Description
Error: Contact form not found.
The Set-up consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.
Ø To determine the losses due to fiction in pipes
Ø To determine the friction factor for Darcy Weis back equation
Ø Water Supply & Drain
Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kW
Ø Pipes (2 Nos.) : Material GI of ½ “ & 1” Diameter
Ø Pipe Test Section : Length 1 m
Ø Water Circulation : FHP Pump, Crompton / Sharp make
Ø Flow Measurement : Using Measuring Tank with Piezometer,Capacity 25 Ltrs.
Ø Sump Tank : Stainless Steel, Capacity 50 Ltrs.
Ø Stop Watch : Mechanical / Electronic
Ø Control Panel : On / Off Switch, Mains Indicator etc.
The whole Set-up is well designed and arranged in a good quality painted Structure
Description
TECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |
Error: Contact form not found.