Profile Projector 200mm Dia

Specifications

Bench type Profile projector is a highly precision instrument designed for most diversified jobs at industries & engineering colleges. It consists of antiglare hard glass SCREEN 200mm DIA with cross line rotatable through 360 degree with least count of 2 minute an arc. The working table is secured on a heavy hollow base provided with X-Y movement, travel upto 25 X 25 mm ,equiped with zero adjustment Micrometers of 25mm graduation having least count 0.005 mm.

Technical:

Colour: White
Work Stage:150 mm X 150 mm
Magnification:10 X
Travel X & Y:25 X 25 mm
Micrometer Head:0 to 25 mm with accuracy 0.005 mm/0.01 mm
Screen Dia:200 mm, 360 degree rotatable Frosted glass Screen graduated scale.
Illumination:12 volt-100 Watt (Counter), 6 Volt-2o Watt (Surface)
Power Required:220-230V AC, 50 Hz

Main Parts of Instrument :

Screen 200mm Dia with Cross Line. Clips to hold Drawing or films. 360 degree rotatable graduated ring. Surface Light Lamp. Objective (Projection Lens). Micrometer Head with least count of 0.005mm X-Y Stage travel upto 25 X 25mm Focusing Knob for up & down motion.

Human Upper And Lower Jaw without internal wall

Description

Showing various positions of teeth in the upper and lower jaws. Internal wall is removed to show the incisors, permanent canine and permanent premolars, molars, permanent incisors in full view and also the arteries, veins and nerves serving them on base with key card

Narrow Mouth Reagent Bottle

We are the well known Exporter and Trader of Narrow Mouth Reagent Bottle. Our Narrow Mouth Reagent Bottle are available in Polypropylene. The PP Narrow Mouth Reagent Bottle is Rigid, Translucent and have an Excellent Contact Clarity. The Narrow Mouth Reagent Bottle can be autoclaved filled as well as empty. The Polypropylene Cap has a built in seal ring to make the Narrow Mouth Reagent Bottle Leak Proof.
ParticularsPack (Pcs) 
Reagent Bottle (Narrow Mouth) 4 ml100 
Reagent Bottle (Narrow Mouth) 8 ml100 
Reagent Bottle (Narrow Mouth) 15 ml100 
Reagent Bottle (Narrow Mouth) 30 ml12 
Reagent Bottle (Narrow Mouth) 60 ml12 
Reagent Bottle (Narrow Mouth) 125 ml12 
Reagent Bottle (Narrow Mouth) 250 ml12 
Reagent Bottle (Narrow Mouth) 500 ml12 
Reagent Bottle (Narrow Mouth) 1000 ml6 
XTEMOS ELEMENT

AJAX PRODUCTS TABS SIMPLE

shirt-tab
Fashion
Featured
  • Featured
  • Man
  • Woman

Refrigeration Trainer Electrolux Type

This type of refrigeration is usually used for domestic purposes only as it is complex in the construction and working. This type of refrigerator was developed in 1925 by Munters and Battzervan when they were studying at Royal Institute of Technology At Stockholm for their undergraduate course. This type of refrigerator was known as three fluid refrigeration system. The elimination of aqua pump from the absorption system with the complete absence of moving parts and work input. The main purpose of removing the pump was to make the machine noiseless. It uses refrigerant as a solvent s and an inlet gas for inlet of the system. The inert gas is continued to the lower side of system only by its system. It is possible to maintain the uniform pressure throughout the system and after sometime permitting the refrigerant to evaporator at low temperature corresponding to its partial pressure. In the high pressure side system (generator and condenser), there exists only the refrigerant which is subjected to total pressure of the system so that it is condensed by using normal cooling water as air as it is done in other system. The strong aqua ammonia solution is heated in generator by the application of external heat source. The water vapor carried with ammonia vapor is removed in separate form as shown in figure. Then the dry ammonia vapor is passed into the condenser and it is condensed by using external cooling source. The liquid ammonia flows under gravity in the evaporator and it evaporates. The mixture of hydrogen and ammonia vapor is passed into the absorber and the weak solution from aqua ammonia from the separator is allowed to follow into the absorber, through tray this weak aqua ammonia solution comes into contact with hydrogen separated. This strong solution is further passed to the generator and it completes the cycle.

Blood Bank Rrefrigerator

Features

Temp Range/Precision : 4 ±1°C, 0.1 °C Control System : Microprocessor control Display Alarm : Large screen LED display/ Audio and visual alarm for Height or low temperature; System failure; Door ajar; Power failure Refrigeration Type : Forced air refrigeration system Door : Three-ply transparent glass door with lock, Heating film preventing frosting, Stealing joint strip with magnetic force Casters : 4 casters Power Supply : 110/220V±10%, 50/60Hz Capacity : 120L Refrigerant : R134a, CFC-Free Material Internal : Stainless steel Material External : Cold-rolled steel with anti-bacteria powder coating Drawers/Shelves : Shelves Consumption : 160W External Size(L*W*H) : 520*600*1050mm Standard Accessory : Temperature printer, 2 shelves, 6 baskets, fluorescent light

Specifications

Temperature- 2°C to 4°C Temperature Accuracy- + / - 1°C Temperature Controller- Digital P.I.D Controller Display- LCD / LED Display Alarm- Audio visual alarm for high and low temperature. Power Failure Alarm- Yes Refrigerant- Non-CFC Refrigerant Defrost type- Automatic Air Circulation- Forced air circulation External Construction- Stainless Steel 304 grades / MS Power Coated Interior Construction -Stainless steel 304 Insulation- CFC free high density polyurethane foam insulation Shelves- Adjustable and made of quality steel wire Illumination- Fluorescent Lamp Safety Device- High and low temperature protection Power Supply - 220 Volts

Electropneumatic Training

LIST OF EXPERIMENTS

1.Intoduction of Relay and Contactor. 2.Introduction of Proximity Sensor, Capacitive & Photoelectric Sensor, Limit Switch. 3.Introduction to Pressure Switch, Electrical Counter, ON Timer & OFF Timer. 4.Operation of single acting cylinder with single sol. valve and single limit switch. 5.Operation of double acting cylinder with single sol. valve and single limit switch. 6.Continuous operation of double acting cylinder with single solenoid valve and two limit switches. 7.Operation of double acting cylinder with single solenoid valve, AND gate of electrical switches. 8.Operation of double acting cylinder with single solenoid valve, OR gate of electrical switches. 9.Operation of double acting cylinder with single solenoid valve, NOR gate of electrical switches. 10.Operation of double acting cylinder with single solenoid valve, NAND gate of electrical switches. 11.Operation of double acting cylinder with double solenoid valve. 12.System pressure will be maintained in specified pressure limit with pressure switch. 13.Operation of double acting cylinder with single solenoid valve with ON time delay. 14.Operation of double acting cylinder with single solenoid valve with OFF time delay. 15.Continuous operation of double acting cylinder with specified no. of cycles using Counter. 16.Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Both Cylinder retracts simultaneously. A+, B+, (A-, B-). , Sequencing of Two Cylinders. Cycle is Cylinder A Extends, Cylinder B Extends, Cylinder A retracts then Cylinder B retracts. A+, B+, A-, B-

SALIENT FEATURES

1.Self combined mobile unit. 2.Only electrical supply required. 3.All the components are easily accessible. 4.Real life components of reputed manufacturers provided. 5.Quick connections possible due to special fittings/pipes. 6.Tried and tested components and circuits. 7.Specially designed electrical control panel enabling students to develop their own electrical circuits. 8.Completely user friendly and highly interactive software provided with PC based Trainer. 9.Modular design with facilities to operate simple mechanisms. 10.Pneumatically operated models available as additional supply. 11.Training of Trainers offered at regular intervals. 12.Two years performance guarantee for any manufacturing defects.

Burner Bunsen Natural Gas

Description

Nickel plated burner tube with rotatable air regulator and cylindrical connector. Mounted on pressure diecasted base. Base dia. 80 mm.

Burner Specifications :

Tube Dia. - 11 mm,
Height - 120 mm,
Weight - 260 g.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ALTERNATIVE

Fashion
Featured
  • Featured
  • Man
  • Woman

Horse shoe Magnet

Description

Economy chrome steel horseshoe magnet with keepers Horse sheo Magnet Alnico (Pair) Size are mentions below which we have :- 50 mm
75 mm
100 mm

Artery models

Empowered with the perfect combination of trained men and modern machines, we are able to manufacture, supply and export a wide range of Artery models. These products are used in different hospitals and medical centers for teaching students and physicians about the structure of arteries. With the help of our diligent team of skilled personnel, we are able to provide a unmatched range of these products. Owing to our team of trained logistics professionals, we are able to provide the clients with the on time delivery of Artery models.

Post Office Box, Wheatstone Bridge

Description

With two ratio dials of 10,100 and 1000 ohms each and a resistance arm of four dials, each of ten coils of 1, 10, 100 and 1000 ohms, giving total resistance of 11,110 ohms with 4 mm socket terminals for battery, galvanometer and unknown resistance. Highly stable resistances are used. Accuracy ±0.1%

Submercible Pump Test Rig

DESCRIPTION:

The Set-up is designed to study the performance of Submersible Pump. The Set-up consists of a Submersible Pump coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop oil circulation. Pressure and Vacuum Gauges are connected on delivery and suction side of pump for the purpose of measurement. The flow rate of water is measured using measuring tank and stop watch provided.

EXPERIMENT:

1. To determine overall efficiency and pump efficiency of the Submersible Pump 2. To plot Head vs. Discharge, Pump efficiency vs. Discharge.

FEATURES:

1.Closed loop water circulation 2.Compact & stand alone set-up 3.MS Excel sample calculation program on demand 4. Stainless Steel tanks and wetted parts 5. Superb painted structure 6.Simple to Operate & Maintain

UTILITIES REQUIRED:

1.Electric Supply: – Provide 230 +/- 10 VAC, 50 Hz, Single Phase Electric Supply with proper earthing. (Neutral – Earth voltage less than 5 VAC), 5 A, three pin socket with switch for pump. 2.Water Supply: Tap water connection ½ “ BSP, Distilled water @ 90 Ltrs. (Optional)

TECHNICAL SPECIFICATIONS:

1.Product : Submersible Pump Test Rig 2.Pump & Drive : Submersible Pump, Capacity 1 HP 3.Supply Tank : Capacity 90 Ltrs. MOC SS 4.Measuring Tank : Capacity 60 Ltrs. MOC SS fitted with Piezometer Tube & Scale 5.Piping : GI / PVC 6.Stop Watch : Electronic 7.Control Panel : With required electrical instrumentation The whole Set-up is well designed and arranged in a good quality painted structure
XTEMOS ELEMENT

AJAX PRODUCTS TABS ARROWS PAGINATION

shirt-tab
Electronics
Featured
  • Featured
  • Mobile
  • Smartwatches

Solar And Lunar Eclipse Apparatus

Description

Showing the Earth revolving around the Sun and the Moon around Earth. With a candle to represent Sun, manually operated.

Histology Set II

Set of 24 slides consisting of
Adrenal glandAreolar tissue
CereburmColon
Compact bone, LSHeart, entire LS
Human plantar skinHyaline cartilage
Kidney, LSLiver, injected
Lung, LS triple stainLymph node
Olfactory epitheliumOviduct
PenisPeripheral nerve
Pituitary, V.LSSperm Smear
Striated muscle, TSThyroid gland
ToothTrachea
UretervWhite Fibre-Cartilage

Paraffin Wax

Milky white wax for filling in above dissecting trays

Resistance Substitution Board

Description

Set of 12 different value resistor from 33 Ω to 10 M Ω. A rotary switch is used to select the required resistance, 4 mm sockets are provided for connections.
XTEMOS ELEMENT

AJAX PRODUCTS TABS WITH ICONS

Furniture
  • Furniture
  • Lighting
  • Accessories
  • Clocks
  • Cooking

2 Stroke Petrol Engine Sectional Working Model

Demonstration engine model is mounted on metal base with printed diagram. Ignition is shown by means of miniature bulb. Carburetor and fuel supply are sectioned. With a crank handle for manual operation.

Three Step Inductor

Description

This three step inductor consists of a coil of enamelled copper wire wound over an insulated spool. The coil consists of 4 layers of 200 turns each. The tappings at 200, 400 and 800 turns are brought out at 4 mm sockets. The output inductances at these tappings are as follows. No. of turns Resistance 200, Inductor 0.3 mH, Resistance 0.6Ω No. of turns Resistance 400, Inductor 1.2 mH, Resistance 1.2Ω No. of turns Resistance 800, Inductor 5.0 mH, Resistance 2.6Ω. One can easily change the inductor value of the instrument on just inserting a soft iron core inside the bobbin

CNC Lathe Trainer With Servo Drives

CONTROLLER:

(1) Type of control system: PLC based system (2) Main Spindle Drive : AC Motor with VFD (3) Z and X Drives : Stepper drive with RAMP function (4) Input to Stepper Motor : Optically Isolated (5) Motor Drive :TTL Compatible (6) Run Speed Control : Computer controlled through software (7) Interpolation : Liner / Circular / Parabolic (8) Cycles Used :G,M,S,T,F,I,K,M,F (9) Cycles : Circular Interpolation / Canned (10) Threading : Straight / Taper (11) Power Devices : Short Circuits and over Temperature Protected (12) Real Time Tool Path Simulation : Provided

MACHINE DETAILS:

(1) Center height : 100mm (2) Swing over Carriage : 80mm (3) Distance between Centre : 250mm (4) Longitudinal Travel : 250mm (5) Weight : 350 kg (6) Dimension in mm : 1100 x 750 x 1700 (7) Rapid Travel : 500mm/min (8) Resolution X & Z Axis : 10micron (9) Dt. Motor Power : 40V – 4A (10) Lubrication : Manual

SPINDLE:

(1) Spindle Speed : Continuous Variable (2) Spindle Power : 2 HP (3) Inside Taper : MT3 (4) Speed Range : 50 to 3000RPM

Thermal Conductivity Of Liquid

Thermal conductivity of is an important engineering property. The apparatus uses guarded hot plate method for determining thermal conductivity. It consists of hot plate i.e. an electrical heater sandwiched between two plates. The heat loss from hot plate is prevented by using two guard heaters and heat of removes heat from liquid by circulation of water. Input to heaters the temperatures.

SPECIFICATIONS:

1.Guarded hot plate assembly comprising of main heater, ring guard heater and top guard heater, mounted over the liquid test cavity. 2.Cold plate assembly provided with water connections. 3.The assembly is housed in an enclosure box with glass wool insulation. 4.Instruments panel consisting of : a).Digital voltmeter and ammeter of suitable range. b).Dimmerstat for controlling input to the heaters (2 amp. 3 Nos.) c).Multichannel digital temperature indicator.

SERVICES REQUIRED:

1.Floor space of about 0.75m. x 1.5m. at working height. 2.230v. AC electrical supply with earthling connection. 3.Water flow rate of about 10- 15 lit/min. at constant head.
XTEMOS ELEMENT

AJAX PRODUCTS TABS LOAD MORE PAGINATION

Featured
  • Featured
  • Lighting
  • Accessories

SILICA CRUCIBLE WITHOUT LID

PRODUCT DESCRIPTION
  • Crucible is glazed inside and outside.
  • Highly resistant to alkalis and hot temperatures
  • 50ml capacity
  • Outside diameter 55mm, 42mm height
  • No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML

SILICA CRUCIBLE TALL FORM Without Lid, Translucent

PRODUCT DESCRIPTION -Without lid, translucent, glazed - Ordinary type lids to be purchased separately Size/ dimension:
  • 20ml,  Dia. 35mm x Ht. 38mm
  • 30ml, Dia. 43mm x Ht. 38mm
  • 50ml, Dia. 51mm x Ht. 51mm

SILICA MUFFLE TRAYS (For VM Crucible)

PRODUCT DESCRIPTION:   Available in 2types:  Two Hole, 39mm Length Four Hole, 76mm Length