Hydraulic Linear Actuation System Trainer with Labview Interfacing
Features
• This trainer helps to learn the characteristics of double acting cylinder namely direction, speed & force. • A Microcontroller ADC relay driver provided to actuate the cylinder. • Gear pump supplies the hydraulic fluid to double acting cylinder through direction control valve. • Pressure control valve controls the flow rate of fluid to cylinder. • Single phase induction motor drives the pump. • Control unit communicate with PC and controls the double acting cylinder using LabVIEWSoftwares. • Two proximity sensors are provided to indicate the position of the cylinder. • Load cell measures the force developed by the cylinder. • 5/2 Double Solenoid Valve directs the cylinder. • One tank is used to store the hydraulic fluid.Bottle Stand for 6 bottles
Spherometer Laboratory
Spherometer Laboratory
• Brass dial head 40 mm diameter, mounted on stainless steel screw.
• Head divided into 100 divisions, reading to 0.01 mm and registering on vertical scale 10-0-10.
• Frame with three legs of stainless steel.
• Distance between two legs is 40 mm approximately.
• Pitch 1mm.
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Theramal Conductivity Of Insulating Slabs
The apparatus consists of a slab assembly. The main Heater and a radial guard heater are sandwiched between copper plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other Sides of the specimen. The radial guard heater ensures all heat of the main heater to pass axially through the specimens which is collected by cooling plates. By knowing the temperatures and Heat input, thermal conductivity of specimen can be calculated. The test set up is enclosed in an enclosure with insulation inside to provide undisturbed Surroundings. The design style of the apparatus is similar to as recommended in INDIAN standard. The difference is in sizes.
SPECIFICATIONS:
1.Heaters: a)Main heater plate 110 mm dia. with mica heater Sandwiched between copper plates. b)Radial guard heater plate I.D. 120mm and OD 200 mm mica heater sandwiched between copper plates. 2.Water circulated cooling plates -2 nos. 3.Dimmerstat-2 A capacity – 2 nos. to independently control Inputs to the heaters. 4.Measurements – A voltmeter and an Ammeter with selector switches to measure inputs,Multichannel digital temperature indicator to measure Temperatures at various points, having 0.1 °c least count. A technical manual accompanies the unit.SERVICES REQUIRED:
1.230 V, A.C. stabilized supply along with earthing connection. 2.Water supply of about 4-5 lit/min. 3.Bench area 1m x lm x O.5m height.Rotary Shaker (Platform Type)
Body made out of thick mild steel finished with powder coating.
Heavy duty PMDC motors for suitable capacities are provided for long time, continuous operation.
Fixed speed and variable speed models are offered.
Platform is provided RPM range-upto 250 RPM, electronic control, 0-60 min timer.
Workable on 220 V AC 50Hz single phase.
Optional
Digital R.P.M. indicator. Digital timer (0-99 min.).Platform size in cm | Holding capacity | |
---|---|---|
45x45 mm | 25 flasks of 100 ml | |
45x45 mm | 36 flasks of 50 ml | |
45x45 mm | 16 flasks of 250 ml | |
55x55 mm | 25 flasks of 50 ml | |
65x65 mm | 36 flasks of 250 ml | |
105x105 mm | 81 flasks of 50 ml | |
105x105 mm | 64 flasks of 250 ml |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Thin Cylinder Apparatus
A heavy bench top unit for studying the stress and strain in a thin walled cylinder under internal pressure. A thin walled cylinder is mounted between two support blocks. Internal pistons and seals create oil sealing. A handwheel at one end of the apparatus enables the cylinder end conditions to be adjusted to either open or closed. The internal pressure is adjusted by means of a hydraulic hand pump on the apparatus. An analogue pressure gauge displays the internal pressure whilst a pressure transducer gives feedback to the Data Acquisition Interface and Software supplied. Strain gauges are arranged on the external surface of the cylinder to measure the radial and circumferential surface strain. The strain gauges are at various angles.
Calorimeter copper
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Single Phase Cyclo Converter
Specification
• Consists of firing circuit, SCR power circuit and load. • Line synchronized IC based linear firing circuit. • Line synchronization achieved by step - down transformer. • Four nos. firing pulse with pulse transformer isolation to trigger four SCR. • One no. potentiometer used to vary the firing angle (180° - 0°). • Carrier logic implemented with carrier frequency of 4KHz. • One no. toggle switch with debounceogic for pulse ON/OFF. • EPROM Based firing pulse frequency variation. • Two nos. toggle switch to select different frequency (Hz, 50/2Hz, 50/3Hz, 50/4Hz). • Power circuit consists of Four nos. SCR with fuse protection. • Anode, Cathode, Gate terminals are terminated in the front panel for user connection. • 24V AC, 1Amp Provided for power circuit input with ON/OFF switch. • One no. fixed R, load provided Center tapped inductor for power circuit. • 230V, 50Hz AC input with ON/OFF rocker switch, fuse for over load.4 Stroke 1 Cylinder Diesel Engine Manual Driven
The engine will be sectioned to show the internal constructional details. The working of individual part and accessories like Valves, Pistons, pumps, Crank and Camshaft, etc. will be demonstrated. It is provided with Flywheel and it is mounted on a sturdy iron frame. This actual cut section engine helps the student to understand about the parts and the working of the engine very easily. It is specially made dissectible for demonstration purposes. The actual cut section engine will be supplied with key card & very interesting literature regarding working.
Model AC DC Generator
Impact Of Jet On Vanes Apparatus
DESCRIPTION:-
The Set-up consists of two sided clear fabrication. Water is fed through a nozzle and discharged vertically to strike a target carried on a stem, which extends through the cover. A weight carrier is mounted on the upper end of the stem. The dead weight of the moving parts is counter balanced by a compression spring. The vertical force exerted on the target plate is measured by adding the weights supplied to the weight pan until the mark on the weight pan corresponds with the level gauge. A total of two targets are provided a flat plat and a hemispherical cup.EXPERIMENTS:-
Ø To measure the force developed by a jet of water impinging upon a different targets (Hemispherical & Flat Plate) and comparison with the forces predicted by the momentum theory.UTILITIES REQUIRED: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Test Plates : Material Brass (2 Nos.) 1. Flat Plate 2. Hemispherical Cup Ø Nozzle : Material Brass Ø Stainless Steel Chamber : Having of opposite sides made of glass Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank with Piezometer,Capacity 40 Ltrs. Ø Sump Tank : Capacity 60 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted StructureXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Fisher Clamp
We bring to you, Fisher Clamp.
The Fisher Clamps are moulded in Polypropylene making it completely corrosion-proof.
The spring-loaded jack in the middle provides a vice like grip to the Burette and prevents it from slipping.
Two tapered wedges are provided to ensure firm grip on rods having diameter ½" or 3/8".
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Fisher Clamp- Single | 12 | |
Fisher Clamp- Double | 6 |
Polarimeter
Description
Suitable for determining specific rotation of optically active substances. It has Laurent’s quartz half shade device which make the system sufficiently accurate and at the same time simple, suitable for use with sodium light. The circular head is attached to the analyzer. Vernier movable over the scale enables reading 0-360° or 0-180°. A 200 mm tube is provided with the instrument. Mounted on a sturdy tripod stand.Digital Bomb Calorimeter
DIGITAL BOMB CALORIMETER
Bomb Calorimeter outfit provides a simple and inexpensive method for determination of heat of combustion of organic matter and the calorific value and sulphur content of solid and liquid fuel. The outfit supplied is complete for analysis as per the method recommended by British Standard Institution BS 1016. All parts of the outfit have been finished of petroleum and British Standard Institute.SUPPLIED WITH
Calorimeter Vessel with bomb support, Water jacket, Combined Lid for calorimeter vessel and water jacket, Stirrer, Connecting Leads, Connecting tube to connect bomb & pressure gauge, Connecting tube with fine adjustment valve, to connect pressure gauge, pressure gauge on stand, Spanner for oxygen tube connection, Ignition Wire, (2 meters) Nichrome, Cotton Real, stand for bomb lid, Hook for lifting bomb, stainless steel Crucible, Gelatine capsules, Gas release valve, Bomb firing unit, Vibrator, Timer, Benzonic acids. ‘O’ Ring Big, ‘O’ Ring Small, ‘O’ Ring for Stirrer Valve for Bomb, Valve Kay. Complete with Instruction manual.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT