XTEMOS ELEMENT
AJAX PRODUCTS TABS
Peripherally Inserted Central Catheter
Description
The model is suitable for central venipuncture of internal carotid vein and subclavical vein and peripheric venipuncture (arm veins) of cephalic vein. The cervical veins and arm veins can be filled with simulative blood.Features:
The model is a simulative right half of adult torso with right arm. There are apparent anatomical marks: clavicle suprasternal notch, stenocleidomastoid muscle, pectoralis major muscle, ribs and deltoid muscle. Lifelike veins: Superior vena cava, internal jugular vein, subclavical vein, cephalic vein, basilic vein and median cubital vein etc. With apparent anatomical marks, the model can be used to train puncture and catheterization of internal carotid vein, subclavical vein, cephalic vein and heart catheterization. The skin and veins can be replaced, Students will feel an apparent “POP” when puncture needle has been thrust into the veins. The heart floating swan-ganz intubation can be exercisedResistance Coil, Economy
CAVITY BLOCK
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Storage Vial (Internal Thread)
We provide high quality range of Storage Vial.
An addition to the range of storage vials, is this vial which has internal thread in it.
The cap fitted with O-ring screws in to the vial and makes it a leak proof storage vial.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Storage Vail - Internal Thread 2.0 ml | 500 |
Unsymmetrical Bending Apparatus
DESCRIPTION:
Apparatus consist of an angle of size 1” x 1” x 1/8” or in equivalent metric units of length 80cm is tied as a cantilever beam. The beam is fixed at one end such that the rotation of 450 intervals can be given and clamped such that the principal axis of its cross-section may be inclined at any angle with the horizontal and vertical planes. Also arrangement is provided to apply vertical load at the free end of the cantilever and to measure horizontal and vertical deflection of the free end. A dial gauge with magnetic base is supplied with the apparatus.EXPERIMENT MANUAL:
• To study the behavior of a cantilever beam under symmetrical and unsymmetrical bending. • Using a Dial gauge shown a increasing and decreasing of heights.Citical Radius Of Insulating Material
Citical Radius of Insulating Material:
At particular radius of insulation over a cylinder, loss of heat is maximum. The unit consists of a G.I. pipe provided with plaster of Paris insulation on out side surface. Four pipes are provided with heater inside having input control. Input to heaters is measured by common voltmeter and ammeter, by controlling input to heaters, it is shown that critical radius of insulation is ratio of thermal conductivity and outside heat transfer co-efficient.
SPECIFICATIONS:
1.G. I. Pipes with electrical heater inside – 4 Nos. 2.Insulation over the pipes of different thickness. 3.Controls and Measurements – a) Dimmerstat to control heater input – 4 Nos. b) A voltmeter and ammeter to measure inputs to heater. c) Digital temperature indicator to measure temperatures across insulation. d) Necessary switches and controls. A technical manual accompanies the unit.SERVICES REQUIRED:
230 V, 5 Amp., A.C., Supply with earthing connection. Floor Area of 1 m. X 1 m X 1.5m. height.Platinum Resistance Thermometer
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Digital Colorimeter
Description
The basic set-up of the colorimeter is: LED light source: Produces polychromatic light over the entire visible region, 45 Broad spectrum filter: The colorwheel has nine different filters. The filter employed is selected by wavelength. Each filter will produce monochromatic light at a specified peak wavelength with a bandpass of 20 mm. The filters enable the user to perform tests from 400 to 680 nm. Cuvette Holder: It holds the inserted cuvette during testing. It is imperative the cuvette be consistently oriented in the holder. Round cells usually have orientation markings to correctly position the cuvette. Detector: A silicon photo diode is used as the detector. The photo detector current will change as a function of light energy. Display:The current signal from the detector is converted to a numerical value, absorbance and is shown on led displaySpecimen Jar
We have come up with a quality range of Specimen Jars.
These transparent Specimen Jars are used for preserving different specimens in the lab and are provided with a cap that fits in tight.
These jars provided excellent protection to the species preserved in it.
Material : Polystyrene
Particulars | Pack (Pcs) | |
---|---|---|
Specimen Jar (Gas Jar) | 12 |
Frequency Response Analysis of Lead Lag Network
Frequency response of Lead, Lag network using P+I+D controller is a special purpose analog simulation, create using operational amplifiers. This simulator permits a detailed analysis of the first order and second order systems on the application of proportional, integral and derivative control to the improvement of their performance. The simulator may be used at high frequency for oscilloscope observation.
FEATURES:
• Built-in Function Generator (sine & square). • Self contained power supplies and power ON/OFF switch with indication. • Full mimic diagrams in the front panel. • The simulated process. - Simple Lag Process - Simple Lead Process • The simulated PID controller - Integral controller scaled in Integration time. - Derivative controller scaled in derivative action time. - Proportional band control scaled in % proportional band (PB).Abney Level Made of Brass pipe
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Storage Vial
These polypropylene vials add to the existing range of Polylab storage vials.
Available in 5 ml. & 10 ml. capacities, these vials have polypropylene cap with built in seal ring which makes it a leak proof vial.
These vials are also used for the storage of biological material, animal & human cells etc.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Storage Vail 2.0 ml | 500 | |
Storage Vail 5.0 ml | 500 | |
SV - 10 ml | 500 | |
SV - 5 ml | 500 |
Leopold Maneuvers Simulator
Description
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees Fetal baby may be placed in normal, breech, or transverse position Fetal baby cradled between two “cushions” Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy The Palpation Module is designed to be used with the Advanced Childbirth Simulator.Level Control Measurement Module
This module consists of a process tank with a miniature pump, level sensor for 2 levels, a power supply, etc., To establish a ON/OFF control for the level of water. Circuitry is provided for stand alone operation or through a 8255 port of a Microprocessor kit.
Specification
• A transparent tank of height 150mm with adjustable electrodes to vary the high level and low level. • A pump with tank for water circulation • Water level can be monitored under software control/automatic mode • One power relay 230V/6Amp for pump ON/OFF control • Miniature connectors are provided to operate as stand alone controller or through software under a Microprocessor trainer. • Built in power supply.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Linear Expansion Apparatus, Micrometer Screw Form
Description
A 500 mm long metal rod is supported in a plated brass tube with three tubules for steam inlet, outlet and thermometer. The tube is mounted on a stand with an adjusting screw at one end and a micrometer screw reading to 0.01 mm on the other, with terminals for connecting a bell or galvanometer to indicate contact. With copper, brass and iron test rods but without thermometer.Heart With Artery Blockage Models
Insect Box with Stretching Strips
Description
Suitable for taking in field where the insects can be stretched on the spot and can securely be kept inside the box Teakwood frame with melamine lamination on top & MDF sheet bottom is nicely polished. Top & bottom lined with EVA sheet over which adjustable strips provided for stretching insects. Strips can be fixed at one place with fine screws and fly nuts. Fitted with brass hinges, index card holder, clips and handle. Size Approx. 43 x 30 x 11cm.Refractive Index of Water Apparatus
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT