Binocular Microscope
The future of class room microscopy with crisp sharp image, very much convenient in working, easy to move, light weight, durability, ergonomic design and affordable prices.
It became an ideal instrument for school labs, medical institutes, colleges and universities.
Specifications
Viewing head | : | Inclined sliding type Binocular Head | |
Eyepiece | : | Paired Wide Field Eyepiece WF 10x/18 | |
: | Paired Eye-piece 5x Huygenian | ||
Objectives | : | Semi-Plan 4x,10x,40x(SL) & | |
: | 100 x (SL) Oil Immersion. | ||
Nose-piece | : | Quadruple Nosepiece | |
Mechanical Stage | : | Double plate stage size 140mm x 140mm, X/Y travel range 90mmx65mm.Low drive right side movement controls. Ceramic surface for scratch resistance. Double specimen holder clip | |
Condenser | : | Abbe N.A 1.25 with Iris Diaphragm | |
Filter | : | Frosted White Filter | |
Illumination | : | LED Illumination, Brightness Adjustable | |
Light Source | : | Plano-concave Mirror | |
Carrying Case | : | Styrofoam Packing with standard accessories. |
Flasks, Volumetric, with Interchangeable Glass Stopper
Cryo Bath
Cryo Bath are one of the very important equipments which are used in several laboratory utilities.
These cryo baths are generally used for the purpose of freezing down the tissue samples at drastically low temperatures in very quick span of time while keeping the samples intact, distortion free and free from microscopic ice crystals.
Features
Micro-controller based temperature controller for temperature control. The unit is mounted on castor wheels for ease of mobility. Circulating pump for uniform temperature. Cabinet construction with stainless steel interior tanks to withstand critical applications. Audio visual alarm for controlling temperature deviation from preset temperature. Display of set value & process value. Integrated industrial strength pump for internal circulation. Temperature uniformity throughout the liquid medium. Rounded corners for better water circulation, improved uniformity and easier cleaning. Foam in placed PUF insulation for improved temperature stability and energy efficiency. 316 stainless steel construction for resistance against chemicals and simplified cleaning. Long-life heating elements for quick response to controller. Attractive front panel bezel for easy cleaning. GMP model: Inner chamber is made of 0.8 mm thickness and outer is of S.S 304, 1.0 mm thickness. NB: Specifications are subject to change without prior notice.Below mentioned are other details of our range of Cryo Bath
Operating Voltage | 230 V AC | |
Heating Power | 1250 W. | |
Protection Fuse | 10 amps. | |
Temperature | 0 to 40 °C | |
Accuracy | ± 0.2 °C |
Dissecting Microscope with Bull Lens
Specifications
Heavy stable round base, Focusing done by Rack & Pinion system, with stopper to limit the downward movement of the Eye piece towards stage. A adjustable holder is provided for moving magnifying lens over full area of the stage. It is easily replacable with Bull Eye Lens 80mm in dia. A plano concave mirror in fork mount for light reflection, sturdy removable hand rests and arrangement for inserting Black & white plate. Duly packed in wooden cabinet with the following optics:Eye piece: | 10x & 15X and Bull Eye Lens 80mm dia. | |
Stage size: | 100mm x 100mm |
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Anaerobic Culture Jar
Description
Transparent Anaerobic Culture Jar of 3.5.lit. capacity which is made of Polycarbonate. The lid of the jar is made of Aluminum pressure die Casting fitted with Pressure Valve, Vacuum Valve, Safety Valve & compound Pressure cum vacuum gauge, three finger aluminum clamp and sealing "O" ring. This is recommended only where inside air of jar is removed thru vacuum pump and CO2 is filled in the jar thru CO2 gas cylinder to generate anaerobic condition in the jar. Also supplied with plain aluminum pressure die casted lid which can be fitted when readymade gas packs are used to generate the anaerobic conditions inside the jar. When readymade gas packs are used, there is no need of lid fitted with dial gauge etc., for extra life of equipment.IoT Development System
The industrial networks are primarly concerned with Programmable Logic Controllers(PLC),Distributed Control Systems(DCS), Supervisory Control and Data Acquistion Systems(SCADA) any many other hetrogenous devices in the form of differnt applications. More over these devices are based on either wired or wireless communication protocols like Profinet, Profibus, MODbus, WiFi, Zigbee and Etc.
Specification:
• To impart the knowledge about Industrial IoTa the Students, We have designed a IIOT trainer kit, which have inter-quark chip based IoT Gateway. • This Gateway is a universal Gateway supports many different types of communication protocols such as wired and Wireless communication for industrial applications. • The IIoT Gateway connected with Siemens based Distributed Control System(DCS), Programmable Logic Controller(S7-1200, S7-1500) using S7-protocol and OPC UA. • The Intel centrino based powerful WiFi chip enables us to the access data via Mobile Application. • The Gateway can get the internet connectivity via Ethernet and WiFi also. • This Gateway can communicate with our own ingenious data acquisition system using RS485 BUS and RS232 Bus. • The USB based communication exchange the data between Zigbee co-coordinator and Gateway.Magnetic Field Apparatus
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Polariser and Analyser (Polaroid)
Pipette Stand, Wooden – Horizontal
Spectrometer, Standard
Description
Reads to 6 minutes of arc (0.1°) 170 mm diameter metal scale graduated 360° x 1°, independently rotatable, with locking screw, vernier attached to the telescope reads to 0.1° (6 minutes of arc). Collimator is mounted on a fixed pillar, with an achromatic objective of 150 mm focal length and 21 mm aperture, and has an adjustable slit 6 mm long. The telescope is on a movable pillar, with a fine adjustment screw, an achromatic objective of 170 mm focal length, 21 mm aperture, Ramsden eye-piece and glass crosswire graticule. Both collimator and telescope have spiral focusing system and have axis adjusting arrangement. The table has 3 leveling screws, with lines marked to assist prism placement. With prism and grating holders, one small screw driver and one Tommy bar for axis adjustment Without prism.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Survey Compass
Description
• Compass survey is a method of surveying by taking bearings and linear distances to produce plan. • Bearing is measured using prismatic compass, while the linear distance is measured using measuring tape. • Bearing in compass surveying means angle is made by chain line or survey line by referring it to magnetic meridian or magnetic north.Fiber Optics Communication Set
Objective:
To construct an optical transmitter and transmission of signal through Fiber Optics Cable. To construct an Optical Receiver and study the Attenuation of Signal when transmitted from Transmitter to Receiver end. Analog and Digital link can also be studied as this unit is complete with Sine and Square Waves. Bending losses can also be studied.
Features:
Instrument comprises of Microphone Preamplifier stages consists of MIC (Microphone), Preamplifier and Amplifier (Voice is converted to electrical signal and then amplified) and fed to LED (Transmitter) and then through fibre cable, signal is sent to Photodetector (Transistor) and again amplifier and output is sent to Speaker Unit. Power Supply of +6 VDC is used in Amplifier ckt. 2 No. Fiber Optics cables are provided (one of them is 50 cm long and the other is 100 cm long). One more fiber cable of 50mm length having connector at one end is also provided. Connectors a both end of fiber cable are provided for insertion in sockets provided on the front panel. Bending losses can also be studied in long wire.
Standard: MIC with 2 meter long lead and a Speaker 4, 4 ohm are mounted in a vertical box.
Accuracy: with 1 meter long connecting leads. 2 No. Fiber optic cable having length of 50 cm and 100 cm are provided.
Optional : Digital multimeter (3 1/2 Digit, Big size Display) This model also include Digital Multimeter and wooden frame for measurement of Numerical aperture i.e. complete in all respect including facility for measurement of numerical aperture.
Medical Microscope
Specification
Medical Microscopes is a straight tube monocular research microscope. The body can be inclined up to 90° with separate coarse and fine adjustment. Triple revolving nose-piece, double lens condenser numerical aperture of 1.2 with iris-diaphragm and rack-n-pinion adjustment. Fixed slide stage with detachable mechanical stage, plano-concave reflecting mirror inter-changeable with removable LED microscope lamp. With 10x, 15x or 5x hymenia eyepieces (2 Nos.) 10x, 45x, 100x oil-immersion (spring loaded) achromatic objectives. Magnification : up to 1500x.Study Of Flow Measurement Devices
Measurement of liquid flow is required at various places and for various purposes. Different types of flow measuring devices are used depending upon the system conditions, accuracy required, skill of operator and economy desired. The unit demonstrates some of the flow measurement devices.
SPECIFICATIONS:
[1] Intergratiry Type Turbine flow meter. [2] Glass Tube Rotameter. [3] Orificemeter differential manometer. [4] Venturimeter [5] Measuring Tank [6] Stop Watch (Digital) [7] 112 HP Monoblock Pump. [8] A differential manometer. [9] Sump tank of suitable capacity. A technical manual accompanies the unit.SERVICES REQUIRED:
[1] Flow surface 2 mtrs. X 1 mtr. X 1.5 mtrs. height. [2] 230 Volts, 5 Amp. Stabilized AC.Power SupplyXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Heat Pipe Apparatus
Heat Pipe Apparatus:
Heat pipe is an interesting device, which is used to transfer heat from one location to another.
The apparatus consists of three pipes, viz. A heat pipe, copper pipe and stainless steel pipe. Ail the pipes have same physical dimensions. Copper and stainless steel pipes serve the purpose of comparison of heat pipe performance. All pipes are mounted vertically with a band heater at lower end and water filled heat sink at upper end. Nearly isothermal operation of heat pipe is clearly visualized from longitudinal temperature distribution of the pipe.
SPECIFICATIONS:
1.Heat pipe – Stainless Steel pipe, 25 mm O.D., 450 mm. Long. Sealed at both ends, evacuated and filled partially with distilled water – one No. 2.Copper and stainless steel pipe of same size as that of heat pipe – one each. 3.Equal capacity heater at bottom end of each pipe. 4.Water filled heat sinks at upper end of each pipe.Measurements and controls
a) Dimmerstat to control heat input to all the heaters – 4 amp. Capacity One No. b) A voltmeter and an ammeter to measure input to heaters One each. c) Multichannel digital temperature indictor to measure temperatures along the length of pipes.Four thermocouples are provided on each pipe. v Thermometers to note down water temperatures in heat sinks – 3 Nos.Services Required:
230 VA.C. Single Phase supply. Floor Area = 1 m X 0.5m X 0.5 m height.Vernier Calipers Double Scale
Magnetic Numbers
Handheld GPS
Description
We offer all varieties of portable handheld GPS, hand held GPS systems and export all varieties of GPS, presently used by people around the World. Area measurement using hand-held gps. simply walk, ride, drive or fly around the perimeter, and press a button simple. Handheld gps at the gps store, inc. your source for garmin gps map 62, garmin oregon and montana handheld gps, magellan explorist units, gps map receivers and more.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent