The model is suitable for central venipuncture of internal carotid vein and subclavical vein and peripheric venipuncture (arm veins) of cephalic vein.
The cervical veins and arm veins can be filled with simulative blood.
Features:
The model is a simulative right half of adult torso with right arm.
There are apparent anatomical marks: clavicle suprasternal notch, stenocleidomastoid muscle, pectoralis major muscle, ribs and deltoid muscle.
Lifelike veins: Superior vena cava, internal jugular vein, subclavical vein, cephalic vein, basilic vein and median cubital vein etc.
With apparent anatomical marks, the model can be used to train puncture and catheterization of internal carotid vein, subclavical vein, cephalic vein and heart catheterization.
The skin and veins can be replaced, Students will feel an apparent “POP” when puncture needle has been thrust into the veins.
The heart floating swan-ganz intubation can be exercised
The model basing on the mechanism of normal labor shows the cardinal movements of engagement.
Descent-flection-internal rotation of the head-extension-retitution-external rotation of the head-internal rotation of the shoulders at accouchement.
Suitable for teaching the mechanism of normal labor in medical colleges and nursing schools.
Interchangeable arterial and venous inserts within the fore arm allow creation of arteriovenous (AV) fistulas and placement of AV grafts, while a simulated healed fistula insert provides a platform on which hemodialysis exercises can be performed.
An additional multi-layer insert in the bicep area can be used for incision and suture training exercises.
Advanced Arterial Patient Training Arm Features:
Subcutaneous injection sites on the volar forearm and lateral upper arm
Intra Muscular injection site on the upper arm
Arterial system including the radial and brachial arteries
Suture and incision sites on both the upper arm and forearm
Hem dialysis site on the forearm
Arterial and Venous insert for IV and blood draw exercises, AV anastomosis, and placement of AV grafts. This multi-layer surgical insert includes the skin, subcutaneous tissue, muscle, radial artery, and radial vein
AV fistula insert that simulates a healed fistula for hem dialysis exercises.
Multi-layer bicep insert that includes the skin, subcutaneous tissue, and muscle and allows incision and suturing exercises
Durable skin that can be pierced in excess of 200 times with a 20 or 22 gauge needle
Realistic tactile feedback for both surgical and arterial & venous stick exercises
Adjustable heart rate and pulse strength simulating a heart rate from 10 BPM to 150BPM
Cephalic (antecubital), Basilic, Radial, and Ulnar veins as well as the radial and brachial arteries for infusion and blood draw.
Rotating arm allowing dorsal and volar access along the length of the arm.
Varying vessel palpability to simulate collapsed or bulging vessels and ease of assembly.
Latex-Free
New proprietary materials replicate of skin, subcutaneous, and muscle layers at all surgical sites.
Upgraded inserts, skins, and vessels for improved tactile feedback
Micro pump embedded within the shoulder generates variable heart rates and pulse strength.
Easy to replace plug-and-play inserts to allow quick change-out between procedures.
Latex-free vessels with improved access for hassle-free replacement.
Suturing Simulators provide a realistic way for students to learn good surgical techniques.
The simulators provide students with a variety of repair experiences without the constraint of time and concern for safety, which are factors with a live patient.
The simulators can be used by the student in a learning lab with an instructor or by the student individually in the clinical setting just prior to a patient experience.
They are also useful as homework teaching aids that can be signed out at night and returned the next day.
In addition to being portable, the lifelike texture allows the learner to develop a “feel” for instrument handling, tension on suture, and the advantages of one method of tying knots over another.
Includes one of each simulator:
Midline Suture Simulator
Left Mediolateral Suture Simulator
Right Mediolateral Suture Simulator
Each simulator comes with an instruction booklet and is individually boxed.
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees
Fetal baby may be placed in normal, breech, or transverse position
Fetal baby cradled between two “cushions”
Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy
The Palpation Module is designed to be used with the Advanced Childbirth Simulator.
The I.V. Injection Arm P50/1 made of silicone, is unique in quality and design and allows realistic training to teach competence to medical staff.
It is also very suitable for group instruction because of its high quality, stain resistance and easy-to-clean soft material.
It is ideal for practicing the following:
Correct puncture of peripheral veins for blood sampling.
The following veins can be punctured: basilica vein, cephalic vein, median cubital vein, dorsal venous rete of hand
Intravenous injections
Positioning of a butterfly catheter
Delivered in deluxe storage carton with:
1 injection arm with already mounted tubing system
1 infusion bottle
1 stand
1 bottle of artificial blood concentrate(250ml)
1 plastic cup
1 disposable syringe and 2 injection cannulas (recommended cannula size: 20 and 21 gauge)
2 tubing systems as replacement parts
1 container of talcum powder