)

Reviews

There are no reviews yet.

Be the first to review “Citical Radius Of Insulating Material” Cancel reply

Your email address will not be published. Required fields are marked *

Shipping & Delivery

Related products

Compare
Close

Natural Convection Apparatus

The unit consists of a vertical brass pipe heated by a cartridge heater inside it. The pipe looses heat to atmosphere by natural convection. It is fitted in an enclosure to provide undisturbed natural convection currents. Thermocouples are attached on the pipe to measure local temperatures. Heater input is measured on voltmeter and ammeter. Thus students can determine overall heat transfer coefficient and local transfer coefficients in natural convection at various heat transfer rates.

SPECIFICATIONS:

1.Pipe – Brass pipe, 38mm. dia. (OD) 500mm. long, fitted with cartridge heater inside. 2.Thermocouples are fitted along with the length of pipe for Temperature measurement – 7 nos. 3.Enclosure 200mm. x 200mm. x 800mm. size, with one side of Perspex sheet. 4.Measurements & Controls a) A Dimmerstat for heater input control. b) Voltmeter and Ammeter for heater input measurement. c) Multichannel digital temperature indicator. A technical manual accompanies the unit.

SERVICES REQUIRED:

1.Bench area of 1.5m x 0,75m. at working height. 2.230v, 5A, AC, electric supply with earthing connection.
Add to wishlist
Add to cart
Quick view
Compare
Close

Theramal Conductivity Of Insulating Slabs

The apparatus consists of a slab assembly. The main Heater and a radial guard heater are sandwiched between copper plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other Sides of the specimen. The radial guard heater ensures all heat of the main heater to pass axially through the specimens which is collected by cooling plates. By knowing the temperatures and Heat input, thermal conductivity of specimen can be calculated. The test set up is enclosed in an enclosure with insulation inside to provide undisturbed Surroundings. The design style of the apparatus is similar to as recommended in INDIAN standard. The difference is in sizes.

SPECIFICATIONS:

1.Heaters: a)Main heater plate 110 mm dia. with mica heater Sandwiched between copper plates. b)Radial guard heater plate I.D. 120mm and OD 200 mm mica heater sandwiched between copper plates. 2.Water circulated cooling plates -2 nos. 3.Dimmerstat-2 A capacity – 2 nos. to independently control Inputs to the heaters. 4.Measurements – A voltmeter and an Ammeter with selector switches to measure inputs,Multichannel digital temperature indicator to measure Temperatures at various points, having 0.1 °c least count. A technical manual accompanies the unit.

SERVICES REQUIRED:

1.230 V, A.C. stabilized supply along with earthing connection. 2.Water supply of about 4-5 lit/min. 3.Bench area 1m x lm x O.5m height.
Add to wishlist
Add to cart
Quick view
Compare
Close

Lagged Pipe Apparatus

Lagged Pipe Apparatus: The apparatus consists of three concentric pipes mounted on suitable stand. The space between innermost and the middle pipe is fifed with a lagging material and the space between the middle and the outer most is filled with and other lagging material. The lagged pipe is heated with a cartridge heater inserted at the axle length of the pipe. Voltmeter and ammeter on the panel can measure the input to the heater. The intermediate temperatures can be measured by the thermocouples attached at the surfaces of the pipe. Thus the resultant conductivity of the materials can be found out.

SPECIFICATIONS:

1.Pipes : a)Gl pipe (innermost) – 6 cm. (Outer Diameter). b) Gl Pipe (Middle) – 8.5 cm. (Mean Diameter) c)G! Pipe (Outermost) – 10.7 cm. (inner Diameter) d)Length of pipes 1 Meter. 2.Heater : Nichrome wire cartridge heater placed centrally, of suitable capacity. 3.Control Panel : a)Single Phase Dimmerstat – 1 No. b)Voltmeter (0 – 250V) – 1 No. c)Ammeter (0- 2A) – 1 No. 4.Temperature Indicator : Multichannel Digital Temperature Indicator ranging (0 – 300 C) using Cr/AI Thermocouples

Services Required:

1. A.C. Single Phase 230 V electric supply 2. Floor Area-1.5 Meter X 1 Meter X 0.5 Meter High
Add to wishlist
Add to cart
Quick view
Compare
Close

Thermocouple Calibration Test Rig

The Unit helps in calibrating given thermocouple for the range 0°C to 100°C. While calibrating, thermocouple is once dipped in ice for 0Q C and then in boiling water for 100°C. This is done till the thermocouple shows the actual temperature of ice (0° C) and boiling wafer (100°C) and a linear calibration is set. A mV meter is provided to know the corresponding voltage.

SPECIFICATIONS:

1.A digital mV Meter and a digital temperature indicator with 2 different type of thermocouples. 2.A water container with heater of 1 KW. 3.A technical manual accompanies the unit.

SERVICES REQUIRED:

1.Table surface area – 2 m X 1 m X 0.5 m height. 2.220V, 50hz. Stabilize Electric Power Supply. 3.Ice cubes – 0.5Kg. Approx.
Add to wishlist
Add to cart
Quick view
Compare
Close

Specific Heat Of Air Apparatus

The apparatus consists of heating element on which the air is blown. The difference in temperature of air is shown by the temperature indicator. The flow of air is measured by the orifice meter. The input to the heater is measured by voltmeter and ammeter. Thus the specific heat of air can be found out.

SPECIFICATIONS:

1.Air blower connected to FHP motor. 2.Orifice meter to measure the air flow, Heater – 1 KW heating coil placed centrally in the test section. 3.Multi channel digital temperature indicator – range 0 to 300 c. 4.Voltmeter and ammeter to measure the heat Input.

SERVICES REQUIRED:

1.220 volts single phase stabilized AC Electric supply. 2.Floor space – 2 m. X 1 m. X 2 m. Height.
Add to wishlist
Add to cart
Quick view
Compare
Close

Composite Walls Apparatus

Composite Walls Apparatus: The apparatus consists of a pair of M.S. plates, Bakelite, brass/aluminum. These plates in series on either side of the heater form a composite wall. The whole unit is clamped in a frame, which can be viewed through the Perspex sheet. The thermocouple tapings enables us to find out the conductivity and resistance of the composite walls.

SPECIFICATIONS:

1.Heater- Mica healer of dia. 250 mm. 2.Plates- a) M.S. plates of thickness 25mm & dia. 250mm.-2 nos. b) Bakelite plates of thickness 10mm & dia. 250mm.-2 nos. c)Brass/Aluminum plates of thickness 15mm & dia. 250mm.-2nos 3.Dimmerstat – 2 A capacity. 4.Measurements — a) voltmeter and an Ammeter to measure input power. b) Multichannel digital temperature indicator to measure temperatures at- various points. A technical manual accompanies the unit.

SERVICES REQUIRED:

230 V, A.C. stabilized supply along with earthing connection. Bench area Im x lm x 0.5m height
Add to wishlist
Add to cart
Quick view
Compare
Close

Concentric Tube Heat Exchanger

(A)Plain Tube ( Water To Water ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. While the outer tube consists of GI pipe through which cold water flows. The arrangement enables the parallel and counter flow of the cold water. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D, 12.7mm. and outer G. I. Pipe I. D. 15mm. approx. and 1.5m. length. 2.Thermometers – 4 nos. 3.Measuring flask – 1 Lit. capacity. 4.Geyser-3 kW. Single phase.

Services required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x I m x 1 m height. (B) Finned Tube ( Water To Air ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. It is finned at its outer diameter to increase the heat transfer surface. While the outer tube consists of GI pipe through which cold air flows. The arrangement enables the parallel and counter flow of the air. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D. 12.7mm. and outer G. I. Pipe I. D. 25mm. approx. and 1m. length. 2.Thermometers – 4 nos. 3.Orifice meter along with manometer. 4.Measuring flask – 1 Lit. Capacity. 5.Geyser-3 kW. Single phase.

Services Required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x 1m x 1m height.
Add to wishlist
Add to cart
Quick view
Compare
Close

Heat Pipe Apparatus

Heat Pipe Apparatus: Heat pipe is an interesting device, which is used to transfer heat from one location to another. The apparatus consists of three pipes, viz. A heat pipe, copper pipe and stainless steel pipe. Ail the pipes have same physical dimensions. Copper and stainless steel pipes serve the purpose of comparison of heat pipe performance. All pipes are mounted vertically with a band heater at lower end and water filled heat sink at upper end. Nearly isothermal operation of heat pipe is clearly visualized from longitudinal temperature distribution of the pipe.

SPECIFICATIONS:

1.Heat pipe – Stainless Steel pipe, 25 mm O.D., 450 mm. Long. Sealed at both ends, evacuated and filled partially with distilled water – one No. 2.Copper and stainless steel pipe of same size as that of heat pipe – one each. 3.Equal capacity heater at bottom end of each pipe. 4.Water filled heat sinks at upper end of each pipe.

Measurements and controls

a) Dimmerstat to control heat input to all the heaters – 4 amp. Capacity One No. b) A voltmeter and an ammeter to measure input to heaters One each. c) Multichannel digital temperature indictor to measure temperatures along the length of pipes.Four thermocouples are provided on each pipe. v Thermometers to note down water temperatures in heat sinks – 3 Nos.

Services Required:

230 VA.C. Single Phase supply. Floor Area = 1 m X 0.5m X 0.5 m height.
Add to wishlist
Add to cart
Quick view
5368, Cross Road No.2, Nicholson Road
Near Congress Bhawan,
Ambala Cantt. - 133001
+91 9996340500
adarshinternational@gmail.com
WhatsApp +91 98963 24793
Categories
  • Physics Lab Instruments
  • Chemistry Lab Equipments
  • Biology Lab Instruments
  • Laboratory Glassware & Plasticware
  • Engineering Lab Equipments
  • Bio Technology
Social Media

ADARSH INTERNATIONAL 2018 CREATED BY EKARIGAR
payments
  • Home
  • Company Profile
  • Products
  • Exhibitions
  • Contact Us
  • Certificate
  • Register
  • Wishlist
  • Login / Register
Shopping cart
close
Enquiry Form
close slider

Error: Contact form not found.

WhatsApp us

Sign in

close

Lost your password?

No account yet?

Create an Account