XTEMOS ELEMENT
AJAX PRODUCTS TABS
ABELS FLASH POINT APPARATUS
DESCRIPTION
Suitable for determination of close cup flash point determination of Petroleum and petroleum products having flash points below 70º C.
It comprises of test flame arrangement, oil cup, cover fitted with shutter mechanism, oil test jet or gas test jet, stirrer, water bath arrangement- temperature controlled by energy regulator and stand.
The unit is workable at 220 V AC supply.
OPTIONAL
Electrically Driver Stirrer with a FHP Motor having flexible shaft.
Spare Oil Cup Thermometer (-35ºC to 70ºC)
Water Bath Thermometer (-30ºC to 80ºC)
Transaxle Gear Box With Differential
Transaxle Gear Box With Differential – 4 Forward & 1 Reverse Actual Cut Section
The working of gear box is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of gear box are shown in actual working form. This model helps the student to understand the working of the gear box very easily. It is specially made dissectible for demonstration purposes.
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Pressure Process Station
Panel Features
• Digital Panel Meters. • Mimic diagrams. • Pressure gauges are provided, wherever necessary.Softwares
• MATLAB • LabVIEW • PLC • C/VB CompatibilityFeatures
• The Pressure process station is an attractive module comparing to the Analyzer and Laboratory trainer. • All are the industrial standard (4-20)mA interfacing signals. • It provides a real industrial feeling of the process to the students. • A Piezo Resistive Pressure Transmitter (0-7)Bar is used to sense the pressure. • An Electronic Regulated Power supply is fixed for voltage Regulation. • An electro pneumatic converter is mounted to control the pneumatic control valve. • A globe Pneumatic Control Valve for controlling flow of air. • An air regulator cum filter is provided for Air regulation. • A two separate pressure tank is provided as process tank with pressure gauges and relief valves. • All the air flow lines are fitted by flexible hoses/fittings for better reliability. • Hand valve provisions are given for series, parallel connection of pressure tanks. • USB/Serial port data acquisition is provided.Porous Pot
Construction of Parabola
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Animal Cage
Description
Made of iron S.S frame provided with thick iron mesh on sides. Hinged door on front. Provided with water bottle and feeding tray. Extra drawer provided in the base for collection of excreta. Well painted for elegant looking Feeding arrangement allows removal of bin from outside of cage with automatic drop closure. Size 30x23x30cm Size 45x45x38cmDecade Inductance Box – 3 Dial
Electropneumatic Training
LIST OF EXPERIMENTS
1.Intoduction of Relay and Contactor. 2.Introduction of Proximity Sensor, Capacitive & Photoelectric Sensor, Limit Switch. 3.Introduction to Pressure Switch, Electrical Counter, ON Timer & OFF Timer. 4.Operation of single acting cylinder with single sol. valve and single limit switch. 5.Operation of double acting cylinder with single sol. valve and single limit switch. 6.Continuous operation of double acting cylinder with single solenoid valve and two limit switches. 7.Operation of double acting cylinder with single solenoid valve, AND gate of electrical switches. 8.Operation of double acting cylinder with single solenoid valve, OR gate of electrical switches. 9.Operation of double acting cylinder with single solenoid valve, NOR gate of electrical switches. 10.Operation of double acting cylinder with single solenoid valve, NAND gate of electrical switches. 11.Operation of double acting cylinder with double solenoid valve. 12.System pressure will be maintained in specified pressure limit with pressure switch. 13.Operation of double acting cylinder with single solenoid valve with ON time delay. 14.Operation of double acting cylinder with single solenoid valve with OFF time delay. 15.Continuous operation of double acting cylinder with specified no. of cycles using Counter. 16.Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Both Cylinder retracts simultaneously. A+, B+, (A-, B-). , Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Cylinder A retracts then Cylinder B retracts. A+, B+, A-, B-SALIENT FEATURES
1.Self combined mobile unit. 2.Only electrical supply required. 3.All the components are easily accessible. 4.Real life components of reputed manufacturers provided. 5.Quick connections possible due to special fittings/pipes. 6.Tried and tested components and circuits. 7.Specially designed electrical control panel enabling students to develop their own electrical circuits. 8.Completely user friendly and highly interactive software provided with PC based Trainer. 9.Modular design with facilities to operate simple mechanisms. 10.Pneumatically operated models available as additional supply. 11.Training of Trainers offered at regular intervals. 12.Two years performance guarantee for any manufacturing defects.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Rotary Pipette Stand
Moulded in Polypropylene, the unique Rotary Pipette Stand holds a maximum of 94 pipettes and rotates on a central vertical axis for convenient selection of any particular pipette.
The lower rotating disc has four concentric troughs with tapered sides and open bottoms that cradle the pipette tips protectively and permit water drops to run off.
The upper disc has a grid pattern concentric with the bottom disc and keeps the pipettes vertical.
Liquids draining off the pipettes are retained on the top of the stationary base by the outer ring.
Our Rotary Pipette Stand can be easily disassembled and reassembled.
Particulars | Pack (Pcs) | |
---|---|---|
Pipette Stand (Rotary) - For 94 pipettes | 1 | |
Pipette Box | 4 |
Friction In Pile Lines Apparatus
DESCRIPTION:-
The Set-up consists of 2 pipes of different diameters, which are connected in parallel. Pressure tapings are provided on each pipe to measure the pressure losses with the help of a Differential Manometer. Control valves are fitted on each pipe, which enables to use one pipe at a time for experiment. Present set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To determine the losses due to fiction in pipes Ø To determine the friction factor for Darcy Weis back equationUTILITIES REQUIRED: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Pipes (2 Nos.) : Material GI of ½ “ & 1” Diameter Ø Pipe Test Section : Length 1 m Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank with Piezometer,Capacity 25 Ltrs. Ø Sump Tank : Stainless Steel, Capacity 50 Ltrs. Ø Stop Watch : Mechanical / Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. The whole Set-up is well designed and arranged in a good quality painted StructureStop Clock, Mechanical
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Ria Vial
These Polypropylene/Polystytene tubes are generally used in RIA , Coagulation & Bacteriology.
The Polypropylene tubes are clear and can withstand 3000 RCF during Centrifugation while the transparent Polystyrene tubes can withstand 1400 RCF.
The PP tubes can accept common acids, alkalis & solvents at room temperature while the PS tubes can accept mild bases, weak acids but not organic solvents.
Material : Polypropylene / Polystyrene
Particulars | Pack (Pcs) | |
---|---|---|
RIA Vail 12 x 75 mm / PS | 500 | |
RIA Vail 12 x 75 mm / PP | 500 | |
Cap For 12 mm RIA Tube | 100 |
Pulse Width Modulation and Demodulation
This Instrument is design to demonstrate the method to transmit signals via. Electromagnetic transmission and to study the Pulse Width Modulation and Demodulation. Whole instrument is placed in plastic moulded box and 2 mm banana plug leads are provided for modulation and demodulation connections.
Technical Specification:-
1. Built in IC based DC Regulated Power supply ±12 V, +5 V.
2. Four level Built in carrier pulse Output.
3. Frequency Range: 8 KHz, 16 KHz, 32 KHz, 64 KHz Amplitude : 5 Vpp approx.
4. Built in sine wave Audio Frequency Function Generator for modulating signal. Frequency Range: 1 KHz and 2 KHz selectable with a toggle switch Amplitude : 0-10 Vpp and 0-4 Vpp approx.
5. Circuit Diagram for Modulation and Demodulation is printed on the milky white top panel.
SILICON RUBBER CORK
PRODUCT DESCRIPTION
A Bung, Stopper or Cork is a truncated cylindrical or conical closure to seal a container such as bottle, tube or barrel. Unlike a lid, which encloses a container from outside without displacing the inner volume, a bung is partially inserted inside the container to act as a seal. These can be used for all types of glass bottles. These stoppers fit tightly to prevent chemical leaks. We are one of the very few manufacturers of silicone rubber corks, septa gasket, silicone rubber stoppers in India.
Features:
- Silicon rubber cork / stopper /bung,
- Silicon rubber cork for filtration flask.
Natural Convection Apparatus
The unit consists of a vertical brass pipe heated by a cartridge heater inside it. The pipe looses heat to atmosphere by natural convection. It is fitted in an enclosure to provide undisturbed natural convection currents. Thermocouples are attached on the pipe to measure local temperatures. Heater input is measured on voltmeter and ammeter. Thus students can determine overall heat transfer coefficient and local transfer coefficients in natural convection at various heat transfer rates.
SPECIFICATIONS:
1.Pipe – Brass pipe, 38mm. dia. (OD) 500mm. long, fitted with cartridge heater inside. 2.Thermocouples are fitted along with the length of pipe for Temperature measurement – 7 nos. 3.Enclosure 200mm. x 200mm. x 800mm. size, with one side of Perspex sheet. 4.Measurements & Controls a) A Dimmerstat for heater input control. b) Voltmeter and Ammeter for heater input measurement. c) Multichannel digital temperature indicator. A technical manual accompanies the unit.SERVICES REQUIRED:
1.Bench area of 1.5m x 0,75m. at working height. 2.230v, 5A, AC, electric supply with earthing connection.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT