A 500 mm long metal rod is supported in a plated brass tube with three tubules for steam inlet, outlet and thermometer.
The tube is mounted on a stand with an adjusting screw at one end and a micrometer screw reading to 0.01 mm on the other, with terminals for connecting a bell or galvanometer to indicate contact.
With copper, brass and iron test rods but without thermometer.
To observe heat transfer under different conditions by measuring the temperatures of the insulated containers before and after connecting them with the metal bar.
Consists of two insulated containers, two thermometers and a metal bar and instruction manual.
Specially designed for metal block calorimeters.
Heating element enclosed in a metal tube with two connecting leads which are insulated with heat resistant insulation. 12 V, 50 W.
Apparatus is fitted on heavy channel base, at one end of which is an adjusting screw, at the opposite end is a micrometer screw reading to 0.01 mm for measuring the expansion.
Supplied with one each of aluminium, brass and iron expansion rods but WITHOUT thermometer.
Consisting of metal rod 500 mm in length and 4.5 mm dia.
enclosed in a well - lagged, metal tube with three tubules for steam inlet, outlet and thermometer.
The metal rod to be investigated is supported in the steam jacket by detachable rubber bungs situated at each end of the tube.
Two cast metal uprights, height 18 cm, fitted with two nickel plated rods supporting expansion bar of length 38 cm.
Expansion bar is fixed to one upright and moves a pointer on the other, when heated With scale reading 0 to 90°, supplied with one each, aluminium, brass and iron expansion bars.
Comprising two castmetal uprights linked by a pair of parallel plated metal support rods and supporting an expansion bar at the top. Supplied with expansion bars.
Comprising two cast-iron uprights, height 18 cm linked by two nickel plated rods supporting on expansion bar, length 38 cm fixed to one upright and resting on a friction pointer placed at the other.
Supplied with scale reading 0 to 90 deg and one each of aluminium, brass and iron expansion bars.
Nickel plated copper calorimeter of 50 x 75 mm lagged and enclosed in an outer vessel of 75 x 100 mm size, with cover having terminals, a heating coil suitable for 3 – 6 V supply and holes for thermometer and stirrer.
With stirrer but without thermometer.
Copper calorimeter 75 x 50 mm with felt insulation, outer vessel of 100 x 65 mm size with a plastic lid having holes for thermometer and stirrer.
A thermometer holder is fixed to the outer vessel. Complete with stirrer.