Solar System Model
TMS320VC5416 Based DSP Trainer
This Kit provides new performance enhancing Features such as USB Communications. This is Suitable for applications that require optimized Combination of Power Performance & area. Suitable for the range of Signal processing applications, including speech Compression / decompression Speech recogniation, echo generation and Cancellation.
ON-CHIP FEATURES:
• 160MIPS Performance, can operate upto 160MHz • Advanced multi bus architecture with one program bus, three data buses and four address buses • 40-bit arithmetic logic unit (ALU), including a 40-bit barrel shifter and two independent 40-bit accumulators • 17-bit × 17-bit parallel multiplier coupled toa 40-bit dedicated adder for non pipelined single-cycle multiply/accumulate (MAC) operation. • Compare, select, store unit (CSSU) for the add/compare selection of the Viterbi operator • Exponent encoder to compute the exponent of a 40-bit accumulator value in a single cycle • Two address generators, including eight auxiliary registers and two auxiliary register arithmetic units.ON-BOARD FEATURES:
• 4 Mbit (256Kb x 16) Flash Memory • 4 Meg (256K x 16-Bit) Static RAM for External Program/Data • 8 way DIP switch & LED • ON Board JTAG Emulator (XDS 100 version - 2) • PCM3002 AUDIO CODEC • Expansion connector for GPIO & Peripheral interface • On board USB for serial communicationXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Trapezoidal Prism, Acrylic
Airway Intubation Model
Description
The Difficult Airway Management Simulator offers a realistic airway management training with 24 various difficulty levels including 3 different mouth openings, 2 neck flexibility options, 2 positions for the vocal codes and an inflatable tongue.Training Skills:
Airway opening techniques (head tilt, jaw thrust) Bag-Valve-Mask ventilation Pre intubation airway assessment "Sniffing position" Pressurization of external larynx to improve the laryngeal view Intraoral/intranasal intubation Use of oropharyngeal airway (OPA) Use of nasopharyngeal airway (NPA) Use of laryngeal mask airway Use of video laryngeal scope Use of tracheal intubation scope Confirmation of successful ventilation by thoracic and abdominal movement Feedbacks on incorrect procedures including esophagus intubation and unilateral intubation Securing the tube in place with tapes or Thomas endotracheal tube holderTraining Model Includes:
1 manikin 3 upper incisions 1 lubricant 1 50ml syringe Size: 27.6 x 15.4 x 9.9 inRecommended Equipment:
Macintosh laryngoscope: blade size 3, 4 Tracheal tube: internal diameter 7.0-7.5mm Laryngeal mask Air-Q: size 3.5 LMA supreme: size 4 I-gel: size 4Micro Tip Box
The Micro Tip Box offered by us unique boxes are moulded in polypropylene and are therefore autoclavable.
The box itself is clear providing inside to hold the tips.
The tip holding spaces are uniformly placed to facilitate the use of multi channel pipettes.
The cover is joined to the base through ball catcher hinges and provides excellent protection to the tips.
| Particulars | Pack (Pcs) | |
|---|---|---|
| Micro Tip Box For 96 Micro Tips of 2-10μl | 6 | |
| Micro Tip Box For 96 Micro Tips of 2-200μl | 6 | |
| Micro Tip Box For 96 Micro Tips of 200-1000μl | 6 |
Potentiometer
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Linear Expansion Apparatus
Consisting of a metal rod, 500mm in length and 4.5mm diameter, enclosed in a well lagged, nickle plated brass tube with three tubules for steam, inlet, outlet and thermometer.
The metal rod to be studied is supported in the steam jacket by detachable conical cups situated at each end of the tube.
The apparatus is carried on a heavy gauge channel base at one end of which is an adjusting screw.
At the opposite end is a micrometer screw reading to 0.01mm for measuring the expansion.
Supplied complete with copper, brass & iron rods but without thermometer.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
3 Axis Robotic Trainer
For beginners, this Trainer is very useful to learn the concept and working of a Robo. For experienced people, this helps to make new ideas. This is used to study the ROBO characteristics of arm movement. Each axis has one AC servo motor. Gripper has one miniature cylinder to pick and place the object. Software controls the ROBO arm and measures the motor axis and arm axis. Simplicity of this kit makes maintenance easier and friendly to user. This kit is very flexible to operate and easy to move. Windows based user friendly software to control the arm through microcontroller having the flexible features such as
Features
• Easy to learn • New design • Easy for maintenance • Drive by AC servo motor • Easy to programSpecification
• Arm : Jointed Arm • Axis : 3 • Motor : AC servo Motor • Gripper : Pneumatic • Drive : AC servo Motor Drive • Controller : MicrocontrollerBase
• Angle of movement : 300º • Gear Type : Spur Gear • Position Detector : Limit SwitchIntermediate ARM
• Angle of movement : 90º • Gear Type : Spur Gear, Worm Gear • Position Detector : Limit SwitchVertical ARM
• Angle of movement : 90º • Gear Type : Spur Gear • Position Detector : Limit SwitchElectric Motor St. Louis
Description
The motor consists of a two pole armature mounted between the ends of two bar magnets. The armature has a two section commutator and a pair of slip-rings on its shaft and is so constructed that the wire cannot slip off the iron core. The upper bearing and brushes for the commutator are mounted on a strong upright. Separate brushes are provided for the commutator and for slip rings and each are connected to a terminal. The magnets are held in position by thumb screws.Refrigeration Test Rig
Features
• 5 Nos of thermocouples are provided to measure the temperature at different points. • One multi channel temperature indicator is provided to display the temperature • One capillary tube and one thermo expansion valve is provided to check the performance separately. • Compressor supplies refrigerant through evaporator to find out cooling effect • 4 Nos. of Pressure Gauges are provided to measure the pressure at various point • One Energy meter is proivded to measure the overall power consumption • One voltmeter is provided to display the voltage. • One ammeter is provided to display the current.Specification
• Compressor :Hermatic • Capacity : 1/4 Ton • Supply : 230 V AC / 50 Hz • Condensor : 12 Coil • Evaporator : 15 Liter Capacity • Refrigerant : R134ASmart Energy Meter
A Smart Energy Meter based on Analog Devices IC has been developed to build an Advanced Metering Infrastructure (AMI). The AMI system facilitates networking capability via GSM, ZigBee and ModBus. A Smart Energy Meter Development system has been developed by us, which consists of 1φ/3φ measurement section, a 32-bit ARM controller, wireless modules and powerful software. The student can completely understand the concept and usage of this trainer. This can be also used as one of the IOT server node.
Features
• 3 Phase energy readings displayed in the Graphics LCD • Simple design, Efficient and Highly Accurate • Easy connectivity for various loads • Keys to change the settings • Supports GSM, ZigBee and ModBus for networking • LPC2148 based processing board • 32/16 bit ARM7TDMI-S CPU with 60MHz maximum CPU clock • On board peripherals for extension • Graphics LCD interfaced to display the energy readings • Keys for various settings • Current Sensors and Voltage Sensors provided to measure 3 phase voltages and currents • Polyphase energy metering IC provides highly accurate energy measurement • Energy metering IC interfaced via I2C with Controller module • CC2530 Controller with maximum 32MHz CPU clock • High-speed and low-power 8051 CPU • 2.5GHz IEEE 802.15.4 compliant RF transceiver upto 250kbps data rate • UART Connectivity to interface with CPUXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
CAVITY BLOCK
Corcyra Cage
Theramal Conductivity Of Insulating Slabs
The apparatus consists of a slab assembly. The main Heater and a radial guard heater are sandwiched between copper plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other Sides of the specimen. The radial guard heater ensures all heat of the main heater to pass axially through the specimens which is collected by cooling plates. By knowing the temperatures and Heat input, thermal conductivity of specimen can be calculated. The test set up is enclosed in an enclosure with insulation inside to provide undisturbed Surroundings. The design style of the apparatus is similar to as recommended in INDIAN standard. The difference is in sizes.
SPECIFICATIONS:
1.Heaters: a)Main heater plate 110 mm dia. with mica heater Sandwiched between copper plates. b)Radial guard heater plate I.D. 120mm and OD 200 mm mica heater sandwiched between copper plates. 2.Water circulated cooling plates -2 nos. 3.Dimmerstat-2 A capacity – 2 nos. to independently control Inputs to the heaters. 4.Measurements – A voltmeter and an Ammeter with selector switches to measure inputs,Multichannel digital temperature indicator to measure Temperatures at various points, having 0.1 °c least count. A technical manual accompanies the unit.SERVICES REQUIRED:
1.230 V, A.C. stabilized supply along with earthing connection. 2.Water supply of about 4-5 lit/min. 3.Bench area 1m x lm x O.5m height.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT