XTEMOS ELEMENT

AJAX PRODUCTS TABS

Featured
  • Featured
  • Accessories
  • Furniture

Co-Ordinate Board

A very common task in math class is to plot and name points on what we call the co-ordinate board, more commonly known as a four-quadrant graph. We offer coordinate board game with color counters and dice to understand this difficult maths topic in the form of game. This article shows you the steps for plotting and nameing points on a co-ordinate board. Board measure: 38cm x 38cm. Set of 4 dice & 50 counters.

Human Biology Microslide Set

This set has been assembled to provide a range of microslides suitable for use in Biology and Human Biology course. Set of 24 slides consisting of
Artery and veinBone, TS
Colon, TSEye, VS
Human blood smearJoint, LS
Kidney, LSKidney, VS triple stain
Lung, TS thin sectionMyelinated nerve fibers
Nerve Cells from spinal cordOesophagus, TS
OvaryPhagocytosis in lung
Plantar skin, VS sweat glandsScalp, hair insertion, sebaceous glands
Small intestineSmooth muscle
Spinal Cord TSStomach, TS
Striated muscle, teasedTestis
Tongue, VSTrachea, TS

Acrylic Light Demonstration Cube

Description

To demonstrate refraction and provides a better understanding of Snell’s Law. Comprises of acrylic cube and a glass mug. Includes instructions.
XTEMOS ELEMENT

AJAX PRODUCTS TABS SIMPLE

shirt-tab
Fashion
Featured
  • Featured
  • Man
  • Woman

Variable Inductor

Description

The enamelled wire winding and a cylindrical soft iron core are built into this unit. The iron core displacement inside the winding can manually adjusted by the knob to give precise measurements up to 1.3 H. Connections are made through 4 mm sockets.

Specifications:

Resistivity: 0.0165 W/m; Inductance: 0.15 to 1.3 H; Voltage: 30 V AC or 60 V DC.

Intestinal Villi

Description

100 times enlarged model with one entire villus, one longitudinally sectioned villus showing the arterioles and venules and one cut villus to show the lymphatic vessels with enlarged representation of a longitudinal section of Lieberkuhn’s crypt.

Distillation Plant (Manasty Type), Wall Hanging

The unit is recommended for making pyrogen fee distilled water of a very high degree of purity, Made out of S.S. special kettle element is fitted with Ejection Device / Auto cut for safety of the element is provided water supply is stopped. The cork fitted to the unit is of brass C.P.A. wall Mounting clamp is provided with the unit. Supplied with cord and plug to work on 220/240 volts A.C. Stainless Steel, Output approx. 3/4 Ltr./Hr. Stainless Steel, Output approx. 5/6 Ltr./Hr. Aluminium Dicasted, Output approx. 3/4 Ltr./Hr. Aluminium Dicasted, Output approx. 5/6 Ltr./Hr.

Siemens IoT 2020 Gateway

Specification:

• SimaticIoT 2020 Educational Intelligent gateway • Intel Quack Soc x 1000 • 400MHz operating frequency • Micro SD card slot, upto 32GB • 512MB RAM, 8MB Flash, 256KB SRAM • One USB controller and one USB device • FTDI USB to serial Interface • One no of 10/100Mbps Ethernet • Arduino Uno R3 compatible expansion slot • One mini PCIe expansion slot for WLAN/additional Ethernet port • Yocto V2.1 based Linux operating system • Input supply 24V DC • Programming in high level language • Support for various protocols like Modbus RTU, POC UA and cloud protocols like MQTT/AMQP
XTEMOS ELEMENT

AJAX PRODUCTS TABS ALTERNATIVE

Fashion
Featured
  • Featured
  • Man
  • Woman

Manual Steering System

Steering System – Actual Working Manual Steering System The working of steering system is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of steering system are shown in actual working form. This model helps the student to understand the working of the steering system very easily. It is specially made dissectible for demonstration purposes.

Mammals

Description

All Charts are made on PVC rexine, hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wal, Size 75×100 cm. Rat External Development Rat General Anatomy Rat Digestive system Rat Male Reproductive system Rat Female Reproductive system Rat Arterial system Rat Venous system Rat Nervous system Rat Respiratory system Rat Skeleton Rat Brain, different views Rat Heart, different views Rabbit External Development Rabbit General Anatomy Rabbit Digestive system Rabbit Male Reproductive system Rabbit Female Reproductive system Rabbit Arterial system Rabbit Venous system Rabbit Nervous system Rabbit Respiratory system Rabbit Skeleton Rabbit Brain, different views Rabbit Heart, different views

Light Box and Optical Set

Description

A Robust light box in matt black finish with a 12 V 24 W axial filament lamp with flexible leads. One end of the box takes a cylindrical convex lens in an adjustable sliding mount to enable production of convergent, parallel or divergent beams. Complete with accessories which consist of: 5 Plastic blocks, one rectangular, One semicircular, One equilateral prism 60° x 60° x 60°, One right angle prism 90° x 60° x 30° and one right angle prism 90° x 45° x 45°. 3 Cylindrical acrylic lenses: one double convex, one double concave, both having the same radius of curvature and one thick convex lens. 3 Mirrors, one plane glass, one curved parabolic and one curved semi-circular. 2 Slit plates, one with three narrow and one narrow slits, the other with four narrow and one wide slits 1 Set of eight colour filters, Red, Green, Blue, Cyan, Violet, Yellow, Orange and Magenta. 1 Set of coloured cards, Red, Green, Blue, Violet, Orange, Cyan, Yellow and Pink. Complete with one spare lamp, in box.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ARROWS PAGINATION

shirt-tab
Electronics
Featured
  • Featured
  • Mobile
  • Smartwatches

Concentric Tube Heat Exchanger

(A)Plain Tube ( Water To Water ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. While the outer tube consists of GI pipe through which cold water flows. The arrangement enables the parallel and counter flow of the cold water. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D, 12.7mm. and outer G. I. Pipe I. D. 15mm. approx. and 1.5m. length. 2.Thermometers – 4 nos. 3.Measuring flask – 1 Lit. capacity. 4.Geyser-3 kW. Single phase.

Services required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x I m x 1 m height. (B) Finned Tube ( Water To Air ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. It is finned at its outer diameter to increase the heat transfer surface. While the outer tube consists of GI pipe through which cold air flows. The arrangement enables the parallel and counter flow of the air. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D. 12.7mm. and outer G. I. Pipe I. D. 25mm. approx. and 1m. length. 2.Thermometers – 4 nos. 3.Orifice meter along with manometer. 4.Measuring flask – 1 Lit. Capacity. 5.Geyser-3 kW. Single phase.

Services Required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x 1m x 1m height.

Unit Cubes

Interlinking Cubes are one of the most widely-used math manipulative in the world. The colorful, interlocking cubes help children to learn number and math concepts. These cubes represent units and link in all direction. Interlinking cubes are used for patterning, grouping, sorting, counting, numbers, addition, subtraction, multiplication, division and measurement. Each unit is a cubic centimeter measuring 1 cm x 1 cm x 1 cm

Advanced Surgical Suture Arm

Description

Interchangeable arterial and venous inserts within the fore arm allow creation of arteriovenous (AV) fistulas and placement of AV grafts, while a simulated healed fistula insert provides a platform on which hemodialysis exercises can be performed. An additional multi-layer insert in the bicep area can be used for incision and suture training exercises.

Advanced Arterial Patient Training Arm Features:

Subcutaneous injection sites on the volar forearm and lateral upper arm Intra Muscular injection site on the upper arm Arterial system including the radial and brachial arteries Suture and incision sites on both the upper arm and forearm Hem dialysis site on the forearm Arterial and Venous insert for IV and blood draw exercises, AV anastomosis, and placement of AV grafts. This multi-layer surgical insert includes the skin, subcutaneous tissue, muscle, radial artery, and radial vein AV fistula insert that simulates a healed fistula for hem dialysis exercises. Multi-layer bicep insert that includes the skin, subcutaneous tissue, and muscle and allows incision and suturing exercises Durable skin that can be pierced in excess of 200 times with a 20 or 22 gauge needle Realistic tactile feedback for both surgical and arterial & venous stick exercises Adjustable heart rate and pulse strength simulating a heart rate from 10 BPM to 150BPM Cephalic (antecubital), Basilic, Radial, and Ulnar veins as well as the radial and brachial arteries for infusion and blood draw. Rotating arm allowing dorsal and volar access along the length of the arm. Varying vessel palpability to simulate collapsed or bulging vessels and ease of assembly. Latex-Free New proprietary materials replicate of skin, subcutaneous, and muscle layers at all surgical sites. Upgraded inserts, skins, and vessels for improved tactile feedback Micro pump embedded within the shoulder generates variable heart rates and pulse strength. Easy to replace plug-and-play inserts to allow quick change-out between procedures. Latex-free vessels with improved access for hassle-free replacement.
XTEMOS ELEMENT

AJAX PRODUCTS TABS WITH ICONS

Furniture
  • Furniture
  • Lighting
  • Accessories
  • Clocks
  • Cooking

COPLIN JAR FOR 5 SLIDES

PRODUCT DESCRIPTION: This popular staining jar has heavy glass walls and a broad base for increased stability. It holds five single 3" x 1" (75 mm x 25 mm) slides vertically, or 10 slides back to back, and requires low reagent volume (approximately 65 mL). Manufactured from soda-lime glass. Approximate inside dimensions: 26 mm L x 26 mm W x 90 mm D.

Human molar Teeth

This model illustrated the structure of the molar teeth , also show the capillary vessel and nerve. Size(cm): 16x20x32

Polishing Pan

Features

Inner Dia 12 x8" high with opening of 7" Dia neck. Detachable polishing pan for use with Tablet Coating Pan. Made Of M.s. Provided With Inner Lining Of Superior Canvas Cloth.
XTEMOS ELEMENT

AJAX PRODUCTS TABS LOAD MORE PAGINATION

Featured
  • Featured
  • Lighting
  • Accessories

SILICA CRUCIBLE WITHOUT LID

PRODUCT DESCRIPTION
  • Crucible is glazed inside and outside.
  • Highly resistant to alkalis and hot temperatures
  • 50ml capacity
  • Outside diameter 55mm, 42mm height
  • No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML

SILICA CRUCIBLE TALL FORM Without Lid, Translucent

PRODUCT DESCRIPTION -Without lid, translucent, glazed - Ordinary type lids to be purchased separately Size/ dimension:
  • 20ml,  Dia. 35mm x Ht. 38mm
  • 30ml, Dia. 43mm x Ht. 38mm
  • 50ml, Dia. 51mm x Ht. 51mm

SILICA MUFFLE TRAYS (For VM Crucible)

PRODUCT DESCRIPTION:   Available in 2types:  Two Hole, 39mm Length Four Hole, 76mm Length
XTEMOS ELEMENT

AJAX PRODUCTS TABS CAROUSEL

Featured
  • Featured
  • Cooking
  • Furniture