XTEMOS ELEMENT
AJAX PRODUCTS TABS
Porous Pot
Steam Engine Model
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Multi-Functional Nursing Simulator (Male)
Description
Designed according to the demand of the clinical principles and the guidelines of nursing training. This multifunctional simulator could simulate an actual circumstance for practice. Multiple functions, rural practice, easy assembly, well shaped appearance and correct anatomical landmarks provides a very good training for practice.Features :
Head Care. Body care. Patient moving. Different lying pose. Bilateral and Unilateral oxygen inhalation. Atomization inhalation therapy. Nasal Feeding. Gastric lavage training. Intravenous Injection. Intramuscular Injection. Hypodermic Injection. Various fistula orifice washing practice. Male Catheterization. Male Bladder Washing. Enema Treatment. Simulator Assembly.Monocot Leaf T.S.
Tooth Hygiene Set
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
francis turbine test setup
DESCRIPTION:
Francis Turbine is a reaction Turbine, which was developed by English born American Engineer Sir J.B. Francis. The water enters the turbine through the outer periphery of the runner in the radial direction and leaves the runner in axial direction and hence it is called a mixed flow turbine. As the water flows to the runner, a part of pressure energy goes on changing into kinetic energy. Thus the water through the runner is under pressure. The runner is completely enclosed in an air tight casing and the casing & runner is always full of water. The present Set-up consists of a runner. The water is fed to the turbine by Means of centrifugal Pump, radially to the runner. The runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. The circular window of the turbine casing is provided with a transparent. The circular window of the turbine casing is provided with a transparent acrylic sheet for observation of flow on to the runner. The runner assembly is supported by thick cast iron pedestal. Load is applied to the turbine with the help of brake arrangement so that the efficiency of the turbine can be calculated. A draught tube is fitted on the outlet of the turbine. The Set-up is complete with guide mechanism. Pressure and vacuum Gauge are fitted at the Inlet and Outlet of the turbine to measure the total supply head on the turbine.UTILITIES REQUIRED:
● Water Supply and Drain.● Electricity 15 kW, 440V Ac, Three Phase
TECHNICAL SPECIFICATIONS:
| MODEL | HM 101 (1.33 HP) | HM 101 (2 HP) | HM 101 (5 HP) |
| Output Power | 1.33 HP / 1 Kw | 2 HP / 1 Kw | 5 HP / 3.75 Kw |
| Discharge | 1000 LPM (Approx.) | 1000 LPM (Approx.) | 2000 LPM (Approx.) |
| Supply Head | 10 m | 10 m | 15 m |
| Rope Brake Dynamometer | Dia 200 mm | Dia 200 mm | Dia 300 mm |
| Sump Tank | Capacity 300 Ltrs. | Capacity 300 Ltrs. | Capacity 600 Ltrs. |
| Water Circulation Centrifugal Pump | Capacity 5 HP, Three Phase | Capacity 5 HP, Three Phase | Capacity 15 HP, Three Phase |
| Speed | 1500 RPM (approx.) | ||
| Runner | Having Curved Vanes | ||
| Discharge Measurement | Pitot Tube with Manometer | ||
| Control Panel | Star/Delta Starter, Mains Indicator, MCB for overload protection | ||
| The whole set-up is well designed and arranged in a good quality painted structure. | |||
Hydraulic Disc Brake Actual Working
Air Conditioning Trainer Window Type
Window air conditioner is becoming now a day’s necessity. The unit demonstrates the application of window air conditioner & evaluation of its performance. It consists of a small room to which a small air conditioner is connected the room is provided with a transparent front cover with a heater inside to simulate heat load in the room. Various measurements are provided so that performance of system that is COP of system, actual & theoretical cooling capacity of system & power consumption of unit with different load conditions.
SPECIFICATIONS:
1.Compressor – Hermetically sealed, Kirloskar make, having the capacity of 1/10 ton of refrigeration using R-12 refrigerant to keep room temperature between 20 to 30 c. 2.Condenser – Finned tube type, with forced air flow over the tubes, 3.Capillary tube of matched length as expansion device. 4.Evaporator – Finned tube type with forced air flow, 5.Room – 0.6 X 0.7 X 0.7 m. height, provided with transparent front wall. A heater with input control is provided inside the room. Which simulates different load conditions. 6.Measurements and Controls a) H.P. / L.P. Pressure gauges b) Digital temperature indicator to measure the temperatures at various points. c) Energy meters to measure input to compressor & heater. d) High and low pressure cutout. e) Thermostat to put off the compressor at set room temperature. f) Necessary switch for electrical components.SERVICES REQUIRED:
1.Floor area of 2m X 1 m. 2.230V, 15AC stabilized supply with earthing connectionXTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
DC Network Analyzer
Specification
• Here we provide the bi-polar Transmission Line. • Simulated long, medium & short distribution lines selectable by patching in various length of DC Transmission line • Two no of bi-polar DC generator sources with ON/OFF control and voltage regulator potentiometer. - Two wire or Three wire Transmission Line operated in +12V DC - Each DC generator are independently control by potentiometer. • 2 digital voltmeters and ammeters provided in the input side and 2 digital volt meters and ammeters are provided in the output side • of transmission line to read the input & output parameters of transmission line. • One no of microcontroller based measuring system provide to read the input and output parameters. • 4 nos of digital ammeters provided to read the load current • 4 nos of resistive load and 4 nos of lamp loads are provided to load the transmission line.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Heart With Artery Blockage Models
HVDC Transmission Line Simulator
The HVDC Transmission due to its advantages, like long distance transmission, interconnect different power systems (like 50Hz and 60Hz), more energy transmits than AC, less losses, make it essential for the students to study & understand the operation of HVDC. Vi Micro have introduced a trainer for this purpose “HVDC Transmission Line Simulator”
HVDC Transmission Line System consists of
• Generating Station Module • Rectifier Station Module (SCR or IGBT Based) • Simulated HVDC Transmission Line Module • Inverter Station Module • Loading ModuleGenerating Station Module
• It consists of a 3Φ, 415V Variable AC source, 1.5 KVA step up transformer, a Multifunction Meter (To measure various electrical parameters of • Generating side or sending end) & a Miniature Circuit Breaker. • Earth Fault Relay is provided for protection against Earth Fault. • The module is covered with metallic enclosure and sticker represents the prime operation of the module. Safety power plug-sockets are provided.Rectifier Station
• Two no’s of fully controlled SCR based bridge rectifiers provided to convert 3Φ AC to DC for HVDC transmission. • Two 6 Pulse SCR bridges connected in series • Can be configured as 12 Pulse Rectifier • A 3Φ, 1.5KVA transformer with (Y) primary and dual (Δ, Y) secondary are provided to reduce harmonics • The module is covered with metallic enclosure and sticker represents the prime operation of the module.Lathe Tool Dynamometers
This is a strain gauge type two component lathe tool dynamometer designed to measure vertical and horizontal forces on the while orthogonal cutting process. The unit is in two parts one is mechanical sensing unit or tool holder, which can mounted on the top of the Ross slide after removing swivel base and compound slide of a lathe and digital force indicator. With this Dynamometer student can study the change in these forces by varying Speed, Cut and Feed.
FEATURES:
1.Rigid in construction 2.Sensitive transuding and amplifying system for accuracy in force measurement. 3.Compact Digital force indicator. 4.Use of cutting fluid during operation is possible.SCOPE OF SUPPLY:
1.Mechanical sensing unit or Tool Holder with string gauges. With H.S.S. tool of ½ “ size. 2.Control panel housing digital force indicator to measure two forces simuletensiously, balancing potentiometers, connoting cable. 3.Necessary switches, fuses and polycarbonate front plate. Range o to 500 Kg. 4.Centre Height, P.C.D.of clamping bolt size, clamping Bolt size. Three component lathe tool dynometer is also available.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















