Catheterization Trainer Simulator trainer, male bladder catheterization procedures can be realistically demonstrated, practiced and assessed.
The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.
The material is soft and flexible:
the foreskin is movable and the penis can be stretched.
This way the student can practice all the necessary gestures for catheterization (e.g. disinfection).
The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.
Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.
Various levels of difficulty:
On the male insert, three different levels of prostate narrowing can be set.
In the narrowest case, the student can feel that catheterization is no longer possible through the urethra and that a suprapubic catheter will have to be inserted.
A suprapubic catheter has already been put in place and the student can practice cleaning it and taking care of it with the trainer.
All the benefits of the male catheterization simulator at a glance:
Male catheterization with realistic resistance
3 levels of adjustable prostate narrowing soft and movable foreskin (for practicing disinfection, for example)
Anatomically realistic pelvic structure
Liquid outflow if catheterization is successfully carried out
The transparent bladder can be checked and the abdominal wall can be removed
Includes suprapubic catheter for practicing, cleaning and caring for it.
Stands securely on the table thanks to the non-slip feet
Magnetic connectors for quick set-up and dismantling
Easy to clean and maintain, and can be completely taken apart
A sponge on the inside prevents a build-up of moisture.
This model of Advanced Surgical Suturing Leg allows the students to practice cut, suturing, stitches release, enswathing, etc.
The elasticity and flexibility of skin can make it for practice hundreds of times.
There are some initial wounds on the arm and if all the initial wounds have been sutured, people can cut the arm in other place for new training of suturing.
This model provides prostates with tumors in 4 different development periods.
The 1st development:
Beginning, a little big but the prostates still works well.
The 2nd development:
Some hard tubers can be served in the top right quadrant of prostate.
It's the beginning of the tumors.
The 3rd development:
The tumor is proliferating, and the previous tubers become bumps.
The 4th development:
The prostates is all replaced by tumors, the surface become more rough and harder than before.
With the female catheterization trainer, female bladder catheterization procedures can be realistically demonstrated, practiced and assessed.
The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.
The material is soft and flexible:
the foreskin is movable and the penis can be stretched.
The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.
Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient.
The catheter can also be checked through the transparent bladder.
The abdominal wall can be removed so that the process can be viewed better.
Includes suprapubic catheter:
If it is no longer possible to carry out catheterization through the urethra, a suprapubic catheter can be inserted.
On the PRO version, a suprapubic catheter has already been put in place, and the student can practice cleaning it and taking care of it with the trainer.
All the benefits of the female catheterization simulator at a glance:
Female catheterization with realistic resistance
Soft and movable labia (for practicing disinfection, for example)
Anatomically realistic pelvic structure
Liquid outflow if catheterization is successfully carried out
The transparent bladder can be checked and the abdominal wall can be removed.
Includes suprapubic catheter for practicing, cleaning and caring for it.
Stands securely on the table thanks to the non-slip feet
Magnetic connectors for quick set-up and dismantling
Easy to clean and maintain and can be completely taken apart
A sponge on the inside prevents a build-up of moisture
The Difficult Airway Management Simulator offers a realistic airway management training with 24 various difficulty levels including 3 different mouth openings, 2 neck flexibility options, 2 positions for the vocal codes and an inflatable tongue.
Training Skills:
Airway opening techniques (head tilt, jaw thrust)
Bag-Valve-Mask ventilation
Pre intubation airway assessment
"Sniffing position"
Pressurization of external larynx to improve the laryngeal view
Intraoral/intranasal intubation
Use of oropharyngeal airway (OPA)
Use of nasopharyngeal airway (NPA)
Use of laryngeal mask airway
Use of video laryngeal scope
Use of tracheal intubation scope
Confirmation of successful ventilation by thoracic and abdominal movement
Feedbacks on incorrect procedures including esophagus intubation and unilateral intubation
Securing the tube in place with tapes or Thomas endotracheal tube holder
Training Model Includes:
1 manikin
3 upper incisions
1 lubricant
1 50ml syringe
Size: 27.6 x 15.4 x 9.9 in
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees
Fetal baby may be placed in normal, breech, or transverse position
Fetal baby cradled between two “cushions”
Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy
The Palpation Module is designed to be used with the Advanced Childbirth Simulator.
The model basing on the mechanism of normal labor shows the cardinal movements of engagement.
Descent-flection-internal rotation of the head-extension-retitution-external rotation of the head-internal rotation of the shoulders at accouchement.
Suitable for teaching the mechanism of normal labor in medical colleges and nursing schools.
Reviews
There are no reviews yet.