XTEMOS ELEMENT
AJAX PRODUCTS TABS
Process Control Simulator
The process control simulator is a special purpose analog simulator with operational amplifiers The simulator permits a detailed analysis of the first order, second order and third order systems and the application of proportional, integral and derivative control to the improvement of their performance. The simulator may be used at high speed for oscilloscope observation or at a low speed for meter observation.
FEATURES:
• Built-in Function Generator (Sine & Square wave). • Self contained power supplies and power ON/OFF switch. • Simulated distance-velocity lag. • Full mimic diagrams in the front panel. • The simulated process - Simple Lag of 1ms/10ms, 2 lags of time constant 1ms/10ms that can be toggled to integrators of same time constant - Distance-velocity lag & delay 10ms • The simulated PID controller - Integral action control scaled in integral action time. - Derivative action control scaled in derivative action time. - Proportional band control scaled in % proportional band.Reynold S Apparatus
DESCRIPTION:-
The Set-up is designed to verify Reynold’s Apparatus experimentally. The Apparatus consists of a glass tube which one end having bell mouth entrance connected to a water tank. At the other end of the glass tube a cock is provided to vary the rate of flow. Flow rate of water can be measured with the help of Measuring Cylinder and Stop Watch, supplied with the set-up. A capillary tube is introduced centrally in the bell mouth. To this tube dye is fed from a small container, placed at the top of Constant head Tank, through polythene tubing.EXPERIMENTS:-
Ø To study different types of flow. Ø To determine the Reynold’s Number and hence the type of floe either laminar or turbulent.UTILITIES REQUIRED: -
Ø Water Supply. Ø DrainTECHNICAL SPECIFICATION: - | ||
Ø Tube | : | Material Borosilicate Glass |
Ø Dye Vessel | : | Material SS, Suitable Capacity |
Ø Capillary Tube | : | Material Copper/Stainless Steel |
Ø Constant Head Water Tank | : | Capacity 40 Liters. |
Ø Water Circulation | : | FHP Pump |
Ø Flow Measurement | : | Using Measuring Cylinder |
Ø Sump Tank | : | Capacity 60 Liters |
Ø Stop Watch | : | Capacity 60 Liters. Electronic |
Ø Control Panel Comprises of | : | Standard make, On/Off Switch, Mains Indicator, etc. |
Ø The Whole set-up is well designed and arranged in a good quality painted structure. |
Perimeter Smith Type
Specifications
Material : Stainless Steel Color : BlackProduct Description
The perimeter is an instrument for accurate charting of the field of vision. It consists of. A vertical stand on which a metallic arc is pivoted. It also bear a circular black disc to read the meridian in which the arc in shape of a semicircle with radius 330 mm. Its rotating in any direction and fix at any position with a tightening screw. The arc is graduated from 0 to 90 with a movable test object which is a white color spot of size 10mm diameter painted on a circular disc it can be moved with arc. An adjustable chin rest and a detachable leveling bar is fixed in front of the metallic arc. A scale and circular chart frame to hold the chart paper in position is provided at the back of the circular disc. A metallic graduated scale with a movable pin-punch pointer is fixed to mark on the perimeter chart paper.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Burner Bunsen, LPG
Human Torso With Head
Description
Full size, 10 parts, without sterno – abdominal wall but with ribs, sternum and clavicle with their attachments. Thoracic and abdominal organs, individually detachable lungs, stomach, liver, intestine, heart, which is further sectioned in two parts. Half of skull cap is removed, and brain can be taken out, exposing the interior of the skull. Sectioned head and neck depicts internal organs of the region, sexless, on base, with key card.Sphygmomanometer
For measurement of systolic and diastolic blood pressure of human beings in metabolic rate.
Mercury type manometer, manually operated instrument, includes inflatable cuff-arm with Velcro, inflating rubber-bulb below with non-return air valve having captive air bleed screw, all connected through flexible rubber tubing.
Comes in a metal box.
Digital Trainer Using NAND Gates
Complete with Regulated power supply of + 5V/500 mA. Provided with 4 Logic input switches (bounceless) 4 LED Indicators (Buffered)
Functional diagram of :-
1. 3 Input NAND 6 No.
2. 4 Input NAND 4 No.
3. 1 Input NOT Gates 4 No. is printed on board.
4. 12 Interconnection Leads and User’s Manual is provided.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
VHDL/VERILOG Learning Kit
Features
• Based on 64 Macro cell Xilinx CPLD device : XC2C64A • 20 SPDT Slide switches • 16 output LEDs and One 7 segment LED display • 4x4 Matrix keys using Micro switches (4 multiplexed with 4Nos of Slide switch) • One NC/NO switch for giving manual clock • Square wave Oscillator • Onboard USB to JTAG and External JTAG Connector for programming the CPLD • 16 I/O Lines terminated at 20 pin connecter. • External 5 volt 2Amp power supply • Compatible with Xilinx ISE Design Suite Web Pack Software. • USB Cable • Onboard USB to JTAG is Compatible only with Vi JTAG 5.0 Software.4 Stroke 4 Cylinder Diesel Engine
4 Stroke 4 Cylinder Diesel Engine – Motor Driven Actual Cut Section Working Model With Valve Timing Attachment
The engine be sectioned to show the internal constructional details.The working of individual part and accessories like Valves,Pistons,pumps,Crank and Camshaft,etc.will be demonstrated.It is provided with Flyweel and it is mounted on a sturdy iron frame. This actual cut section engine helps the student to understand about the parts and the working of the engine very easily. It is specially made dissectible for demonstration purposes.The actual cut section engine will be supplied with key card & very interesting literature regarding working.
Separating Throttling Calorimeter
AIM
To find out dryness fraction of steam by combined separating and throttling calorimeter.
PRODUCT DETAILS
The steam passing out from separating calorimeter may still contain some water vapour , in it . in other words it may not be absolutely dry . again , in a throttling calorimeter steam after passing through the throttle valve must be superheated or at least dry saturated . this limits the extent of dryness fraction that can be reliably measured , depend up on the pressure of steam in the main steam pipe . if a sample of steam, which may be still wet after passing through the throttle valve i.e it will not be superheated . thus under this condition the throttling calorimeter fails to enable us in determining the value of dryness fraction of steam . to overcome this difficulties we make use of separating and throttling calorimeter . first the steam is passed through separating calorimeter where itlosses most of it’s moisture and becomes comparatively drier, it is than passed through the throttling calorimeter where super heating takes place with out changr of total heat . the temperature and pressure of steam after throttling are measured by using a thermometer and manometer respectively.DESCRIPTION
The set up consist of a separating and throttling calorimeter . a steam generator is provided at the base of the apparatus . a thermostat knob is provided at the front of apparatus to control the temperature inside the steam generator . steam from steam generator is passed from separating calorimeter where most of the water partical get separated from steam and then passed to throttling calorimeter where steam get superheated . after that superheated steam passed through heat exchanger to condense the steam.SAPARATING CALORIMETER
It consist of two concentric chamber , the inner chamber ,and the outer chamber . which communicates with each other through an opening at the top. As the steam discharge through the metal baskets ,which has a large number of holes , the water partical due to there heavier momentum get separated from the steam and collected in the chamber. The comparatively dry steam in the inner chamber moves up and than down aging through the annular space between the two chambers and enters the throttling calorimeter .THROTTLING CALORIMETER
It consist a narrow throat . pressure and temperature are measured by manometer and thermometer . the steam after throttling process passed through the heat exchanger and condensate is collected .UTILITIES REQURIED
1.WATER SUPPLY 3 lit/min (approx) 2.Drain 3.Electric supply : 1phase , 220 V A.C , 2Amp. 4.Steam table for calculation 5.Space required : 1.0 m X 1.0 mXTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

SCR Characteristics Trainer
Specification
• Basic static characteristics study trainer. • LM723 based variable DC power supply (0-30V) for SCR Vak. • LM723 based variable DC power supply (0-12V) for gate voltage of all devices. • Separate section for SCR/TRIAC characteristics. • Separate section for IGBT/MOSFET characteristics. • Two nos. fixed load resistor for all devices. • Four nos. potentiometer to vary all voltages. • LED indication for all power supply. • Three nos. digital multimeter for measurement of device parameters. • For Diac external power supply to the provided.Cytology
Description
All Charts are made on PVC rexine, hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall. Size 75×100 cm. Cell Membrane showing structure & functions Cell Wall, showing structure & functions Endoplasmic Reticulum showing structure & functions Mitochondrion – showing structure & functions Golgi Complex showing structure & functions Chloroplast – showing structure & functions Nucleus – showing structure & functions Chromosome – showing structure & functions D.N.A. – showing structure & functions R.N.A. – showing structure & functionsMasses Iron
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Automotive Stethoscope
When components of an automobile engine are not functioning properly, they usually sound a warning in the form of noises not common to normal operations. Fortunately most noises posses characteristics of their own which help to identify the sources, coupled with some knowledge of their meaning. The unit is consisting of earphone, amplifier, switch and carbon microphone, assembled in a polished wooden box, Furnished with instructions, and a chart of possible different noise, probable source, mike position and how to check.
Angel Sum Property of Quadrilateral
CALCIUM CHLORIDE TOWER 250ML
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT