XTEMOS ELEMENT
AJAX PRODUCTS TABS
Spotting Plate
Description
FEATURES
Porcelain spotting plates made with high purity raw material. Uniform quality, resistant to acid and alkalai. Designed to withstand sudden temperature changes without cracks or deformation. Glazed surface with 21 mm diameter depressions. Under normal conditions, the glazed pieces can sustain a temperature of 1050°C.Available in
6 holes 12 holesLight Box and Optical Set
Description
A Robust light box in matt black finish with a 12 V 24 W axial filament lamp with flexible leads. One end of the box takes a cylindrical convex lens in an adjustable sliding mount to enable production of convergent, parallel or divergent beams. Complete with accessories which consist of: 5 Plastic blocks, one rectangular, One semicircular, One equilateral prism 60° x 60° x 60°, One right angle prism 90° x 60° x 30° and one right angle prism 90° x 45° x 45°. 3 Cylindrical acrylic lenses: one double convex, one double concave, both having the same radius of curvature and one thick convex lens. 3 Mirrors, one plane glass, one curved parabolic and one curved semi-circular. 2 Slit plates, one with three narrow and one narrow slits, the other with four narrow and one wide slits 1 Set of eight colour filters, Red, Green, Blue, Cyan, Violet, Yellow, Orange and Magenta. 1 Set of coloured cards, Red, Green, Blue, Violet, Orange, Cyan, Yellow and Pink. Complete with one spare lamp, in box.Induction Coil, Ruhmkorff
Description
Coils are wound with highly insulated copper wire impregnated with paraffin wax; input 6-8 V dc through two 4 mm socket terminals, with an adjustable trembler system. The spark suppression capacitor is housed in the base. A pair of pointer electrodes with insulated handles for adjustment of the spark gap is provided. Spark length 10 mm Spark length 25 mm Spark length 50 mm Spark length 75 mm Spark length 100 mmXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Vacuum Pump
Multiple Input/Output Process Trainer
Panel Features
• Power ON/OFF switch • Heater selection switch • Heater and pump indicators • High current fuse carrier for • Heater protection • Provision to run the stirrer • Digital panel meters • Two numbers of industrial PID Controller • Electrical test points are provided to measure the current signal • Mimic DiagramFeatures
• Two numbers of flow Transmitter (DPT) are provided to sense the flow of the liquid. • Three numbers of temperature transmitter (RTD) are provided at various stages to measure the temperature. • Five numbers of level sensor (RF capacitance) are provided to sense the level of each tank. • Industrial type Conductivity sensor is provided to analyze the conductivity of given Solution. • RTD sensor (or) Thermocouple acts as a temperature sensor. • Digital panel meters are provided to indicate the output of each sensor. • Provision to measure the conductivity. • Two numbers of motorized control valve or pneumatic control valve are provided to control the flow of the pipe line. • A powerful thyristor based power driver is provided to drive the heater power. • An industrial type water heater is used as a heat Source. • Storage tank of 50 litre capacity (SS). • Process tank of 15 litre capacity (SS). • Four numbers of acrylic tank are provided to study the response of four tank systems. • In necessary location Ball valve, globe valve and needle valves are provided. • Two numbers of stirrer are provided in the temperature process and alkaline process. • Three numbers of centrifugal pump (FHP) is used to circulate the water from storage tank. • Six numbers of rotameter are provided in the process inlet to visualize the real flow. • Regulated power supply is mounted in the panel. • All the flow lines are fitted by (SS) pipe fitting. • An over head tank is provided to give constant flow. • All the equipments are mounted in a rugged and mobile type metallic work station.Turbine/Pump Unit
Description
For use as a water turbine to drive a generator producing electricity or for use as a pump driven by a motor and raising a head of water to produce potential energy. The rotor has eight 'bucket' blades and is housed in a block turbine chamber with a clear Perspex front. Two inlet tubules (for turbine and pump operation respectively) and one outlet tubule are provided and the shaft carries a 15 mm. diameter pulley. With driving belt.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Light Dependent Resistor Unit (LDR)
Human Ear, Enlarged, 2 Parts
Human Ear, 3 Parts
Centrifugal Pump Test Rig
Centrifugal Pump Test Rig
Closed Circuit Type With S.S. Tanks, ISI Mark Pumps & Motors, Powder coated The closed circuit test rig consists of a “kirloskar make” monoblock centrifugal pump. The pump is provided with a vacuum gauge on suction pipe and a pressure gauge on discharge pipe. The gate valve is used to adjust the head on the pump. The discharge is measured by measuring tank / water flow meter. The input power is measured by energy meter.
Specifications:
l. Centrifugal monoblock- 1 h.p. 2. Pressure gauge and vacuum gauge for measuring the head. 3. Measuring tank of 400×400 x400 mm OR Water flow energy meter for measuring the discharge. 4. Stop watch. 5. Sump tank of sufficient capacity. 6. Energymeter to measure input power. 7. A technical manual accompanies the equipment.Features:
1. The equipment is coated with an attractive and anticorrosive powder coating. 2. The equipment consists of ISI standard (i) Monoblock ————————- Kirloskar make (ii) Energymeter ————————- Maxwell Jaipur make (iii) Water flow meter ————————- Kranti/Anand make.Services required :
(i) 440 v, 15 A, stabilized three phase A.C. supply. (ii) Floor area-2 mx2mxl.5m height (iii) Tachometer for speed measurement (can be supplied at extra cost)XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Orfice Mouthpieces Apparatus
DESCRIPTION:
An orifice is an opening made in the side or bottom of tank, having a closed perimeter, through which the fluid may be discharged. A mouthpiece is short tube fitted to a same size circular opening provided in a tank so that fluid may be discharged through it. Orifice and mouthpiece are used to measure the rate of flow of liquid. The apparatus is designed to measure the co-efficient of discharge of orifice & mouthpiece. The apparatus consists of a supply tank, at the side of which a universal fixture for mounting orifice or mouthpiece is attached. A centrifugal pump supplied the water to supply tank. Head over the orifice/mouthpiece is controlled by a by pass valve provided at pump discharge. A measuring tank is provided to measure the discharge. A gauge for measuring X and Y co-ordinates of jet from the orifice is provided, which is used to calculate Cv of orifice.SPECIFICATIONS:
[1] Supply Tank – 0.4 X 0.3 X 0.5m height [2] Orifice – 8mm and 10 mm. [3] Mouthpiece (a) LID = 4 (b) L/D = 1 (c) Bordas mouthpiece. (d) Convergent mouthpiece. [4] X-Y gauge for orifice jet co-ordinates. [5] Measuring tank of suitable capacity OR a calibrated water flow meter. [6] Sump tank of suitable capacity. [7] 0.5 HP pump with valve. A technical manual accompanies the unit.SERVICES REQUIRED:
[1] Flow surface 2 mtrs. X 1 mtr. X 1.5 mtrs. height. [2] 230 Volts, 5 Amp. Stabilized AC. Power Supply.Gas Turbine/Turbojet Engine
Two Stroke Petrol Engine Model
Corcyra Cage
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Monocot Stem T. S.
Level Process Station
Panel Features
• Digital Panel Meters. • Mimic diagrams. • Pressure gauges are provided, wherever necessary. • Level switches are provided for overflow indication.Features
• The Level Process Station is an attractive module. • All are the industrial (4-20) mA standard interfacing signals. • It provides a real industrial feeling of the processes to the students. • A RF Capacitance level transmitter is used to sense the level (700mm) of tank. • An Electronic Regulated Power supply is fixed for voltage regulation. • An Air regulator cum filter is provided to regulate the air pressure. • An Industrial standard electro pneumatic converter is mounted to control the control valve. • A Globe pneumatic control valve is used to control the flow rate • All the air flow lines are fitted by flexible hoses/fittings for better reliability. • A Rotameter (1000 LPH) is provided for Visual Indication of flow rate. • A Transparent Process Fiber tank (800mm) with graduated level scale. • A Solenoid Valve is provided for Load Disturbance study. • A Rust proof Reservoir Tank (SS) capacity of 45 Liter. • By pass line is provided to avoid pump over loading. • A Centrifugal Pump is used for water circulation. • All components are fixed in a mobile rack. • All water flow lines are fitted by SS pipes. • USB/Serial port data acquisition is provided.Exterior Angle of Regular Polygan
Open Wind Tunnel Apparatus
Technical Description
A wind tunnel is the classic experiment system for aerodynamic flow experiments. The model being studied remains at rest while the flow medium is set in motion, and thus the desired flow around the model is generated. Open wind tunnel used to demonstrate and measure the aerodynamic properties of various models. For this purpose, air is drawn in from the environment and accelerated. The air flows around a model, such as an aerofoil, in a measuring section. The air is then decelerated in a diffuser and pumped back into the open by a fan. The carefully designed nozzle contour and a flow straightener ensure a uniform velocity distribution with little turbulence in the closed measuring section. The flow cross section of the measuring section is square. The built-in axial fan with guide vane and a variable-speed drive is characterised by an energy-efficient operation at high efficiency. Air velocities of up to 28m/s can be reached in this open wind tunnel. The trainer is equipped with an electronic two-component force sensor.Lift and drag are detected and displayed digitally. The air velocity in the measuring section is displayed on the inclined tube manometer. The tube manometers is recommended for measuring the pressure curves in drag bodies. Extensive accessories allow a variety of experiments, for example lift measurements, pressure distributions, boundary layer analysis or visualisation of streamlines. The well-structured instructional material sets out the fundamentals and provides a step-by-step guide through the experiments.Learning Objectives & Experiments
– Determine drag and lift coefficients for different models – Pressure distribution when flowing around drag bodies – Boundary layer analysis – Investigation of flutter – Wake measurementFeatures
* Open wind tunnel for a variety of aerodynamic experiments * Homogeneous flow through the flow straightener and special nozzle contour * Transparent measuring sectionXTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















