XTEMOS ELEMENT
AJAX PRODUCTS TABS
Three Phase Transmission Line Fault Analysis Trainer
Three phase Transmission line fault Simulation Study Module
Specification
• 3 phase power supply from 3 phase generator • To simulate 3 phase balanced system fault and unsymmetrical faults • Fault study with single line and double line in 3 phase system • Faults : - L-G-Fault - L-L-Fault - L-L-G-Fault - Single Conductor open fault - Double Conductor open fault - Fault through impedance • Theoretical calculations and verification with practical results. • The transmission lines are simulated by high frequency Inductance & resistance for short, medium and long line.Thermal Conductivity Of Insulating Powder
The apparatus consists of an insulating powder, which is enclosed in a cavity of two concentric spheres. The inner space of the inner sphere contains the mica heater. Input to the heater can be adjusted by the dimmerstat. The tappings on the surfaces of the inner sphere and outer sphere are used to find out the temperature difference between the spheres. This enables to find out the conductivity of powder.
Specifications:
1.Inner sphere dia. 100mm and outer sphere dia. 200mm. 2.Mica heater two heat the inner sphere surface. 3.Ten thermocouple tappings in the test section. 4.Plaster of Paris / asbestos powder in the test section. 5.Panel comprises of a)Voltmeter and ammeter b)Dimmerstat c)Temperature indicatorServices required:
1.220v stabilized single-phase supply. 2.Floor surface 1m x 0.5m at working height.Human Reproduction Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting with plastic rollers, size 75 x 100 cm. Human embryological development. Human Life cycle (birth). Human reproductive organs, male. Human reproductive organs, female.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Line Ranger
Description
Our expertise enables us to develop a broad range of measuring and survey equipment and instruments such as Line Rangers. Manufactured using high grade metal and alloys, these line rangers can be availed in standard as well as customized sizes and specifications. Used for various testing and measuring activities by our clients, our range can be availed at most descent prices.Orbital Shaking Incubator cum B.O.D
Specification
Orbital shaking incubator cum B.O.D incubator is specifically designed to controlled incubation with orbital shaking arrangement with powerful geared motor for many labotatory procedures such as tissue culture, fermentations studies, enzyme reactions, growth studies etc. The outer chamber is made up of M.S sheet duly powder coated & inner chamber is made of thick S.S. sheet. The gap between wall is fitted with high grade glass wool to avoid thermal loss. The plexi glass window provided to inspect the specimen without disturbing the inner temp. The incubator is illuminated with one door operated or panel operated flurescent tube. The unit has a temp. Range from 5°C to 60°C. The temperature is controlled by Dual Display Microprocessor PID Temperature Indicator cum Controller with a accurancy of + 0.5°C. Air circulation fan is provided to maintain stability throughout. The speed of shaker is variable from 30 RPM to 250 RPM. The tray of the shaker is also made of S.S sheet with lotus type clamps to hold flasks. The unit is fitted with Digital RPM meter, 999 min digital timer.Optional Accessories
Timer 0-24 Hours. Automatic voltage stabilizer 3KVA (Most rec.).Size
16 Flasks of 500ml. 25 Flasks of 250ml. 36 Flasks of 100ml.Cryo Coders
We are a leading Exporter & Trader of Cryo Coders.
The Cryo Coders offered by us are available in different colors can easily fit into the cap of cryo vials for color identification of different samples.
Avail the Cryo Coders from us at leading market prices.
Material : Polystyrene
Particulars | Pack (Pcs) | |
---|---|---|
Cryo Coders | 100 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Optical Bench, Aluminium
Description
Bench has two steel rods, one of which is graduated in mm with heavy metal and supports with leveling screws with four metal slides which slide smoothly on the bench. Two of the slides have transverse motion arrangement. Complete with two lens holders and two object needles. Graduated to 1 m Graduated to 1.5 mStereo Zoom Microscope
Specifications
Magnification | : | 20x & 40x or 30x and 60x | |
Eyepiece Lens | : | Wide Field 10x or 15x Paired Eyepiece | |
Objective | : | 2x and 4x (Turret Type Revolving) | |
Focusing | : | Vertical movement with rack & pinion, Tension control knob & stroke 50 mm | |
Inclination | : | 45° | |
Tube Rotation | : | 360° Rotatable, Removable |
Accessories
Rubber Eye Guard. LED Light Illuminator or Flurescent Ring Illuminator.Slip Creep Measurement Apparatus
The apparatus consists of a variable speed D.C. Motor, Driving pulley and Driven pulley of equal diameter. The pulleys are mounted on input shaft (Motor shaft) and output shaft. The driven pulley can slide on the base with bearing block to change initial tension in belt. Brake drum is mounted on output shaft helps to measure power output. The motor speed is varied by dimmerstat. A two channel RPM Indicator is provided to measure speeds of driven and driving pullies respectively.
Specifications:
1.D.C. Motor – 1 HP, 1500 RPM, variable speed. 2.Driving & Driven puilies of equal diameters. 3.Brake drum along with spring balance. 4.Fiat Belt of fixed length of following materials – (i)Fabric Belt (ii)Canvas Belt. (iii)Rubber Belt. 5.Belt tightening arrangement. 6.Speed Controller unit. 7.Two Channel digital RPM Indicator. 8.Stroboscope.Experimentation –
1. To measure co-efficient of friction between pulley material and different belt materials. 2. To measure power transmitted with varied belt tensions and plotting graph of (T1 – T2).Tension Characteristics. 3. To measure percentage slip at fixed belt tension by varying load on brake drum and plot graph of (T1-T2) Vs.percentage slip.i.e. Slip Characteristics. Finding a creep zone from graph. 4. To measure belt slip speed and observe the limiting value float at constant speed when the slip just starts.Service Required:
1.230 V.A.C. stabilized power supply 2.Space -. 1.5m x 1.5 m.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Dissecting Boards
Refrigeration Test Rig
Features
• 5 Nos of thermocouples are provided to measure the temperature at different points. • One multi channel temperature indicator is provided to display the temperature • One capillary tube and one thermo expansion valve is provided to check the performance separately. • Compressor supplies refrigerant through evaporator to find out cooling effect • 4 Nos. of Pressure Gauges are provided to measure the pressure at various point • One Energy meter is proivded to measure the overall power consumption • One voltmeter is provided to display the voltage. • One ammeter is provided to display the current.Specification
• Compressor :Hermatic • Capacity : 1/4 Ton • Supply : 230 V AC / 50 Hz • Condensor : 12 Coil • Evaporator : 15 Liter Capacity • Refrigerant : R134AInternally Expanding Mechanical Drum Brake System
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Induction Coil, Ruhmkorff
Description
Coils are wound with highly insulated copper wire impregnated with paraffin wax; input 6-8 V dc through two 4 mm socket terminals, with an adjustable trembler system. The spark suppression capacitor is housed in the base. A pair of pointer electrodes with insulated handles for adjustment of the spark gap is provided. Spark length 10 mm Spark length 25 mm Spark length 50 mm Spark length 75 mm Spark length 100 mmBalance Spring
Arteries With Heart Models
We offer arteries with heart models that are widely used to explain the function of artery and hearts to the students.
Our models provide the best way of understanding the functions of these parts, which are explained with the help of different colour combination.
These models are mostly used in school and colleges so that students are able to understand the function of these parts in the effective manner.
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT