XTEMOS ELEMENT
AJAX PRODUCTS TABS
Pulse Code Modulation/Demodulation
FEATURES:
• In-built sine wave generator • Test points to study different waveforms • In-built DC Power supplyTechnical Specifications:
• Sine wave Generator : Frequency : 1 KHz, Amplitude : 0 to 3Vpp • DC Voltage : -1.5 V to +1.5V • Clock Generator : Crystal based, 4.096MHz • Data rate : 64 kbps (for 8 KHz sampling rate)128kbps (for 16 KHz sampling rate) • ADC and DAC bits : 8 • Demodulator filter type : Butterworth low pass filter • Filter type : 6th • Filter cut-off frequency : 3.4 KHz • Mic Pre-amplifier : Transistor based • Compandingrange : -80dBm to +20dbm • Switched faults : 4 • Test points : 35 • Fuse : 30V, 100mV • DC Supply : ±5V, ±12V • System Bandwidth : 3.4 KHzWater Cooler Trainer
The apparatus consists of a storage water tank, embraced by evaporator coil of the cooling unit, cooling cycle comprises of a hermetically sealed compressor, air-cooled condenser, a capillary tube as expansion device and an evaporator cell. The stainless steel water tank is provided with insulation on air Sides and a door are provided at the top. Cold water can be taken out from a top provided and inlet water supply is controlled by a bail-operated top. Various measurements provided enable students to determine the theoretical and actual COP, power consumption, actual cooling capacity refrigerant flow and compressor volumetric efficiency of compressor.
SPECIFICATIONS:
Cooling Cycle a) Compressor Hermetically sealed type, having the capacity of 1/3 ton of refrigeration using R-12 refrigerant. b) Finned tube type air colled condenser with forced air flow. c) Filter cum drier for refrigerant. d) Capacity expansion device. e) Evaporator coil embraced on stainless steel water tank, Provided with glass wool Insulation. 2.Water drain tap and float operated inlet water tap are provided for water tank with insulated lift door at top. 3.Measurement a) Pressure gauges for evaporating and condensing pressure. b) Thermometers to measure refrigerant temperatures at inlet and out let of condenser and evaporator. c) Dial type thermometer for water temperature. d) Rotameter to measure liquid refrigerant flow. e) Energymeter to measure compressor Input. 4.Safely & Controls – a) Thermostat to put off compressor at set water temperature. b) Pressostat to put off compressor if high or low pressure Goes out of set limit. c) Over load protector for compressor, A technical manual will be supplied along – with the unit. Also, the unit is provided with an attractive and anti corrosion powder costing.SERVICES REQUIRED:
1.Floor space of 1.5 m. X 1.5 m. 2.Water supply of 5 lit/min, 3.230 V, 15A AC stabilized supply with earthing connectionHuman Ear, Enlarged, 2 Parts
Resonance Apparatus, Simple Form
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Tuning Forks Set, Even Frequency
Vacuum Delivery Model
Description
The model basing on the mechanism of normal labor shows the cardinal movements of engagement. Descent-flection-internal rotation of the head-extension-retitution-external rotation of the head-internal rotation of the shoulders at accouchement. Suitable for teaching the mechanism of normal labor in medical colleges and nursing schools.Formation Of Rocks
Electromagnet
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Electronic Balance
Slip Creep Measurement Apparatus
The apparatus consists of a variable speed D.C. Motor, Driving pulley and Driven pulley of equal diameter. The pulleys are mounted on input shaft (Motor shaft) and output shaft. The driven pulley can slide on the base with bearing block to change initial tension in belt. Brake drum is mounted on output shaft helps to measure power output. The motor speed is varied by dimmerstat. A two channel RPM Indicator is provided to measure speeds of driven and driving pullies respectively.
Specifications:
1.D.C. Motor – 1 HP, 1500 RPM, variable speed. 2.Driving & Driven puilies of equal diameters. 3.Brake drum along with spring balance. 4.Fiat Belt of fixed length of following materials – (i)Fabric Belt (ii)Canvas Belt. (iii)Rubber Belt. 5.Belt tightening arrangement. 6.Speed Controller unit. 7.Two Channel digital RPM Indicator. 8.Stroboscope.Experimentation –
1. To measure co-efficient of friction between pulley material and different belt materials. 2. To measure power transmitted with varied belt tensions and plotting graph of (T1 – T2).Tension Characteristics. 3. To measure percentage slip at fixed belt tension by varying load on brake drum and plot graph of (T1-T2) Vs.percentage slip.i.e. Slip Characteristics. Finding a creep zone from graph. 4. To measure belt slip speed and observe the limiting value float at constant speed when the slip just starts.Service Required:
1.230 V.A.C. stabilized power supply 2.Space -. 1.5m x 1.5 m.Hydraulic Drum Brake Actual Working Four Drum
Curved Member Apparatus
Apparatus consists of a steel bar which is used to make the different curved members Viz. circle, semicircle with straight arm, a quadrant of a circle and quadrant of a circle with straight arm. The bottom ends of the members are fixed to the base. Under the application of load at free end, its horizontal and vertical deflection can be measured with the help of dial gauges. A dial gauge with 25mm travel (with a magnetic base) is supplied with the apparatus. Apparatus to be supplied should be complete with a supporting stand and a set of weights.
Experimental Capabilities: Apparatus is supplied complete with a supporting stand and a set of weights.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

CNC Lathe Trainer With Servo Drives
CONTROLLER:
(1) Type of control system: PLC based system (2) Main Spindle Drive : AC Motor with VFD (3) Z and X Drives : Stepper drive with RAMP function (4) Input to Stepper Motor : Optically Isolated (5) Motor Drive :TTL Compatible (6) Run Speed Control : Computer controlled through software (7) Interpolation : Liner / Circular / Parabolic (8) Cycles Used :G,M,S,T,F,I,K,M,F (9) Cycles : Circular Interpolation / Canned (10) Threading : Straight / Taper (11) Power Devices : Short Circuits and over Temperature Protected (12) Real Time Tool Path Simulation : ProvidedMACHINE DETAILS:
(1) Center height : 100mm (2) Swing over Carriage : 80mm (3) Distance between Centre : 250mm (4) Longitudinal Travel : 250mm (5) Weight : 350 kg (6) Dimension in mm : 1100 x 750 x 1700 (7) Rapid Travel : 500mm/min (8) Resolution X & Z Axis : 10micron (9) Dt. Motor Power : 40V – 4A (10) Lubrication : ManualSPINDLE:
(1) Spindle Speed : Continuous Variable (2) Spindle Power : 2 HP (3) Inside Taper : MT3 (4) Speed Range : 50 to 3000RPMStefan Boltzmans Apparatus
The Stefan Boltzmann constant is an important constant in heat transfer. The apparatus determines Stefan Boltzmann constant. The apparatus consists of a hemisphere surrounded by hot water. Hot water is obtained from a water-heating tank. When the blackened disc is inserted at the center of hemisphere, heat is transferred into the disc from hemisphere by radiation and its temperature begins to rise, and from temperature raise rate. (It is measured at the intervals of 5 sec.) Stefan Boltzmann constant is determined.
SPECIFICATIONS:
Water heating tank provided with electric immersion heater. Hemisphere made of copper sheet, 200mm. dia. Surrounded water jacket of 250mm. Dia. Test disc made of copper 20mm. dia. provided with thermocouple at the center. Multichannel digital temperature indicator 0-200 C with 0.1C least counts to measure the temperature of hemisphere and disc. Audible buzzer with timer to ring at every 5 seconds. A technical manual accompanies the unit.SERVICES REQUIRED:
1.Bench area of about 1m. x 05m. at working height. 2.230v, 15A, AC, electric supply with earthing connectionLaser Distancing Meter
Description
Laser Distancing Meter The professional Laser Distance Meter is designed to give special users a high accuracy, one person distance measuring and estimating tool measure remote and difficult reaching places. The compact and handy base model was specifically designed for indoor applications. Shortcut keys for addition, subtraction, Pythagoras, area and volume calculation make measuring fast and very reliable. The last 20 measurements are also stored. Simple to Operate: Due to the shortcut keys addition and subtraction, as well as surface and volume calculations could be easier. Features : Area, Volume Calculations Indirect measurement using Pythagoras Addition/ Subtraction Continuous Measurement Min/ Max. Distance Tracking Display illumination and multi-line display Buzzer indication Multifunctional end pieces.Brush, Test Tube
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Protozoa
Description
All Charts are made on PVC rexine , hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall. Size 75×100 cm. Amoeba structure & locomotion Plasmodium (Malarial Parasite), stages of development Paramecium structure Paramecium Reproduction Euglena structure & Life History Entomoeba Histolytica – structure & L.H.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT