XTEMOS ELEMENT
AJAX PRODUCTS TABS
Advanced Nursing Baby
Description
This Advanced Nursing Baby Manikin is specifically designed for professional nursing training. This high quality manikin will provide wide range of exercises possible including both first aid and emergency situations.BASIC NURSING SKILL:-
Movable head, neck, hand and foot Cephalic vein puncture Umbilic vein injection Oronasal intubation nursing Stomach washing, clyster and catheter nursing Ostomy Hand-foot subcutaneous injection Washing, lactation, dressingWave Machine, Metal
CNC Lathe Trainer2
CONTROLLER:
SIEMENS / FANUC Main Spindle Drive : AC Motor with VFC Z and X Drives : Stepper drive with Servo Motor Input to Servo : Optically lsolated Motor Drive : Smart & Intelligent Run Speed Control : Through Controller Interpolation : Linear/Circular /parabolic Cycles Used : G, M, S, T, F, I, K, M, F, Circular interpolation / Canned Threading : Straight / Taper Power Devices : Short Circuit and over Temperature Protected, Single Phase Protection Real Time Toolpath Simulation : ProvidedMACHINE DETAILS:
Center Height : 150mm Swing over Carriage : 125mm Distance between Centre : 825mm Weight : 1100kg Dimension in mm : 2000 x 1200 x 1700 Rapid Travel : 5000mm/min Resolution Z Axis : 1 micron Resolution X Axis : 1 micron (Dia.) Automatic Lubrication : Provided Tool Changer : Automatic – 4 station SPINDLE Spindle Speed : Continuous Variable Spindle power : 3 HP Inside Taper : MT4 Speed Range : 50 to 1800 RPMAXIS TRAVEL:
X Axos : 120mm Z Axis : 800mmResistance Unit
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Parallelogram of Forces Apparatus
CALCIUM CHLORIDE TOWER 250ML
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Flourimeter (Digital)
A digital photofluorometer, you can perform precise analysis of flurophors and quinine.
Designed specifically for life science laboratories, this smart instrument fulfills your requirements of accurate results with the sensitivity you demand.
This fluorometer is a compact system, which occupies very low bench space, while offering convenient and excellent throughput for fluorescence assays.
It is a fluorometer model has been designed and manufactured for laboratories, where routine analysis of fluorophors is a prime requisite.
This system uses 50 W tungsten halogen lamp,
This digital fluorometer greatly enhances productivity of your laboratory, designed with latest technology, use of imported mechanical and electrical parts, imported lamp and other components; it allows you to perform fluorometric determination of quinine more quickly.
| Covers entire visible range: | Excellent detection sensitivity | |
| Compact and efficient: | Bright red seven segment LED display | |
| Occupies low bench space: | Precise analysis of Flurophors & Quinine |
Specifications
| Fluoro Sensitivity: | Full-scale deflection obtained with 1 ppm quinine sulfate in 0.1 N sulphuric acid (primary wavelength 360 nm) | |
| Display: | 3 digits bright red seven segments LED display | |
| Excitation Source: | 12V, 50W Tungsten Halogen Lamp | |
| Sensitivity Range: | Adjustable in 4 ranges | |
| Detector: | Highly sensitive wide range photodiode/cell | |
| Sample Test Tube Size: | 15 mm (D) x 80 mm (H) | |
| Minimum Sample: | 4 ml | |
| Power: | 230 V ± 10%, 50 Hz. AC | |
| Dimension: | 260 x 335 x 160 mm (Approx.) |
Human Ear, Enlarged, 2 Parts
PATHOLOGY INCLINED MONOCULAR MICROSCOPE
PRODUCT DESCRIPTION:
OBSERVATION HEAD: MONOCULAR Inclined at 45° and Rota table 360º with perfectly centered Quadruple BAL Bearing revolving nose piece. OBJECTIVE- 4/5x, 10x, 40/ 45x, 100x (oil). EYE PIECES- 10x WF (one), Huygenian 5x or 15x (Any one)MECHANICAL STAGE: Double plate 130x140 mm Low drive mechanical stage for X & Y movement with Sub stage bright field condenser N.A. 1.25 & iris diaphragm with built in swing out filter holder and up-down movement through rack & pinion. FOCUSING SYSTEM: Separate Coarse & highly sensitive fine movement mechanical graduated to 0.02mm. With locking device. EXTRA LARGE BASE: To support the robust arm, has built in with LED cooled bright Illumination or 6V 20 W HALOGEN LAMP with soft start continuously variable intensity controlled regulator & quick change bulb provision. PACKING: Microscope supplied one Plano concave mirror for use in day light, duster, cover & instruction manual.
Demonstraton Electric Bell
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Autoclave Vertical Sterilizer
Specifications
Made of stainless steel with the inner chamber of a thick pressure gauge. The outer surface has a mirror polish. The lid of this autoclave is thick along with a safety valve, pressure release valve, and drain valve. Spring loaded valve to adjust the pressure. Works on 220V AC. Radial or wing nut type door locking. Digital temperature indicator. Water level indicator.| Dimension | Power | Capacity | |
|---|---|---|---|
| 250x450mm | 2KW | 22litres | |
| 300x500mm | 3KW | 40litres | |
| 350x550mm | 4KW | 50litres | |
| 400x600mm | 5KW | 75litres | |
| 450x600mm | 5KW | 95litres | |
| 550x750mm | 6KW | 187litres |
PP Cryo Box
We bring forth the finest range of PP Cryo Boxes.
Moulded in Polypropylene, the top of the box is attached to the bottom through well designed built-in hinges.
The bottom has built-in spaces to hold vials up to 2 ml. Capacity.
Available in two different sizes, these autoclavable PP Cryo Boxes bear alpha numeric index for easy identification of different vials placed inside.
| Particulars | Pack (Pcs) | |
|---|---|---|
| Cryo Box (P.P) - 81 places for 1 ml or 1.8 ml cryo vails | 4 | |
| Cryo Box (P.P) - 100 places for 1 ml or 1.8 ml cryo vails | 4 |
TMS320VC5416 Based DSP Trainer
This Kit provides new performance enhancing Features such as USB Communications. This is Suitable for applications that require optimized Combination of Power Performance & area. Suitable for the range of Signal processing applications, including speech Compression / decompression Speech recogniation, echo generation and Cancellation.
ON-CHIP FEATURES:
• 160MIPS Performance, can operate upto 160MHz • Advanced multi bus architecture with one program bus, three data buses and four address buses • 40-bit arithmetic logic unit (ALU), including a 40-bit barrel shifter and two independent 40-bit accumulators • 17-bit × 17-bit parallel multiplier coupled toa 40-bit dedicated adder for non pipelined single-cycle multiply/accumulate (MAC) operation. • Compare, select, store unit (CSSU) for the add/compare selection of the Viterbi operator • Exponent encoder to compute the exponent of a 40-bit accumulator value in a single cycle • Two address generators, including eight auxiliary registers and two auxiliary register arithmetic units.ON-BOARD FEATURES:
• 4 Mbit (256Kb x 16) Flash Memory • 4 Meg (256K x 16-Bit) Static RAM for External Program/Data • 8 way DIP switch & LED • ON Board JTAG Emulator (XDS 100 version - 2) • PCM3002 AUDIO CODEC • Expansion connector for GPIO & Peripheral interface • On board USB for serial communicationXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Digital Coating Thickness Meter
Description
Digital Coating Thickness Meter We offer high quality of Digital Coating Thickness Gauge. Statistics (Number of readings, average, Std. deviation, max. ,; min.) are updated with every reading and displayed simultaneously. It helps to decide how many readings are to be taken. Continue taking readings till you start getting reasonably consistent statistics.Ultrasonic Transmitter And Receiver Set
This apparatus consists of a self-contained transmitter and receiver operating in the 40 kHz region. The transmitted wave is modulated at a user controlled variable frequency of about 2 kHz and this is detected by the receiver which amplifies the signal and drives a miniature integral loudspeaker. Both transmitter and receiver are contained in separate plastic enclosures measuring 175 x 100 x 40 mm which contain all the electronics and the 9 V batteries. The receiver has front panel 4mm sockets so that the output can be monitored on an oscilloscope for more quantitative measurements. The system is ideal for demonstrating sound waves above the hearing threshold and reflection properties associated with sonar etc. A special feature is the second transducer on the transmitter which can be switched on when required to produce two coherent sources. By moving the receiver along a line parallel to the two sources interference patterns can be dramatically demonstrated simplifying the Young’s slits experiment or enabling it to be demonstrated using waves other than light. Complete with batteries, full instructions and suggestions for use.
Adult CPR Training Full Body Manikin
Description
These manikins are fabricated using an optimum quality raw material to ensure they resemble the human body nicely. Having all the necessary indicators, these manikins are highly reliable and certainly the best way to polish skills.Features:
Indicates correct/incorrect artificial respiration. Right/wrong position display. Stimulates patient through heart pressure and artificial respiration.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















