XTEMOS ELEMENT
AJAX PRODUCTS TABS
Utility Tray
We excel in providing high quality Utility Tray to our valuable clients.
Our range of Utility Tray is well appreciated in the market for its high quality and durability.
this Polypropylene Tray can be utilized for wide range of purposes ranging from drying glassware to sterilizing and for storing any laboratory apparatus.
Material : Polypropylene
| Particulars | Pack (Pcs) | |
|---|---|---|
| Utility Tray 375 x 350 x 130 mm | 6 |
Electric Motor, Demonstration
Xilinx Spartan 3E FPGA Trainer Kit
Specification
• XC3S250E - 4PQ208C / XC3S500E-4PQ208C • 16 Nos. of digital input using slide switches with LED indication • 16Nos. Of digital outputs using discrete LEDs • 16 x 2 LCD is provided for display the text message. • One Reset Switch • One switch is provided for giving manual clock • FPGA configuration through - JTAG Port - On board Flash Prom XCF02S • Total 158 I/O pins : 124 pins used for integrating peripherals like LED, Switches etc., balance pins available to user in 20 pin • header (3.3V compatible) • 1No of 26pin header to interface VLIM cards like Traffic Light Controller (5V compatible) • On board programmable PLL oscillator from 1 MHz to 100 MHz using jumpers • 4 Nos of 7 segment LED display • One relay and Buzzer provided. • Stepper & DC motor Driver provided. • 4 * 4 matrix key provided • Housed in a sleek plastic cabinet with built in SMPS 5V/2A. • Compatible with Xilinx ISE Design Suite WebPACK Software. • On board USB to JTAG is available for configure FPGA (Supports only with Vi JTAG 5.0 Software)Meter Scale, Hardwood
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Kidney Section, Nephrons , Blood Vessels And Renal Corpuscle
Description
Set of three models on one board. Kidney section, 3 times full size. Nephrons and blood vessels 120 times full size showing a section through renal cortex and medulla. Malpighian corpuscle of kidney,700 times enlarged showing an opened Malpighian corpuscle with glamerules and Bowman’s capsule. On base with key card.PAM-PPM-PWM Modulation and Demodulation Trainer
PAM- PPM- PWM is the basic pulse modulation techniques. This trainer provides complete setup to the students for performing Experiments on these techniques. They can study Sampling, Pulse Modulation &Signal reconstruction process. Separate circuits are provided for each Techniques.
FEATURES:
• PAM- PPM- PWM Modulation and Demodulation Techniques,using Natural and Flat - top Sampling. • Natural Sample, Sample and Hold and Flat-top outputs. • Selectable 2 different sampling pulse frequencies on board. • On board Sine wave generators. • Voice communication using dynamic microphone and speaker • On board Filters and Amplifier • Functional blocks indicated on board schematic • Input- Output and Test points provided on board. • Built in DC Power Supply • Fully documented operating ManualTECHNICAL SPECIFICATION:
• Crystal Frequency : 6.14MHz • Sampling Frequency : 16 KHz, 32 KHz • Sine wave Generator : 1 KHz &500Hz, Amplitude (0-5)V, Tolerance +5% • Low Pass Filter : 4 Order BW Filter • Cut off frequency : 3.4 KHz • Voice Communication : Voice Link using dynamic mic& speaker • AC Amplifier : With Adjustable Gain control • Microphone type : Dynamic, 600 Ohm. • Audio Pre-amplifier : Op-amp based • Power amplifier : 1W Mono • Interconnections : BS2 Connector. • Power : 230V, 50HzResistance Units, Interlocking
Whirling Of Shaft Apparatus
The unit consists of a main spindle driven by a variable speed motor. Three different governor assemblies can be mounted over the spindle. A with pointer measures the lift of the governor. Students can calculate characteristics of governor at and compare their performance viz. Sensitiveness, stability, governor effort etc.
SPECIFICATIONS OF WHIRLING OF SHAFT APPARATUS:
1.Governor assemblies – Hartnell, porter & propel governor assembly one each with rotating weights. 2.Variable speed FHP D.C. motor to drive the main spindle. 3.Sliding weights for porter & proell governor. 4.Scale & a pointer to measure governor lift. 5.Spring & Spring compression adjustment arrangement. 6.A technical manual accompanies the unit.SERVICES REQUIRE FOR WHIRLING OF SHAFT APPARATUS:
1.230V, 5A, AC supply connection. 2.Bench area of 0. 75 x 1m. at working height.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Frequency Shift Keying Modulation And Demodulation
This Instrument is design to demonstrate the method to transmit signals via. Electromagnetic transmission and to study the Frequency Shift Keying Modulation and Demodulation. Whole instrument is placed in plastic moulded box and 2 mm banana plug leads are provided for modulation and demodulation connections.
Calorimeter copper
Refrigeration Trainer Electrolux Type
This type of refrigeration is usually used for domestic purposes only as it is complex in the construction and working. This type of refrigerator was developed in 1925 by Munters and Battzervan when they were studying at Royal Institute of Technology At Stockholm for their undergraduate course. This type of refrigerator was known as three fluid refrigeration system. The elimination of aqua pump from the absorption system with the complete absence of moving parts and work input. The main purpose of removing the pump was to make the machine noiseless. It uses refrigerant as a solvent s and an inlet gas for inlet of the system. The inert gas is continued to the lower side of system only by its system. It is possible to maintain the uniform pressure throughout the system and after sometime permitting the refrigerant to evaporator at low temperature corresponding to its partial pressure. In the high pressure side system (generator and condenser), there exists only the refrigerant which is subjected to total pressure of the system so that it is condensed by using normal cooling water as air as it is done in other system.
The strong aqua ammonia solution is heated in generator by the application of external heat source. The water vapor carried with ammonia vapor is removed in separate form as shown in figure. Then the dry ammonia vapor is passed into the condenser and it is condensed by using external cooling source. The liquid ammonia flows under gravity in the evaporator and it evaporates. The mixture of hydrogen and ammonia vapor is passed into the absorber and the weak solution from aqua ammonia from the separator is allowed to follow into the absorber, through tray this weak aqua ammonia solution comes into contact with hydrogen separated. This strong solution is further passed to the generator and it completes the cycle.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Leaf Anatomy
Charle’s Law Kit
Small Dental Care Model (32 Teeth) PVC
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Single Phase Cyclo Converter
Specification
• Consists of firing circuit, SCR power circuit and load. • Line synchronized IC based linear firing circuit. • Line synchronization achieved by step - down transformer. • Four nos. firing pulse with pulse transformer isolation to trigger four SCR. • One no. potentiometer used to vary the firing angle (180° - 0°). • Carrier logic implemented with carrier frequency of 4KHz. • One no. toggle switch with debounceogic for pulse ON/OFF. • EPROM Based firing pulse frequency variation. • Two nos. toggle switch to select different frequency (Hz, 50/2Hz, 50/3Hz, 50/4Hz). • Power circuit consists of Four nos. SCR with fuse protection. • Anode, Cathode, Gate terminals are terminated in the front panel for user connection. • 24V AC, 1Amp Provided for power circuit input with ON/OFF switch. • One no. fixed R, load provided Center tapped inductor for power circuit. • 230V, 50Hz AC input with ON/OFF rocker switch, fuse for over load.Laboratory Stirrers
We offer comprehensive range of Laboratory Stirrers for our esteemed clients.
Made of polypropylene, these Laboratory Stirrers are very useful for stirring different solutions in the laboratory.
Our range of Laboratory Stirrers proves to be tough and long lasting.
Our buyers can avail these Laboratory Stirrers at highly affordable price range.
| Particulars | Pack (Pcs) | |
|---|---|---|
| Stirrer Ø-10 mm x h-250 mm | 12 | |
| Stirrer Ø-6 mm x h-150 mm | 12 | |
| Stirrer Ø-7 mm x h-200 mm | 12 | |
| Stirrer Ø-7 mm x h-250 mm | 12 | |
| Stirrer Ø-7 mm x h-300 mm | 12 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















