One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees
Fetal baby may be placed in normal, breech, or transverse position
Fetal baby cradled between two “cushions”
Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy
The Palpation Module is designed to be used with the Advanced Childbirth Simulator.
Lymphatic system model showing the different function of lymphatic system.
Relief model, approx. 2/3 natural size.
Model in one piece.
On a base plate.
Height: 84 cm., width: 54 cm., depth: 12 cm., weight: 10 kg
Catheterization Trainer Simulator trainer, male bladder catheterization procedures can be realistically demonstrated, practiced and assessed.
The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.
The material is soft and flexible:
the foreskin is movable and the penis can be stretched.
This way the student can practice all the necessary gestures for catheterization (e.g. disinfection).
The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.
Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.
Various levels of difficulty:
On the male insert, three different levels of prostate narrowing can be set.
In the narrowest case, the student can feel that catheterization is no longer possible through the urethra and that a suprapubic catheter will have to be inserted.
A suprapubic catheter has already been put in place and the student can practice cleaning it and taking care of it with the trainer.
All the benefits of the male catheterization simulator at a glance:
Male catheterization with realistic resistance
3 levels of adjustable prostate narrowing soft and movable foreskin (for practicing disinfection, for example)
Anatomically realistic pelvic structure
Liquid outflow if catheterization is successfully carried out
The transparent bladder can be checked and the abdominal wall can be removed
Includes suprapubic catheter for practicing, cleaning and caring for it.
Stands securely on the table thanks to the non-slip feet
Magnetic connectors for quick set-up and dismantling
Easy to clean and maintain, and can be completely taken apart
A sponge on the inside prevents a build-up of moisture.
The I.V. Injection Arm P50/1 made of silicone, is unique in quality and design and allows realistic training to teach competence to medical staff.
It is also very suitable for group instruction because of its high quality, stain resistance and easy-to-clean soft material.
It is ideal for practicing the following:
Correct puncture of peripheral veins for blood sampling.
The following veins can be punctured: basilica vein, cephalic vein, median cubital vein, dorsal venous rete of hand
Intravenous injections
Positioning of a butterfly catheter
Delivered in deluxe storage carton with:
1 injection arm with already mounted tubing system
1 infusion bottle
1 stand
1 bottle of artificial blood concentrate(250ml)
1 plastic cup
1 disposable syringe and 2 injection cannulas (recommended cannula size: 20 and 21 gauge)
2 tubing systems as replacement parts
1 container of talcum powder
The model is suitable for central venipuncture of internal carotid vein and subclavical vein and peripheric venipuncture (arm veins) of cephalic vein.
The cervical veins and arm veins can be filled with simulative blood.
Features:
The model is a simulative right half of adult torso with right arm.
There are apparent anatomical marks: clavicle suprasternal notch, stenocleidomastoid muscle, pectoralis major muscle, ribs and deltoid muscle.
Lifelike veins: Superior vena cava, internal jugular vein, subclavical vein, cephalic vein, basilic vein and median cubital vein etc.
With apparent anatomical marks, the model can be used to train puncture and catheterization of internal carotid vein, subclavical vein, cephalic vein and heart catheterization.
The skin and veins can be replaced, Students will feel an apparent “POP” when puncture needle has been thrust into the veins.
The heart floating swan-ganz intubation can be exercised
For Continuous Ambulatory Peritoneal Dialysis.
Designed to introduce patients, students, and nurses to the essentials of CAPD procedures and care.
The realistic torso offers a realistic method to demonstrate and practice peritoneal dialysis.
Success with CAPD is dependent on the patient’s following dialysis procedures with extreme care.
This Life/form simulator gives the patient an opportunity to gain the confidence necessary for prolonged success with CAPD.
Complete with indwelling Tenckh off catheter in a hard carry case.
Dialysis materials not included.
This model provides prostates with tumors in 4 different development periods.
The 1st development:
Beginning, a little big but the prostates still works well.
The 2nd development:
Some hard tubers can be served in the top right quadrant of prostate.
It's the beginning of the tumors.
The 3rd development:
The tumor is proliferating, and the previous tubers become bumps.
The 4th development:
The prostates is all replaced by tumors, the surface become more rough and harder than before.
The model basing on the mechanism of normal labor shows the cardinal movements of engagement.
Descent-flection-internal rotation of the head-extension-retitution-external rotation of the head-internal rotation of the shoulders at accouchement.
Suitable for teaching the mechanism of normal labor in medical colleges and nursing schools.