This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.
This charging unit is fitted with motorised vacuum pump and other safety devices like pressure gauge. With the help of this charging unit students can charge the refrigerant gases into compressor or store the gas of a refrigerator or air conditioner inside the cylinder fitted inside the charging unit that can be used later.
In old times refrigerant gas leakage was detected with the help of soap foam but with the help of refrigerant gas leak detector we can do the same job in more professional and reliable way.
The apparatus consists of a storage water tank, embraced by evaporator coil of the cooling unit, cooling cycle comprises of a hermetically sealed compressor, air-cooled condenser, a capillary tube as expansion device and an evaporator cell. The stainless steel water tank is provided with insulation on air Sides and a door are provided at the top. Cold water can be taken out from a top provided and inlet water supply is controlled by a bail-operated top. Various measurements provided enable students to determine the theoretical and actual COP, power consumption, actual cooling capacity refrigerant flow and compressor volumetric efficiency of compressor.
SPECIFICATIONS:
Cooling Cycle
a) Compressor Hermetically sealed type, having the capacity of 1/3 ton of refrigeration using R-12 refrigerant.
b) Finned tube type air colled condenser with forced air flow.
c) Filter cum drier for refrigerant.
d) Capacity expansion device.
e) Evaporator coil embraced on stainless steel water tank, Provided with glass wool Insulation.
2.Water drain tap and float operated inlet water tap are provided for water tank with insulated lift door at top.
3.Measurement
a) Pressure gauges for evaporating and condensing pressure.
b) Thermometers to measure refrigerant temperatures at inlet and out let of condenser and evaporator.
c) Dial type thermometer for water temperature.
d) Rotameter to measure liquid refrigerant flow.
e) Energymeter to measure compressor Input.
4.Safely & Controls –
a) Thermostat to put off compressor at set water temperature.
b) Pressostat to put off compressor if high or low pressure Goes out of set limit.
c) Over load protector for compressor,
A technical manual will be supplied along – with the unit. Also, the unit is provided with an attractive and anti corrosion powder costing.
SERVICES REQUIRED:
1.Floor space of 1.5 m. X 1.5 m.
2.Water supply of 5 lit/min,
3.230 V, 15A AC stabilized supply with earthing connection
Refrigeration & Air Conditioning Tool Kit (Set Of 20)
This tool kit is a set of twenty tools used in refrigeration & air conditioning. With the help of this tool kit students can learn how to operate these tools & also understand there applications.
This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.
The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. cooling coil). Measurements of various parameters Torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning.
SPECIFICATIONS:
1.Cooling circuits – It consists of:
a) Hermetic compressor, having the capacity of 2/3 ton of refrigeration (approx.) using R-22 refrigerant.
b) Rotameter for liquid refrigerant flow measurement.
c) Pressure gauges for high and low pressure.
d) Prescott (i.e. high and low pressure cut-out).
e) Thermometers for temperature measurement at various points In the cycle.
f) Energymeter for compressor input measurement.
g) Condensate measuring arrangement.
2.Heating Circuit – Air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 Kw.
3.Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. in which airflow is generated by axial flow fan.
4.Anemometer for measurement of air velocity, (range 0-15 m/sec. Following experiments can be conducted on the unit
a) Cooling of atmospheric air.
b) Heating of atmospheric air.
c) Humidification of atmospheric air.
d) Dehumidification and heating of atmospheric air.
(Cooling coil acts as dehumidifier at reduced airflow.)
SERVICES REQUIRED:
1.440 V, 15 A, 3 Phase supply with earthing connection.
2.Floor space area about 3 m. X 2 m.
Reviews
There are no reviews yet.