XTEMOS ELEMENT
AJAX PRODUCTS TABS
Zener Diode Unit
Funnel Holder
The Funnel Holder offered by us is made of Polypropylene.
The corrosion free Funnel Holders can hold funnels with diameter 3" to 6".
The extra plate provided can be placed to hold funnels bearing diameter 1" to 3".
Two tapered wedges are provided to ensure firm grip on Rods having diameter ½" or 3/8".
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Funnel Holder - Single | 12 | |
Funnel Holder - Double | 6 | |
Seperatory Funnel Holder | 12 |
Pelton Wheel Turbine Test Setup
DESCRIPTION:
Pelton Wheel Turbine is only impulse water turbine now in common use named in honor of Sir L.A. Pelton (1829-1908) of California, USA. It is a tangential flow impulse turbine. The water strikes the buckets along the tangent of the runner. The energy available at the Inlet of the Turbine is only kinetic energy. The Pressure at the Inlet and Outlet of the atmospheric. This turbine is used for high heads. The Present Set-up consists of a runner. The buckets are mounted on the runner. The water is fed to the turbine, through SS nozzle with a SS spear, by means of Centrifugal Pump, tangentially to the runner. Row of water into turbine is regulated by adjusting the spear position by the help of a given hand wheel the runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. The circular window of the turbine casing is providing with a transparent acrylic sheet for observation of flow on to the buckets. This runner assembly is supported by rigid MS structure. Load is applied to the turbine with the help of this brake dynamometer so that the efficiency of the turbine can be calculated. Pressure Gauge is fitted at the Inlet of the turbine to measure the total supply head to the turbine.EXPERIMENT:
1.To study the operation of a Pelton Wheel Turbine 2.To determine the Output Power of Pelton Wheel Turbine 3.To determine the Turbine EfficiencyUTILITIES REQUIRED:
● Water Supply and Drain.● Electricity 15 kW, 440V AC, Three Phase
TECHNICAL SPECIFICATIONS:
MODEL | HM 111 (1.33 HP) | HM 111 (2 HP) | HM 111 (5 HP) |
Output Power | 1.33 HP / 1 Kw | 2 HP / 1.5 Kw | 5 HP / 3.75 Kw |
Discharge | 300 LPM (Approx.) | 400 LPM (Approx.) | 630 LPM (Approx.) |
Supply Head | 25 m | 40 m | 45 m |
Rope Brake Dynamometer | Dia 200 mm | Dia 200 mm | Dia 300 mm |
Sump Tank | Capacity 150 Liters. | Capacity 200 Liters. | Capacity 300 Liters. |
Water Circulation Centrifugal Pump | Capacity 5 HP, Three Phase | Capacity 7.5 HP, Three Phase | Capacity 15 HP, Three Phase |
Speed | 1000 RPM (approx.) | ||
Impeller | Material Brass, Bucket type | ||
Nozzle | Material Stainless Steel/Mild Steel | ||
Spear | Material Stainless Steel/Mild Steel | ||
Discharge Measurement | Pitot Tube with Manometer | ||
Control Panel | Star/Delta Starter, Mains Indicator, MCB for overload protection | ||
The whole set-up is well designed and arranged in a good quality painted structure. |
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

francis turbine test setup
DESCRIPTION:
Francis Turbine is a reaction Turbine, which was developed by English born American Engineer Sir J.B. Francis. The water enters the turbine through the outer periphery of the runner in the radial direction and leaves the runner in axial direction and hence it is called a mixed flow turbine. As the water flows to the runner, a part of pressure energy goes on changing into kinetic energy. Thus the water through the runner is under pressure. The runner is completely enclosed in an air tight casing and the casing & runner is always full of water. The present Set-up consists of a runner. The water is fed to the turbine by Means of centrifugal Pump, radially to the runner. The runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. The circular window of the turbine casing is provided with a transparent. The circular window of the turbine casing is provided with a transparent acrylic sheet for observation of flow on to the runner. The runner assembly is supported by thick cast iron pedestal. Load is applied to the turbine with the help of brake arrangement so that the efficiency of the turbine can be calculated. A draught tube is fitted on the outlet of the turbine. The Set-up is complete with guide mechanism. Pressure and vacuum Gauge are fitted at the Inlet and Outlet of the turbine to measure the total supply head on the turbine.UTILITIES REQUIRED:
● Water Supply and Drain.● Electricity 15 kW, 440V Ac, Three Phase
TECHNICAL SPECIFICATIONS:
MODEL | HM 101 (1.33 HP) | HM 101 (2 HP) | HM 101 (5 HP) |
Output Power | 1.33 HP / 1 Kw | 2 HP / 1 Kw | 5 HP / 3.75 Kw |
Discharge | 1000 LPM (Approx.) | 1000 LPM (Approx.) | 2000 LPM (Approx.) |
Supply Head | 10 m | 10 m | 15 m |
Rope Brake Dynamometer | Dia 200 mm | Dia 200 mm | Dia 300 mm |
Sump Tank | Capacity 300 Ltrs. | Capacity 300 Ltrs. | Capacity 600 Ltrs. |
Water Circulation Centrifugal Pump | Capacity 5 HP, Three Phase | Capacity 5 HP, Three Phase | Capacity 15 HP, Three Phase |
Speed | 1500 RPM (approx.) | ||
Runner | Having Curved Vanes | ||
Discharge Measurement | Pitot Tube with Manometer | ||
Control Panel | Star/Delta Starter, Mains Indicator, MCB for overload protection | ||
The whole set-up is well designed and arranged in a good quality painted structure. |
Measuring Jugs
The Measuring Jugs, moulded in Polypropylene are clear, autoclavable and have good chemical resistance.
The Measuring Jugs are provided with a handle for easy & convenient lifting and have raise graduations for easy reading.
Adding to the existing range of Jugs, these short form transparent jugs, made of polypropylene are autoclavable and have non-drip spout.
These jugs have raised graduations, provide excellent contact clarity, & are provided with excellent thumb grip on handle.
Material : Polypropylene
Particulars | Pack (Pcs) | |
---|---|---|
Measuring Jug 250 ml | 12 | |
Measuring Jug 500 ml | 12 | |
Measuring Jug 1000 ml | 6 | |
Measuring Jug 2000 ml | 6 | |
Measuring Jug (Euro Design) - 500 ml | 12 | |
Measuring Jug (Euro Design) -1000 ml | 6 | |
Measuring Jug (Euro Design) - 2000 ml | 6 | |
Measuring Jug (Euro Design) - 3000 ml | 6 | |
Measuring Jug (Euro Design) - 5000 ml | 4 | |
Measuring Jug (Printed Graduation) - 100 ml | 12 | |
Measuring Jug (Printed Graduation) - 250 ml | 12 | |
Measuring Jug (Printed Graduation) - 500 ml | 12 | |
Measuring Jug (Printed Graduation) - 1000 ml | 6 | |
Measuring Jug (Printed Graduation) - 2000 ml | 6 | |
Measuring Jug (Printed Graduation) - 5000 ml | 4 |
Male Catheterization Training Simulator
Description
Catheterization Trainer Simulator trainer, male bladder catheterization procedures can be realistically demonstrated, practiced and assessed. The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.The material is soft and flexible:
the foreskin is movable and the penis can be stretched. This way the student can practice all the necessary gestures for catheterization (e.g. disinfection). The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.Various levels of difficulty:
On the male insert, three different levels of prostate narrowing can be set. In the narrowest case, the student can feel that catheterization is no longer possible through the urethra and that a suprapubic catheter will have to be inserted. A suprapubic catheter has already been put in place and the student can practice cleaning it and taking care of it with the trainer.All the benefits of the male catheterization simulator at a glance:
Male catheterization with realistic resistance 3 levels of adjustable prostate narrowing soft and movable foreskin (for practicing disinfection, for example) Anatomically realistic pelvic structure Liquid outflow if catheterization is successfully carried out The transparent bladder can be checked and the abdominal wall can be removed Includes suprapubic catheter for practicing, cleaning and caring for it. Stands securely on the table thanks to the non-slip feet Magnetic connectors for quick set-up and dismantling Easy to clean and maintain, and can be completely taken apart A sponge on the inside prevents a build-up of moisture.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
White Board Optics Set
Description
An economical and comprehensive set of equipment for ray optics and color experiments using magnetic-backed components that can be used on the whiteboard (included) or any installed steel (magnetic) board. Included a double ended light box contains a 12 V / 20 W halogen lamp, a wall-mount AC adapter, one end carries a cylindrical lens and slots for mounting the three slit diaphragms for ray optics. The other end carries two adjustable mirrors and an open area for color mixing work using colored filters that fit into slots in the ray box, Seven transparent color filters, seven opaque color filters, Three slits, one rectangular acrylic block, one semicircular block, one right angle 90° x 45° x 45°, One right angle 90° x 60° x 30°, one equilateral prism, four plastic coated ring magnets, one double convex block, One mirror strip, one double concave lens, two magic alphabet card and one mirror holder With instruction manual. The sizes of whiteboard supplied are approx. 580 x 390 mm.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Heat Pipe Apparatus
Heat Pipe Apparatus:
Heat pipe is an interesting device, which is used to transfer heat from one location to another.
The apparatus consists of three pipes, viz. A heat pipe, copper pipe and stainless steel pipe. Ail the pipes have same physical dimensions. Copper and stainless steel pipes serve the purpose of comparison of heat pipe performance. All pipes are mounted vertically with a band heater at lower end and water filled heat sink at upper end. Nearly isothermal operation of heat pipe is clearly visualized from longitudinal temperature distribution of the pipe.
SPECIFICATIONS:
1.Heat pipe – Stainless Steel pipe, 25 mm O.D., 450 mm. Long. Sealed at both ends, evacuated and filled partially with distilled water – one No. 2.Copper and stainless steel pipe of same size as that of heat pipe – one each. 3.Equal capacity heater at bottom end of each pipe. 4.Water filled heat sinks at upper end of each pipe.Measurements and controls
a) Dimmerstat to control heat input to all the heaters – 4 amp. Capacity One No. b) A voltmeter and an ammeter to measure input to heaters One each. c) Multichannel digital temperature indictor to measure temperatures along the length of pipes.Four thermocouples are provided on each pipe. v Thermometers to note down water temperatures in heat sinks – 3 Nos.Services Required:
230 VA.C. Single Phase supply. Floor Area = 1 m X 0.5m X 0.5 m height.Porcelain Desiccator Plates
Main Voltage Coils, For Demountable Transformer
Siemens IoT 2020 Gateway
Specification:
• SimaticIoT 2020 Educational Intelligent gateway • Intel Quack Soc x 1000 • 400MHz operating frequency • Micro SD card slot, upto 32GB • 512MB RAM, 8MB Flash, 256KB SRAM • One USB controller and one USB device • FTDI USB to serial Interface • One no of 10/100Mbps Ethernet • Arduino Uno R3 compatible expansion slot • One mini PCIe expansion slot for WLAN/additional Ethernet port • Yocto V2.1 based Linux operating system • Input supply 24V DC • Programming in high level language • Support for various protocols like Modbus RTU, POC UA and cloud protocols like MQTT/AMQPXTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Wire helix (Slinky)
Three Phase Transmission Line Fault Analysis Trainer
Three phase Transmission line fault Simulation Study Module
Specification
• 3 phase power supply from 3 phase generator • To simulate 3 phase balanced system fault and unsymmetrical faults • Fault study with single line and double line in 3 phase system • Faults : - L-G-Fault - L-L-Fault - L-L-G-Fault - Single Conductor open fault - Double Conductor open fault - Fault through impedance • Theoretical calculations and verification with practical results. • The transmission lines are simulated by high frequency Inductance & resistance for short, medium and long line.Lamp Unit, Triple
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT