To determine the co-efficient of absolute expansion of mercury.
Glass tubes with vertical limbs contained within glass jackets approx.
460 x 25 mm height x diameter are closed by bungs and fitted with inlet and outlet tubes.
Upper ends of these vertical limbs are angled on emergence from the jackets to produce two short, adjacent limbs placed against a silvered glass scale 0 to 12 cm x 1 mm.
Mounted on stand 610 x 230 mm, height x width.
Overall height 750 mm approx.
supplied without mercury.
Consisting of a joint less copper calorimeter 75 x 50 mm on rubber supports, spun outer copper vessel of 100 x 75 mm diameter copper lid for outer vessel with central tubule for thermometer and slit for copper stirrer with a looped copper stirrer for the inner vessel.
Copper calorimeter of 75 x 50 mm resting on felt pad inside wooden polished box provided with a brass nickel plated thermometer holder and copper stirrer.
Demonstrates the difference in thermal conductivity of two different materials.
The kit consists of two identical blocks, one made of aluminum and other made of plastic.
When an ice cube is placed on aluminum it turns into water in seconds, while on plastic block it melts slowly.
The aluminum block has a larger heat capacity and a higher thermal conductivity while the plastic block has lower values of both parameters.
With instructions.
Two cast metal uprights, height 18 cm, fitted with two nickel plated rods supporting expansion bar of length 38 cm.
Expansion bar is fixed to one upright and moves a pointer on the other, when heated With scale reading 0 to 90°, supplied with one each, aluminium, brass and iron expansion bars.
Comprising two castmetal uprights linked by a pair of parallel plated metal support rods and supporting an expansion bar at the top. Supplied with expansion bars.
Comprising two cast-iron uprights, height 18 cm linked by two nickel plated rods supporting on expansion bar, length 38 cm fixed to one upright and resting on a friction pointer placed at the other.
Supplied with scale reading 0 to 90 deg and one each of aluminium, brass and iron expansion bars.
A 500 mm long metal rod is supported in a plated brass tube with three tubules for steam inlet, outlet and thermometer.
The tube is mounted on a stand with an adjusting screw at one end and a micrometer screw reading to 0.01 mm on the other, with terminals for connecting a bell or galvanometer to indicate contact.
With copper, brass and iron test rods but without thermometer.
To illustrate expansion of metal on heating and contraction on cooling, with steel bar of length 100 x 10 mm and plated brass gauge with a cutout to just accommodate the bar and two holes through which the bar passes when cold.
To determine co-efficient of expansion of a gas at constant pressure.
A glass U-tube with a bulb and stopcock at one end, the other limb being open.
An outlet tube from the bottom of the U tube passes through a rubber bung and has a stopcock at the end.
The stem below the bulb is graduated 3 x 0.1 ml. An inlet tube with a mohr clip also passes through the bung.
A glass water jacket encloses the U tube.
All glass parts made of borosilicate glass requires only 20 ml mercury, which is not included.