XTEMOS ELEMENT
AJAX PRODUCTS TABS
Band & Block Brake
Aids Virus
Description
HIV virus model is enlarged millions of times, shows the outer lipid membrane with protein structures and the internal nucleus which contains the viral hereditary matter [RNA]. The nucleus is removable and condoms can be put underneath to provide a message regarding measures to be taken for protecting against HIV infections. Supplied without condoms on stand with key card.Resistance Substitution Board
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Coriollis Component Of Acceleration
This set up is designed to study coriollis component of Acceleration of a slider crank Mechanism. The apparatus uses hydraulic analogy to represent the rotating slider. It consists of a rotating block with two arms in opposite direction. These tubes can be rotated at various speeds by using a swinging field motor, which also acts as a dynamometer to measure torque applied to rotating tubes. A Perspex window on top cover helps to visualize the process. Rotameter is used to measure water flow rate through tubes. Water is circulated by small monoblaock pump.
Specifications:
1.Main Tank with fiberglass lining. 2.Rotating Arms 9/6 mm dia, 300 mm long. 3.Motor – Swinging field, D.C., 0.5 HP. 4.Rotameter 5.Monoblock Pump 6.Control Panel comprising of – (i) Speed Control Unit. (ii) Speed Indicator. (iii) Necessary switches. 7.Rigid support frame.Range of Experiment:
Coriollis Component of Acceleration can be determined at various speeds of rotation and water flow rates.Service Required:
1.A.C. Single Phase .230 V. stabilized supply. 2.Floor Space -1.5 m X 1.5 m.Buchner Funnel
Description
Adarsh is engaged in exporting different types of Porcelain Funnels. We are the foremost Exporter, and Supplier of Buchner Funnel (with Thin as well as Thick Stem) and Hirsch Funnel. All the varieties of our Porcelain Funnels are praised for their matchless quality and reasonable pricing.Diameter Sizes
1. Dia 2" 2. Dia 2.5" 3. Dia 3" 4. Dia 4" 5. Dia 5" 6. Dia 6" 7. Dia 8" 8. Dia 10"XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Separating Throttling Calorimeter
AIM
To find out dryness fraction of steam by combined separating and throttling calorimeter.
PRODUCT DETAILS
The steam passing out from separating calorimeter may still contain some water vapour , in it . in other words it may not be absolutely dry . again , in a throttling calorimeter steam after passing through the throttle valve must be superheated or at least dry saturated . this limits the extent of dryness fraction that can be reliably measured , depend up on the pressure of steam in the main steam pipe . if a sample of steam, which may be still wet after passing through the throttle valve i.e it will not be superheated . thus under this condition the throttling calorimeter fails to enable us in determining the value of dryness fraction of steam . to overcome this difficulties we make use of separating and throttling calorimeter . first the steam is passed through separating calorimeter where itlosses most of it’s moisture and becomes comparatively drier, it is than passed through the throttling calorimeter where super heating takes place with out changr of total heat . the temperature and pressure of steam after throttling are measured by using a thermometer and manometer respectively.DESCRIPTION
The set up consist of a separating and throttling calorimeter . a steam generator is provided at the base of the apparatus . a thermostat knob is provided at the front of apparatus to control the temperature inside the steam generator . steam from steam generator is passed from separating calorimeter where most of the water partical get separated from steam and then passed to throttling calorimeter where steam get superheated . after that superheated steam passed through heat exchanger to condense the steam.SAPARATING CALORIMETER
It consist of two concentric chamber , the inner chamber ,and the outer chamber . which communicates with each other through an opening at the top. As the steam discharge through the metal baskets ,which has a large number of holes , the water partical due to there heavier momentum get separated from the steam and collected in the chamber. The comparatively dry steam in the inner chamber moves up and than down aging through the annular space between the two chambers and enters the throttling calorimeter .THROTTLING CALORIMETER
It consist a narrow throat . pressure and temperature are measured by manometer and thermometer . the steam after throttling process passed through the heat exchanger and condensate is collected .UTILITIES REQURIED
1.WATER SUPPLY 3 lit/min (approx) 2.Drain 3.Electric supply : 1phase , 220 V A.C , 2Amp. 4.Steam table for calculation 5.Space required : 1.0 m X 1.0 mTheodolite
Description
We bring forth for our customers watts theodolites which are scientific instruments extensively employed in surveying and engineering work. These are mainly used for measuring angular values in a traverse or network between survey marks. Watts theodolites can also determine a line of sight along a level plane by combining a spirit level and a telescope. Our range of products is subject to customization to meet the needs of our clients, and can be availed reasonable rates.Watts theodolites is mainly used for :
• Surveying and engineering work • Measuring angular values in a traverse or network • Determination of a line of sight along a level planeXTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Leak Test Apparatus (S.S BODY)
Ideal instrument to check blister Packs, Strip for Leak Test.
The old method of separate desiccator and the huge vacuum pump is replaced with the new Leak Test Apparatus in GMP Stainless Steel Body with phenomenal compactness.
The instrument is equipped with Diaphragm type vacuum pump gives the higher level of vacuum in shortest possible time.
Die pressed polycarbonate vacuum desiccator sustains vacuum for a long time.
A vacuum gauge is provided to indicate vacuum level which is connected to isolation valve to disconnect the source.
Thus avoiding the need of continues running of the vacuum pump.
| Body: | Stainless steel. 304 | |
| Desiccator: | SPolycarbonate, 8” Desicator Provided with Digital Timer | |
| Timer: | S3999 sec. Digital | |
| Vacuum Level: | S 22" Hg | |
| Current: | S 5A | |
| Voltage: | S 230 |
Brush, Erlemneyer (Conical)/ Round Bottom/ Flat Bottom Flask
Bio-Agent Cage Acrylic
5KVA IGBT Based Converter Inverter System
DC Motor Specification
• Power : 3HP • Armature voltage : 220V DC • Field voltage : 220V DC • Speed : 1500 RPM • Make : Benn • Double side shaft extensionSlip Ring Motor
• Type : 3phase slip ring induction motor. • Power : 2KW • Stator voltage : Three phase 415V AC, 4A • Rotor voltage : Three phase 210V AC, 6A • Speed : 1410 RPM • Make : BenndsPIC 30F4011 based PWM Controller
• Microchips’ dsPIC30F4011 16 bit digital signal controller operating at 20MIPS • On chip 48K Bytes flash program memory • On chip 1K Bytes data EEPROM • On chip 2K Bytes RAM • Four Compare/PWM output • Six PWM output for Motor control • One 3 channel Quadrature Encoder interface circuit/4 capture input • 9 Channels 10 bit ADC of 500Ksps conversion tune. • One RS232 Compatible serial port Opto isolated & terminated at 9 pin D male connector • 6 PWM outputs and two capture inputs and two compare outputs are terminated at 34pin FRC connector. • 4 Channels of DAC output & 5 channels of ADC inputs are terminated at 26 pin FRC connector • 16 x 2 alphanumeric LCD displayXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Direct Vision Spectroscope
Needle Steel Handle
Emissivity Measurement Apparatus
The apparatus consists of a test plate and a comparator. A black plate is used as a comparator for test plate. When all the physical, dimensions and the temperatures are equal, heat losses from both plates will also be the same, except radiation losses. Hence the input difference will be due to difference in emissive. Both the plates are kept in a panel enclose with perplex front and are given inputs through separate dimmerstats so that temperatures of both can be kept equal. Thus emissivity can determine over a wide range of temperatures.
SPECIFICATIONS:
1.Test plate and Black plates — 160mm. Dia. Aluminum plates, mounted in Panel with mica heater inside. 2.Instrumental panel consisting of- a)Voltmeter and ammeter for input measurement to both heaters through a selector switch. b)Separate dimmers for both the plates. c)Multichannel digital temperature indicator. A technical manual accompanies the unit.SERVICES REQUIRED:
1.Space area of 1.5m x 1 m. at working height. 2.230v, 15A, AC supply with earthing connectionBURETTE STAND
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















