Description
Venturimeter Orificemeter Calibration Set Up
DESCRIPTION:-
The apparatus consists of two pipelines emerging out from a common manifold. One pipeline contain a Venturimeter, second contains an Orifice. The pressure tapings from the Venturimeter and Orificemeter are taken to differential manometer to measure pressure difference. The Venturimeter and Orificemeter are connected in parallel and anyone of them can be put in operation by operating valves provided at the downstream. These valves can also regulate the flow. Present Set-up is self contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different floe rate. Flow rate of water is measured with the help of measured with the help of measuring tank and stop watch.
EXPERIMENTS:-
Ø To determine the Co-efficient of discharged through Venturimeter and Orificemeter
Ø To measure discharge through Venturimeter and Orificemeter as flow meters.
UTILITIES: –
Ø Water Supply & Drain
Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kW
TECHNICAL SPECIFICATIONS: –
Ø Venturimeter : Material Clear Acrylic, Compatible to 1” Dia pipe
Ø Orificemeter : Material Clear Acrylic, Compatible to 1” Dia. Pipe
Ø Water Circulation : FHP Pump, Crompton / Sharp make
Ø Flow Measurement : Using Measuring Tank, Capacity 25 Ltrs.
Ø Sump Tank : Capacity 50 Ltrs.
Ø Stop Watch : Electronic
Ø Control Panel : On / Off Switch, Mains Indicator etc.
Ø Tanks will be made of Stainless Steel
Ø The whole Set-up is well designed and arranged in a good quality painted Structure
Related products
Pilot Static Tube Set Up
DESCRIPTION:-
A Pitot tube is used to measure the local velocity at a given point in the flow stress. A Pitot tube of standard design made of copper / SS is supplied and is fixed below Vernier scale. The Vernier scale is capable to measure the position of Pitot tube in transparent pipe section. The pipe has a flow control valve to regulate the flow. A U-tube manometer is provided to determine the velocity head. Present Set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To find the point velocity at the center of a tube for different flow rates of water and calibrate the Pitot tube Ø To plot velocity profile across the cross section of pipeUTILITIES: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Pitot Tube : Material Copper/SS of compatible size fitted with Vernier Scale Ø Test Section : Material Clear Acrylic, Compatible to 1” Dia. Pipe Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank, Capacity 40 Ltrs. Ø Sump Tank : Capacity 70 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted StructureReynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |
Reviews
There are no reviews yet.