XTEMOS ELEMENT
AJAX PRODUCTS TABS
Monocot Root T.S.
Eye Model On Bony Base
Cytology
Description
All Charts are made on PVC rexine, hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall. Size 75×100 cm. Cell Membrane showing structure & functions Cell Wall, showing structure & functions Endoplasmic Reticulum showing structure & functions Mitochondrion – showing structure & functions Golgi Complex showing structure & functions Chloroplast – showing structure & functions Nucleus – showing structure & functions Chromosome – showing structure & functions D.N.A. – showing structure & functions R.N.A. – showing structure & functionsXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Human molar Teeth
Monocot Stem Anatomy T.S &L.S
Description
This model exhibits the various tissues and the scattered, closed and collateral vascular bundles in transverse and longitudinal sections in maize. The large pitted vessels, spiral and annular vessels show the cell wall thickenings in L.S. Useful model for teaching anatomy of monocot stem. Mounted on base with keycard.Tuning Forks welch type
Description :-
Consists of aluminum tuning forks, mallet in a wooden box.
Tuning forks are stamped with frequency and note.
Set of 8 (C-256, D-288, E-320, F-341.3, G-384, A-426.6, B-480, C-512)
Set of 13 (G-100, C-128, C-256, D-288, E-320, F-341.3, G-384, A-426.6, B-480, C-512, C-1024, C-2048 and C-4096)
Set of 8 (C-256, D-288, E-320, F-341.3, G-384, A-426.6, B-480, C-512)
Set of 13 (G-100, C-128, C-256, D-288, E-320, F-341.3, G-384, A-426.6, B-480, C-512, C-1024, C-2048 and C-4096)
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Torsion Of Rods Apparatus
INTRODUCTION:
A torsion test is quite instrumental in determining the value of modulus of rigidity of a metallic specimen. The value of modulus of rigidity can be found out thought observations made during the experiment by using the torsion equation.APPARATUS:
1. A torsion testing machine. 2. Twist meter for measuring angles of twist 3. A steel rule and Vernier Caliper or micrometerMicroprocessor Photo Colorimeter
Microprocessor Photo Colorimeter is a compact and easy to operate instrument for Photo Colorimeter analysis of any concentration.
The output is available on a 16 x 2 line alphanumeric backlit LCD display in terms of %Transmission (%T), Absorbance (Abs.), Concentration (Conc.) and K Factor.
This instrument has 100 sample storage memory and printer output facility for printing data with any dot matrix printer.
The use of microcontroller has made it extremely versatile and accurate instrument.
10 mm path length matched test tubes are used for sample and blank.
The use of high class standard wide range glass filters covering 400 to 700 nm give extremely good results.
The filter setting is controlled by a rotating disc having 8 filters.
An automatic shutter is provided to stop the light reaching the photocell, when test tube is not inserted in the tube holder.
This increases the life of photocell tremendously.
Facility has been provided to store the last K Factor and the standard concentration value.
User can also enter any known ‘Factor’ for a test, thereby eliminating the need to re-run the standards again and again.
Specifications
Wavelength Range | 400 - 700 nm | |
Resolution | %T: 1, Abs: 0.01, Conc.: 0.01, K Factor: 0.01 | |
Photometric Range | %T: 0 - 100, Abs: 0 - 1.99, Conc.: 0 - 1999, K Factor: 0 - 1999 | |
Detector | Wide range Silicon Photodiode/Photocell | |
Display | 16 x 2 line alphanumeric backlit LCD display | |
Keyboard | Soft Touch Membrane Keys | |
Data Storage | Up-to 100 Samples (0 - 99) | |
Light Sources | 6.8 V, 0.3 Amp Tungsten Lamp | |
Sample System | 10 mm path length matched glass test tube | |
Filters | 400, 450, 490, 520, 540, 570, 620, 680 nm | |
Printer Interface | Centronics Parallel Printer interface for Dot Matrix Printer | |
Serial Interface | RS-232C interface (optional available on request) | |
Power | 230 V ± 10% AC, 50 Hz | |
Dimensions | (L x B x H) 240 x 254 x 90 mm (Approx.) | |
Weight | 2.5 Kg (Approx.) |
Accessories
Matched Test Tube: A set of 5, Spare Lamp, Mains Lead, Operation Manual and Dust Cover.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Shunt Active Filter Trainer
Specification
• FPGA Spartan 3A DSP board used for generating the PWM signals. • Three phase 3 level diode clamped inverter used as a Active filter. • SRF (or) Instantaneous PQ theory will be used to generating reference current. • PI control or fuzzy logic will be used to regulate the dc link capacitor voltage. • Reference DC link Voltage will be 250V. • Hall effect current transducers used to sense the source currents, load currents and compensation currents. • Hall effect voltage transducers used to sense the dc link voltage and source voltages. • Necessary source inductor and filter inductor provided. • Input source Line voltage -200V (Peak). • Input source Current -10A (Peak). • Power Rating -3KW. • Reactive power compensation can be provided. • 3KW linear and non-linear loads will be given. • User can modify source, filter inductance and external loads. • User can modify control algorithm. • Industrial type cabinet provided. • Before compensation source current THD will be greater than 26% • After compensation source current THD - 2.5 - 4% in 3 level inverter - 4 - 5% in 2 level inverterBottle Filling Module
Specification
• One proximity sensor to detect the bottle presence • Opto coupler sensor to detect the bottle position. • A mechanical base fixed with stepper motor and gear mechanism provided to hold 5 bottles and rotate in circular motion. • A tank is provided to store the liquid. • One solenoid valve to control the volume of liquid flow into the bottle. • One Reservoir tank with FHP pump to feed the water to supply tank. • Two magnetic switches provided to maintain the level of water in supply tank.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Shell Tube Heat Exchanger Water To Water
Heat exchanger is the devices used to transfer the heat from one fluid to other. The shell and tube heat exchanger is two tube single pass heat exchanger. The hot fluid is hot water obtained from water heater. The coil fluid is cold water. The schematic flow arrangement is shown in figure. Hot water enters the lower side of end box, flows through the tubes in lower half of shell and comes to the other end of the shell. It reverses its direction, flows through tubes in upper half of the shell and leaves out. Cold water enters lower part of the shell passes over the tubes between the baffles and leaves out the shell through outlet at upper surface of shell.
SPECIFICATIONS:
1.Shell – 150NB, 750 m.m. long provided with end boxes. a.One end box with divider plate. b.25% cut baffles – 4 Nos. in the shell. 2.Tubes – 4.5mm I.D., 6.35mm O.D.,250 m.m. length copper tubes with triangular pitch. 3.Instantaneous water heater, 3 Kw capacity, to supply hot water. 4.Thermometer for measuring the water temperature. 5.Valves to control hot and cold water flow.SERVICES REQUIRED:
1.3 P H, AC supply 2.Floor space 1.5m. X 1m, 3.230V, 15A, AC supply with earthing connection. 4.Water supply at the rate of about 10 lit/min at constant heat.Microscope Glass Slides – Frosted
three-phase-flying-capacitor-5-level-inverter-power-module
Specification
• Power circuit consists of 24Nos, 1200V, 20A IGBT with proper heat sink and snubber circuit. • 18 Nos of flying capacitor provided • 6 Nos, Power Diode @ 500v is provided for power circuit • 24 Noshigh speedopto-isolator provided for IGBT PWM inverter. • 24 Nos IGBT gate driver IC provided for IGBT gate driving • 22 nos isolated +15v dc @ 0.5A capacity provided for control circuit • One no of 3phase diode bridge rectifier@1200V, 20A with capacitor provided for input AC-DC conversion • 3 no of Hall Effect current sensor provided for O/P current measurement & protection circuit • 1 no Hall Effect current sensor provided for DC current measurement • Two no FRC connector provided for IGBT PWM input & ADC interface • MCB protection for input power ON/OFF & protection • One no of restart switch and LED provided for protection circuit indication & reset the unit • One Number of analog DC voltmeter provided for DC voltage measurement. • One number of power ON/OFF switch provided. • 3 Phase outputs & 3 Phase inputs are terminated in the front panel. • Test points provided for PWM input and current sensors outputXTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT