XTEMOS ELEMENT
AJAX PRODUCTS TABS
DC Network Analyzer
Specification
• Here we provide the bi-polar Transmission Line. • Simulated long, medium & short distribution lines selectable by patching in various length of DC Transmission line • Two no of bi-polar DC generator sources with ON/OFF control and voltage regulator potentiometer. - Two wire or Three wire Transmission Line operated in +12V DC - Each DC generator are independently control by potentiometer. • 2 digital voltmeters and ammeters provided in the input side and 2 digital volt meters and ammeters are provided in the output side • of transmission line to read the input & output parameters of transmission line. • One no of microcontroller based measuring system provide to read the input and output parameters. • 4 nos of digital ammeters provided to read the load current • 4 nos of resistive load and 4 nos of lamp loads are provided to load the transmission line.PLC-SIE2 with Demo Panel Training Kit
This trainer consists of PLC, Demonstration Panel & Programming Software.
PLC Specification
• Make : SIEMENS • Model : CPU1212C • Digital Inputs : 8 Nos • Digital Outputs : 6 Nos • Program Memory : 24KB • Data Memory : 10KB • PLC to PC interface : PROFINET • PWM & HSC channels provided • Windows based programming software providedPanel Specification
• SPDT switches provided for Digital inputs • LEDs provided with fuse protection for Digital outputs • Inbuilt 24V DC power supply provided • Connectors provided for external interface applicationsXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Decade Inductance Box – 3 Dial
CONDUCTIVITY METER
PRODUCT DESCRIPTION
All aqueous solutions conduct electricity to some degree. The measure of a solution's ability to conduct electricity is called "conductance" and is the reciprocal of resistivity (resistance). Adding electrolytes such as salts, acids or bases to pure water increases conductance (and decreases resistivity)
Conductivity Meter – Bench Top
Features:- Highly Stable & Accurate
- Cell Constant Adjustment Facility
- 3½ Digit Display
- Available in Laboratory & Field Models
- Automatic Temperature Compensation Facility
- Max Make, Table Pattern 6
- Pen Type (TDS/EC) Imported
- E.I Make, Model Alpha 06
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Bending Moment & Shear Force Apparatus
INTRODUCTION:
Shear Forces occurs when two parallel forces act out of alignment with each other. For example, in a large boiler made from sections of sheet metal plate riveted together, there is an equal and opposite force exerted on the rivets, owing to the expansion and contraction of the plates. Bending Moments are rotational forces within the beam that cause bending. At any point within a beam, the Bending Moment is the sum of: each external force multiplied by the distance that is perpendicular to the direction of the force.EXPERIMENT MANUAL:
1. To verify the Shear force a cross-section of the beam. 2. To verify the bending moment in cross–section of beam with a flexure condition.APPARTUS SPECIFICATION:
1. Dimensions : 158 cm X 45cm X (h)60cm 2. Total Beam Length : 160 cm with flexure 3. Width of Beam : 5 cm 4. Distance of Length in between : 5 cm 5. Height of beam : 36 mm 6. No. of Hanger for weights : 3 7. No. of Spring Balance : 2 (of 10kg) 8. Total Weight of Apparatus : 13.1 kgACCESSORY REQUIRES:
1. Shear force apparatus 2. Bending Moment Apparatus 3. Hangers 4. Weights 5. Two Spring balances – 10kgsTest Tube Caps
The Test Tube Caps offered by us, come with a transparent polypropylene cap for test tubes, which proves to be an excellent protection to the contents of the tubes.
The grooves inside the cap tighten the fitting on the tube while the outer set in the tube making the combination a leak proof one.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Test Tube With Screw Cap 16 x 100 mm | 500 | |
Cap For Test Tube Ø 25 mm | 500 |
Combined Object and Receiving Screen
Water Table Model
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Phase Shift Keying Modulation and Demodulation
This Instrument is design to demonstrate the method to transmit signals via. Electromagnetic transmission and to study the Phase Shift Keying Modulation and Demodulation. Whole instrument is placed in plastic moulded box and 2 mm banana plug leads are provided for modulation and demodulation connections.
Technical Specification:-
1. Fixed Output DC Regulated Power Supplies of ±12 V and ±5 V.
2. Built in Carrier wave Generator (Sine Wave) of 5 Vpp, 22 KHz ± 5% Frequency range with output on sockets.
3. Built in Data Generator using IC 7490 with four modulating signal outputs on sockets.
4. IC TL084 & IC 7486 are using for PSK demodulator.
5. Circuit diagram is printed on the milky white top panel and important connections are brought out on the sockets.
Newton’s Rings Apparatus
Electric Motor St. Louis
Description
The motor consists of a two pole armature mounted between the ends of two bar magnets. The armature has a two section commutator and a pair of slip-rings on its shaft and is so constructed that the wire cannot slip off the iron core. The upper bearing and brushes for the commutator are mounted on a strong upright. Separate brushes are provided for the commutator and for slip rings and each are connected to a terminal. The magnets are held in position by thumb screws.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Half Wave / Full Wave And Bridge Rectifier Apparatus
Objective : To study Efficiency and Ripple factor in case of Half wave, Full wave and Bridge rectifier on application of load and filters.
Features : Instrument comprises of AC Power Supply, 3 meters to measure Output Voltage, Output Current and ripple factor on electronic AC Voltmeter, 4 PN Junction Diodes, Filter Circuit kit, load Resistances selectable using bandswitch and all important connections points at 4mm Sockets.
Optional Acc : Digital AC millivoltmeter.
Tubing, Silicon
Bell Jar and Vacuum Pump Set
Description :- Simple, innovative kit allows you to perform a number of experiments on vacuum and air pressure.
The kit clearly demonstrates the method by which a pump works.
Also illustrates that air has mass and helps find its mass and density.
Explain the effect of surrounding air pressure on a sealed balloon.
The balloon will expand when the surrounding air is removed.
And also demonstrate that liquid boils at reduced temperature when the surrounding air pressure is reduced with instructions.
Leopold Maneuvers Simulator
Description
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees Fetal baby may be placed in normal, breech, or transverse position Fetal baby cradled between two “cushions” Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy The Palpation Module is designed to be used with the Advanced Childbirth Simulator.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT