Plain Laboratory Desiccator
We offer premium range of Plain Laboratory Desiccator which can be availed at market leading price range. Plain Desiccator have excellent quality and durability.
Grease should be applied on the flanges to make it air tight.
Material : Polypropylene/ Polycarbonate
Particulars | Pack (Pcs) | |
---|---|---|
Desiccator (Plain) PP/PC 150 mm | 1 | |
Desiccator (Plain) PP/PC 200 mm | 1 | |
Desiccator (Plain) PP/PC 250 mm | 1 | |
Desiccator (Plain) PP/PC 300 mm | 1 |
Electrophoresis Horizontal
Description
With rich industry experience and support of highly skilled quality experts our organization is engaged in providing a wide range of Electrophoresis Horizontal Mini-GEL that is commonly used for carrying out number of analytical tests by separating DNA and RNA on the basis of shape, size, and electrical affinity. It is offered with platinum electrodes that are almost hundred percent pure. We also provide gel casting tray, one comb with a terminal lead.Features:
Easy maintenance Precision-designed Flawless functioningSix Phase Power Analyzer
Specification
• 6 phase measurement @ 50Hz • 6 voltage inputs (250V AC max., 50Hz) & 6 AC current inputs (5A max) • Zero crossing output for both voltage and current waveforms • 6Nos of phase sensing circuits provided to measure the phase difference of 2 waveforms • Signal Conditioning for Torque & Speed (QEP, Proximity, Optical) • After Signal Conditioned, 6 voltage outputs, 6 current outputs, 12 zero crossing outputs & 6 phase sensing outputs are terminated at 34 pin and 26 pin FRC connectors • Power input through banana sockets • Housed in a sleek cabinetXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Ball & Ring seperate
Balance Weights
Polished brass, supplied with wooden block, as illustrated.
• Capacity 500 gm. Comprising 1x200 gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5 gm, 2x2 gm, 1x1 gm
• Capacity 1000 gm. Comprising 1x500 gm, 1x200 gm, 2x100 gm, 1x50 gm, 1x20 gm, 2x10 gm, 1x5 gm, 2x2 gm, 1x1 gm.
• Capacity 2000 gm. Comprising 1x1000 gm, 1x500gm, 1x200gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5gm, 2x2gm, 2x2gm, 1x1gm.
Thermistor Unit
Blood Bank Rrefrigerator
Features
Temp Range/Precision : 4 ±1°C, 0.1 °C Control System : Microprocessor control Display Alarm : Large screen LED display/ Audio and visual alarm for Height or low temperature; System failure; Door ajar; Power failure Refrigeration Type : Forced air refrigeration system Door : Three-ply transparent glass door with lock, Heating film preventing frosting, Stealing joint strip with magnetic force Casters : 4 casters Power Supply : 110/220V±10%, 50/60Hz Capacity : 120L Refrigerant : R134a, CFC-Free Material Internal : Stainless steel Material External : Cold-rolled steel with anti-bacteria powder coating Drawers/Shelves : Shelves Consumption : 160W External Size(L*W*H) : 520*600*1050mm Standard Accessory : Temperature printer, 2 shelves, 6 baskets, fluorescent lightSpecifications
Temperature- 2°C to 4°C Temperature Accuracy- + / - 1°C Temperature Controller- Digital P.I.D Controller Display- LCD / LED Display Alarm- Audio visual alarm for high and low temperature. Power Failure Alarm- Yes Refrigerant- Non-CFC Refrigerant Defrost type- Automatic Air Circulation- Forced air circulation External Construction- Stainless Steel 304 grades / MS Power Coated Interior Construction -Stainless steel 304 Insulation- CFC free high density polyurethane foam insulation Shelves- Adjustable and made of quality steel wire Illumination- Fluorescent Lamp Safety Device- High and low temperature protection Power Supply - 220 VoltsXTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Breeding Nest
Expansion Model of Human Teeth
Electropneumatic Training
LIST OF EXPERIMENTS
1.Intoduction of Relay and Contactor. 2.Introduction of Proximity Sensor, Capacitive & Photoelectric Sensor, Limit Switch. 3.Introduction to Pressure Switch, Electrical Counter, ON Timer & OFF Timer. 4.Operation of single acting cylinder with single sol. valve and single limit switch. 5.Operation of double acting cylinder with single sol. valve and single limit switch. 6.Continuous operation of double acting cylinder with single solenoid valve and two limit switches. 7.Operation of double acting cylinder with single solenoid valve, AND gate of electrical switches. 8.Operation of double acting cylinder with single solenoid valve, OR gate of electrical switches. 9.Operation of double acting cylinder with single solenoid valve, NOR gate of electrical switches. 10.Operation of double acting cylinder with single solenoid valve, NAND gate of electrical switches. 11.Operation of double acting cylinder with double solenoid valve. 12.System pressure will be maintained in specified pressure limit with pressure switch. 13.Operation of double acting cylinder with single solenoid valve with ON time delay. 14.Operation of double acting cylinder with single solenoid valve with OFF time delay. 15.Continuous operation of double acting cylinder with specified no. of cycles using Counter. 16.Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Both Cylinder retracts simultaneously. A+, B+, (A-, B-). , Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Cylinder A retracts then Cylinder B retracts. A+, B+, A-, B-SALIENT FEATURES
1.Self combined mobile unit. 2.Only electrical supply required. 3.All the components are easily accessible. 4.Real life components of reputed manufacturers provided. 5.Quick connections possible due to special fittings/pipes. 6.Tried and tested components and circuits. 7.Specially designed electrical control panel enabling students to develop their own electrical circuits. 8.Completely user friendly and highly interactive software provided with PC based Trainer. 9.Modular design with facilities to operate simple mechanisms. 10.Pneumatically operated models available as additional supply. 11.Training of Trainers offered at regular intervals. 12.Two years performance guarantee for any manufacturing defects.PIPETTE BULB
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Malu’s Law
Description
Students can investigate the relationship between the intensity of transmitted light and the angle of rotation of two polarizing filters. A graduated cartridge containing two polarizing filters allows students to observe the change in intensity as they are rotated relative to one another. The analyzer allows quantitative readings to be taken using a voltmeter at five degree intervals as the polarizing filters are rotated from minimum to maximum transmission. The output from the analyzer changes linearly with light intensity and so the resulting data can be used to verify Malus Law. Includes instructions.Lagged Pipe Apparatus
Lagged Pipe Apparatus:
The apparatus consists of three concentric pipes mounted on suitable stand. The space between innermost and the middle pipe is fifed with a lagging material and the space between the middle and the outer most is filled with and other lagging material. The lagged pipe is heated with a cartridge heater inserted at the axle length of the pipe. Voltmeter and ammeter on the panel can measure the input to the heater. The intermediate temperatures can be measured by the thermocouples attached at the surfaces of the pipe. Thus the resultant conductivity of the materials can be found out.
SPECIFICATIONS:
1.Pipes : a)Gl pipe (innermost) – 6 cm. (Outer Diameter). b) Gl Pipe (Middle) – 8.5 cm. (Mean Diameter) c)G! Pipe (Outermost) – 10.7 cm. (inner Diameter) d)Length of pipes 1 Meter. 2.Heater : Nichrome wire cartridge heater placed centrally, of suitable capacity. 3.Control Panel : a)Single Phase Dimmerstat – 1 No. b)Voltmeter (0 – 250V) – 1 No. c)Ammeter (0- 2A) – 1 No. 4.Temperature Indicator : Multichannel Digital Temperature Indicator ranging (0 – 300 C) using Cr/AI ThermocouplesServices Required:
1. A.C. Single Phase 230 V electric supply 2. Floor Area-1.5 Meter X 1 Meter X 0.5 Meter HighMoving Coil Meters
Description
Meters are designed for D.C. measurements to meet every need of schools, colleges and technical institutions. All meters are housed in moulded dust proof cases with zero-adjuster and have connections terminals. Type MO-65 Round.Case | : | ABS Plastic | |
Accuracy | : | Class 2.5 | |
Scale length | : | 50 mm. | |
Overall size | : | 100x90x90 mm. approx. |
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Vortex Shaker (Test Tube Shaker)
Compact Vortex Shaker
Compact, rugged construction. Heavy metal base & rubber feet prevent movement of the shaker during use. Choice of continuous & touch mode. Variable speed control. Include one hand insert, micro tube insert & cup attachment.Product Details
Maximum speed : 3000 rpm Usage : Laboratory Capacity : 600mlLinen Tester
Description
These are collapsible pocket magnifiers. The optical system is a single element, glass Double Convex Lens. The housing is made of machined, black high grade plastic for a high finish look. These magnifiers fold flat to fit in your pocket. Scales are etched on the inner faces of the viewers base.
Human Stomach,3 Parts
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent