XTEMOS ELEMENT
AJAX PRODUCTS TABS
Signal Generator, Digital
This signal generator is a useful test instrument capable of generating multiple waveform and offers excellent waves shape, signal linearity, waveform symmetry and frequency range with selection of sine, triangular and square wave and amplitude variable 10 V peak to peak. 1 Hz to 100 kHz in five decade ranges selected by rotary switch named as frequency multiplier. Sine, triangular and square waveforms selected by push switch with LED indication. Output signal is 0 – 3.5 Vrms (10 V peak to peak) open circuit continuously control with uncalibrated amplitude control knob. Mains rocker switch with indicator Light. Signal Generator is versatile for general laboratory use; output signal is adjustable with the combination of frequency multiplier and set frequency dial with a low level of distortion. Set frequency is displayed on a 4 seven segment display. Output Voltage is continuously variable with selector range 1 V and 10 V.There is two pair of output safety sockets. One for CRO output (experiment for amplification, filter etc.) and another pair of sockets to speaker to drive a speaker and to demonstrate the audio signal frequency range 20 Hz to 20 KHz.
Post Office Box, Wheatstone Bridge
Description
With two ratio dials of 10,100 and 1000 ohms each and a resistance arm of four dials, each of ten coils of 1, 10, 100 and 1000 ohms, giving total resistance of 11,110 ohms with 4 mm socket terminals for battery, galvanometer and unknown resistance. Highly stable resistances are used. Accuracy ±0.1%Linear Expansion
Description
Apparatus is fitted on heavy channel base, at one end of which is an adjusting screw, at the opposite end is a micrometer screw reading to 0.01 mm for measuring the expansion. Supplied with one each of aluminium, brass and iron expansion rods but WITHOUT thermometer. Consisting of metal rod 500 mm in length and 4.5 mm dia. enclosed in a well - lagged, metal tube with three tubules for steam inlet, outlet and thermometer. The metal rod to be investigated is supported in the steam jacket by detachable rubber bungs situated at each end of the tube.Line Ranger
Description
Our expertise enables us to develop a broad range of measuring and survey equipment and instruments such as Line Rangers. Manufactured using high grade metal and alloys, these line rangers can be availed in standard as well as customized sizes and specifications. Used for various testing and measuring activities by our clients, our range can be availed at most descent prices.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Leak Test Apparatus (S.S BODY)
Ideal instrument to check blister Packs, Strip for Leak Test.
The old method of separate desiccator and the huge vacuum pump is replaced with the new Leak Test Apparatus in GMP Stainless Steel Body with phenomenal compactness.
The instrument is equipped with Diaphragm type vacuum pump gives the higher level of vacuum in shortest possible time.
Die pressed polycarbonate vacuum desiccator sustains vacuum for a long time.
A vacuum gauge is provided to indicate vacuum level which is connected to isolation valve to disconnect the source.
Thus avoiding the need of continues running of the vacuum pump.
| Body: | Stainless steel. 304 | |
| Desiccator: | SPolycarbonate, 8” Desicator Provided with Digital Timer | |
| Timer: | S3999 sec. Digital | |
| Vacuum Level: | S 22" Hg | |
| Current: | S 5A | |
| Voltage: | S 230 |
RF Telemetry
RF telemetry system consists of a radio frequency transmitter and matching radio frequency receiver both operating at 433 MHz. The system is designed for the radio frequency transmission and reception. The radio frequency transmitter sends out a variable audio signal and the radio frequency receiver with built in loud speaker receives the signal. The system enables the teachers to demonstrate a variety of wave phenomenon. The system also enables the properties of the radio communications to be investigated and compared with those of visible light and other wave motions such as audible sound and water waves etc. For the operation of the system, a 9 V PP3 battery is required.
Chrysopa Breeding Nest
Description
Teakwood frame with silk screen net on sides and collapsible cover on side. Cover can be fixed in position with help of lever. Top sliding plank of MDF covered with black cloth from inside and spirit polished from outside. A sapre plank supplied for replacement. Combs for removal of insect from plank. Beautiful spirit polish finish. Size 60x60x30cmDissolution Rate Test Apparatus
Specification
Consist of thermostatic control water bath which maintains temp. at 37DegC with + 0.5 Deg C variations. Provided with borosilicate vessel 1000 ml, variable speed motor, cylindrical wire mesh basket & shaft with blades of stainess steel. Single Basket, (Analog) Single Basket, (Digital R.P.M) Single Basket, (Digital) Temp. & R.P.MXTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Block, Glass
Dental Care Model(With Cheek), PVC
Discrete Component Trainer
Trainer consisting of Power Supply of +5 V / ±12 V (each of 250 mA), Silicon, Germanium diodes, Zeners, PNP and NPN Transistors, FET, One speaker, 12 different values of carbon film resistances of ¼ W, ½ W and 1 W. 12 assorted values of capacitors from 100 pF to 1000 ?F, Integrated Circuit (IC) Base and IC 74LS00 1 No. each. LED, LDR, Photo diode, Solar Cell Logic Switches (4 No.) and LED Indicators (4 No.) etc., 2 mm Interconnection Leads -10 No. and Comprehensive User’s Manual
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Charle’s Law Apparatus
Description
To determine co-efficient of expansion of a gas at constant pressure. A glass U-tube with a bulb and stopcock at one end, the other limb being open. An outlet tube from the bottom of the U tube passes through a rubber bung and has a stopcock at the end. The stem below the bulb is graduated 3 x 0.1 ml. An inlet tube with a mohr clip also passes through the bung. A glass water jacket encloses the U tube. All glass parts made of borosilicate glass requires only 20 ml mercury, which is not included.Six Phase Power Analyzer
Specification
• 6 phase measurement @ 50Hz • 6 voltage inputs (250V AC max., 50Hz) & 6 AC current inputs (5A max) • Zero crossing output for both voltage and current waveforms • 6Nos of phase sensing circuits provided to measure the phase difference of 2 waveforms • Signal Conditioning for Torque & Speed (QEP, Proximity, Optical) • After Signal Conditioned, 6 voltage outputs, 6 current outputs, 12 zero crossing outputs & 6 phase sensing outputs are terminated at 34 pin and 26 pin FRC connectors • Power input through banana sockets • Housed in a sleek cabinetStacking Counters
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
CNC Lathe Trainer With Servo Drives
CONTROLLER:
(1) Type of control system: PLC based system (2) Main Spindle Drive : AC Motor with VFD (3) Z and X Drives : Stepper drive with RAMP function (4) Input to Stepper Motor : Optically Isolated (5) Motor Drive :TTL Compatible (6) Run Speed Control : Computer controlled through software (7) Interpolation : Liner / Circular / Parabolic (8) Cycles Used :G,M,S,T,F,I,K,M,F (9) Cycles : Circular Interpolation / Canned (10) Threading : Straight / Taper (11) Power Devices : Short Circuits and over Temperature Protected (12) Real Time Tool Path Simulation : ProvidedMACHINE DETAILS:
(1) Center height : 100mm (2) Swing over Carriage : 80mm (3) Distance between Centre : 250mm (4) Longitudinal Travel : 250mm (5) Weight : 350 kg (6) Dimension in mm : 1100 x 750 x 1700 (7) Rapid Travel : 500mm/min (8) Resolution X & Z Axis : 10micron (9) Dt. Motor Power : 40V – 4A (10) Lubrication : ManualSPINDLE:
(1) Spindle Speed : Continuous Variable (2) Spindle Power : 2 HP (3) Inside Taper : MT3 (4) Speed Range : 50 to 3000RPMBio-Agent Cage Acrylic
Clinometer Compass
Description
Clinometer Handle Compass is a reproduction of an antique Clinometer compass. The Handle Compass gets its name from its "handle" shaped sight, which actually serves two purposes With the compass level, an object can be viewed through the peep sights to determine its magnetic heading. The second and most interesting purpose is when tilting the compass on its side and viewing an object through the sights, its angle of elevation or declination can be found. A weighted pendulous arm beneath the compass needle can be read from one of three scales : Angle in degrees beneath the zenith (from straight up), angle in degrees of elevation or declination, and in inches per yard of slope. The compass has a needle lift mechanism to protect the compass jewel and the pendulous arm when being transported.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT