Description
Free Force Vortex Apparatus
DESCRIPTION:-
The experimental set up consist of a circular transparent cylindrical tank in which four circumferential jets have been placed along the circumference of the cylinder near its bottom which helps in the formation of free vortex. It is assumed that the torque exerted by these jets is negligible. The Orifice is reducing bush so that a reduced diameter can be investigated. The plate can also be rotated with the help of a variable speed motor so that the cylinder rotates about its vertical Axis with the help of a V belt and forced vortex is formed. Conditions wear allowed to steady state and the depth of flow at any particular point was observed not to change over a period of time. The experimental procedure involves measurement of resulting free surface that represents the variation of the sum of the pressure and datum head.
SCOPE OF EXPERIMENTS:-
Ø To plot the surface profile of a free and forced vortex by measurement of the surface profile coordinates and to show that total energy is constant throughout vortex.
TECHNICAL SPECIFICATION: –
Ø Cylinder : Material Acrylic Dia. 200mm approx
Ø Height of Overflow point : 150mm
Ø Drive : FHP variable speed motor, speed way
Ø The whole Set-up is well designed and arranged in a good quality painted Structure
Related products
Venturimeter Orificemeter Calibration Set Up
DESCRIPTION:-
The apparatus consists of two pipelines emerging out from a common manifold. One pipeline contain a Venturimeter, second contains an Orifice. The pressure tapings from the Venturimeter and Orificemeter are taken to differential manometer to measure pressure difference. The Venturimeter and Orificemeter are connected in parallel and anyone of them can be put in operation by operating valves provided at the downstream. These valves can also regulate the flow. Present Set-up is self contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different floe rate. Flow rate of water is measured with the help of measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To determine the Co-efficient of discharged through Venturimeter and Orificemeter Ø To measure discharge through Venturimeter and Orificemeter as flow meters.UTILITIES: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATIONS: –
Ø Venturimeter : Material Clear Acrylic, Compatible to 1” Dia pipe Ø Orificemeter : Material Clear Acrylic, Compatible to 1” Dia. Pipe Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank, Capacity 25 Ltrs. Ø Sump Tank : Capacity 50 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø Tanks will be made of Stainless Steel Ø The whole Set-up is well designed and arranged in a good quality painted StructureImpact Of Jet On Vanes Apparatus
DESCRIPTION:-
The Set-up consists of two sided clear fabrication. Water is fed through a nozzle and discharged vertically to strike a target carried on a stem, which extends through the cover. A weight carrier is mounted on the upper end of the stem. The dead weight of the moving parts is counter balanced by a compression spring. The vertical force exerted on the target plate is measured by adding the weights supplied to the weight pan until the mark on the weight pan corresponds with the level gauge. A total of two targets are provided a flat plat and a hemispherical cup.EXPERIMENTS:-
Ø To measure the force developed by a jet of water impinging upon a different targets (Hemispherical & Flat Plate) and comparison with the forces predicted by the momentum theory.UTILITIES REQUIRED: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Test Plates : Material Brass (2 Nos.) 1. Flat Plate 2. Hemispherical Cup Ø Nozzle : Material Brass Ø Stainless Steel Chamber : Having of opposite sides made of glass Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank with Piezometer,Capacity 40 Ltrs. Ø Sump Tank : Capacity 60 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted StructureBernoulli S Theorem Apparatus
DESCRIPTION:-
The Set-up is designed to verify Bernoulli’s Theorem experimentally. Set up consists of a one piece clear acrylic test section with convergent and divergent part section, supply tank, measuring tank, inlet water tank and pump for closed loop water circulation. The test section is connected to Piezometer tubes through pressure tapping at different locations on the section to demonstrate the Bernoulli’s Theorem. The flow rate of water is measured using measuring tank and stop watch provided.EXPERIMENTS:-
Ø To verify Bernoulli’s Theorem experimentally.FEATURES:-
Ø Clear test section Ø Closed loop water circulation Ø Compact & stand alone setup Ø Stainless Steel tanks and wetted parts Ø Superb Painted structure Ø Simple to operate & maintainUTILITIES REQUIRED: –
Ø Electricity Supply: Provide 230 +/- 10 VAC, 50 Hz, Single Phase electric supply with proper earthing (Neutral – Earth voltage less than 5 VAC) 5 A, three pin socket with switch for pump Ø Water Supply : Tap water connection ½ “ BSP, Distilled water @ 60 Ltrs. (Optional)TECHNICAL SPECIFICATION: –
Ø Test Section : Material Acrylic, Size Ø Inlet Tank : Capacity 20 Liters., Stainless Steel Ø Supply Tank : Capacity 70 Liters., Stainless Steel Ø Measuring Tank : Capacity 20 Ltrs. Fitted with Piezometer Tube & Scale Ø Piezometer Tubes : Material P.U. Tubes (9 Nos.) Ø Pump : FHP Capacity make Tullu/Crompton Graves Ø Piping : GI / PVC Size BSP Ø Stop Watch : Electronic Ø The whole Set-up is well designed and arranged in a good quality painted Structure.Reynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |