Cryo Bath are one of the very important equipments which are used in several laboratory utilities.
These cryo baths are generally used for the purpose of freezing down the tissue samples at drastically low temperatures in very quick span of time while keeping the samples intact, distortion free and free from microscopic ice crystals.
Micro-controller based temperature controller for temperature control.
The unit is mounted on castor wheels for ease of mobility.
Circulating pump for uniform temperature.
Cabinet construction with stainless steel interior tanks to withstand critical applications.
Audio visual alarm for controlling temperature deviation from preset temperature.
Display of set value & process value.
Integrated industrial strength pump for internal circulation.
Temperature uniformity throughout the liquid medium.
Rounded corners for better water circulation, improved uniformity and easier cleaning.
Foam in placed PUF insulation for improved temperature stability and energy efficiency.
316 stainless steel construction for resistance against chemicals and simplified cleaning.
Long-life heating elements for quick response to controller.
Attractive front panel bezel for easy cleaning.
GMP model: Inner chamber is made of 0.8 mm thickness and outer is of S.S 304, 1.0 mm thickness.
NB: Specifications are subject to change without prior notice.
Operating Voltage | 230 V AC | |
Heating Power | 1250 W. | |
Protection Fuse | 10 amps. | |
Temperature | 0 to 40 °C | |
Accuracy | ± 0.2 °C |
Description
Capacity (Lt.) | Power | Size | |
---|---|---|---|
20 Lt. | Electric | 300 x 300mm = 12â x 12â | |
20 Lt. | Non Electric | 300 x 300mm = 12â x 12â | |
25 Lt. | Electric | 300 x 380mm = 12â x 15â | |
25 Lt. | Non Electric | 300 x 380mm = 12â x 15â | |
35 Lt. | Electric | 350 x 380mm = 14"x15" | |
35 Lt. | Non Electric | 350 x 380mm = 14"x15" |
Capacity (Lt.) | Size | |
---|---|---|
40 litres | (12â x 22â) | |
60 litres | (14â x 25â) | |
75 litres | (16â x 24â) | |
95 litres | (18â x 24â) | |
180 litres | (22â x 30â) |
Material | : | STAINLESS STEEL |
Model | : | Horizontal |
Switches | : | Processor based switches for blower, LED light & UV light With LCD back light display. (UV light with Timer) |
Pre-filter | : | 99.00% down to 5 micron. |
HEPA Filter | : | 99.97%-99.99% down to 0.3 micron, Mesh guard for protection. |
Airflow | : | Frontward Horizontally |
Noise Level | : | 60 decibel ± 5%. |
Velocity | : | 0.35-0.50m/sec. |
Work Table | : | Made up of stainless steel 304gr. Cock for gas on work table. |
Side Panels | : | 6mm±.5mm thick acrylic sheet. |
Front door | : | Made of acrylic. |
UV Lamp | : | 15/30W, make Philips Holland, |
Illumination | : | LED White Light. |
Pressure | : | Digital Manometer 0-50mm range with filter failure alarm. |
Power Supply | : | 230V ± 10V/50 Hz single phase A.C. |
Cabinet | : | 304 grade. Stainless Steel. |
Heavy Duty Blower | : | Dynamically balanced with 0.25 HP Electric Motor Mounted on anti vibration pad 1440 RPM motor. |
Covers entire visible range: | Excellent detection sensitivity | |
Compact and efficient: | Bright red seven segment LED display | |
Occupies low bench space: | Precise analysis of Flurophors & Quinine |
Fluoro Sensitivity: | Full-scale deflection obtained with 1 ppm quinine sulfate in 0.1 N sulphuric acid (primary wavelength 360 nm) | |
Display: | 3 digits bright red seven segments LED display | |
Excitation Source: | 12V, 50W Tungsten Halogen Lamp | |
Sensitivity Range: | Adjustable in 4 ranges | |
Detector: | Highly sensitive wide range photodiode/cell | |
Sample Test Tube Size: | 15 mm (D) x 80 mm (H) | |
Minimum Sample: | 4 ml | |
Power: | 230 V ± 10%, 50 Hz. AC | |
Dimension: | 260 x 335 x 160 mm (Approx.) |
Capacity (Lt.) | Size | |
---|---|---|
23 litres | (10â x 18â) | |
40 litres | (12â x 22â) | |
52 litres | (14â x 22â) | |
60 litres | (14â x 25â) | |
75 litres | (16â x 24â) | |
95 litres | (18â x 24â) | |
180 litres | (22â x 30â) |
Specification | : | Hot air oven, 2 shelves |
---|---|---|
Technical Specifications | : | |
Inside Body | : | Stainless Steel |
Out Side Body | : | MS Powder coated with stove enamel paint. (SS body also available) |
Number of Selves | : | 2 Adjustable Perforated Selves. |
Body Structure | : | Double Walled structure filled with glass wool insulation |
Number of Heaters | : | 2 x 1000 Watts |
Heater Quality | : | High Quality Chrome Heater insulated with ceramic beads |
Air Circulation | : | By Air Circulating Fan to ensure even temperature distribution. |
Ventilation | : | Ventilation port with adjustable Opening. |
Temperature Control | : | By Digital Temperature indicator and Controller |
Temperature Display | : | Digital Temp. display |
Range of Temperature | : | Ambient to 250ÂșC |
Accuracy | : | 0.10C |
Least Count | : | 1.0C |
Power | : | 220 Volt AC 50 Hz. Single Phase |
Sizes available are | : | 12" x 12" x 12" (28 Ltr.)14" x 14" x 14" (45 Ltr.)18" x 18" x 18" (95 Ltr.)24" x 24" x 24" (224 Ltr.) |