XTEMOS ELEMENT
AJAX PRODUCTS TABS
Cold Chisels
Vacuum Delivery Model
Description
The model basing on the mechanism of normal labor shows the cardinal movements of engagement. Descent-flection-internal rotation of the head-extension-retitution-external rotation of the head-internal rotation of the shoulders at accouchement. Suitable for teaching the mechanism of normal labor in medical colleges and nursing schools.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Pipes, Resonance Demonstration
Crucible with Lid High Form
Description
Chemical porcelain crucibles are glazed inside and out, except outside bottom and rim. Crucible covers are completely glazed except for rim. For use in temperatures up to 1150 C (2102 F). Not recommended for minerals or metals.Capacity :
100mlHeight :
2.13 inch (54mm)Top Outside Diameter :
2.56 inch (65mm)Botany Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting, with plastic rollers, size 75 x 100 cm. T.S. in Dicot & Monocot stem Pinus-1 Male & Female Strobli L.S. Shoot Apex & it’s different regions T.S. Shoot Apex & it’s different regions Plant Tissue Cork L.S. in Flower with T.S. in Anther Plant tissue Xylem T.S. in simple Pit Pinus II through female Strobilus L.S. through ovules Plant tissue Collenchyma Marchantia Life Cycle Plant Tissue Parenchyma L.S. in Root Tip & T.S. in its different regions Marchantia T.S. of Root (Secondary Growth) Adiantum Life Cycle Stages of formation of Female Gametophyte with the process of Pollination, Fertilisation & Formation of seed Plant Tissue Phloem Plant Tissue Sclerenchyma T.S. in Stem to show growth with a drawing of Lenticel Adiantum T.S. Dicot & Monocot Root Typical plant cell, English only Plant Mitosis English only Plant Meiosis, English only Classification of Plants, English onlyXTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Rheostat, Single Tube
Description
A layer of oxidized resistance wire is wound on a porcelain tube which is supported by end supports. A sliding contact and three 4 mm socket terminals are provided for use as a rheostat or as a potentiometer. Other ranges also available on request.Ohms | Ampere | Tube length | |
---|---|---|---|
23 | 2.3 | 150mm | |
10 | 3.3 | 150mm | |
22 | 2.8 | 200mm | |
24 | 3.3 | 250mm | |
28 | 4.2 | 400mm |
HVDC Transmission Line Simulator
The HVDC Transmission due to its advantages, like long distance transmission, interconnect different power systems (like 50Hz and 60Hz), more energy transmits than AC, less losses, make it essential for the students to study & understand the operation of HVDC. Vi Micro have introduced a trainer for this purpose “HVDC Transmission Line Simulator”
HVDC Transmission Line System consists of
• Generating Station Module • Rectifier Station Module (SCR or IGBT Based) • Simulated HVDC Transmission Line Module • Inverter Station Module • Loading ModuleGenerating Station Module
• It consists of a 3Φ, 415V Variable AC source, 1.5 KVA step up transformer, a Multifunction Meter (To measure various electrical parameters of • Generating side or sending end) & a Miniature Circuit Breaker. • Earth Fault Relay is provided for protection against Earth Fault. • The module is covered with metallic enclosure and sticker represents the prime operation of the module. Safety power plug-sockets are provided.Rectifier Station
• Two no’s of fully controlled SCR based bridge rectifiers provided to convert 3Φ AC to DC for HVDC transmission. • Two 6 Pulse SCR bridges connected in series • Can be configured as 12 Pulse Rectifier • A 3Φ, 1.5KVA transformer with (Y) primary and dual (Δ, Y) secondary are provided to reduce harmonics • The module is covered with metallic enclosure and sticker represents the prime operation of the module.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Hydraulic Linear Actuation System Trainer with Labview Interfacing
Features
• This trainer helps to learn the characteristics of double acting cylinder namely direction, speed & force. • A Microcontroller ADC relay driver provided to actuate the cylinder. • Gear pump supplies the hydraulic fluid to double acting cylinder through direction control valve. • Pressure control valve controls the flow rate of fluid to cylinder. • Single phase induction motor drives the pump. • Control unit communicate with PC and controls the double acting cylinder using LabVIEWSoftwares. • Two proximity sensors are provided to indicate the position of the cylinder. • Load cell measures the force developed by the cylinder. • 5/2 Double Solenoid Valve directs the cylinder. • One tank is used to store the hydraulic fluid.Abney Level Made of Brass pipe
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Matt White Screen
Multi Stage Centrifugal Pump Test Setup
DESCRIPTION:
The Set-up is designed to study the performance of Multi Stage Centrifugal Pump. The Set-up consists of a Multi Stage Centrifugal Pump coupled with DC motor & drive, supply tank, measuring tank & pipe fittings for closed loop water circulation. There are 2 separate pumps connected to DC Motor and drive and can be connected in series and parallel to stimulate different combinations. Pressure and Vacuum Gauge are connected on delivery and suction side of each pump for the purpose of measurement. Swinging Field Dynamometer arrangement for direct torque measurement using dial type spring balance is made for individual pump. The flow rate of water is measured using measuring tank and stop watch provided.EXPERIMENTS:
1.Speed Vs Discharge 2.Head Vs Discharge at various speeds 3.Efficiency curves at various speed and headsFEATURES:
1.Closed loop water circulation 2.Compact & stand alone set-up 3.MS Excel sample calculation program on demand 4.Stainless Steel tanks and wetted parts 5.Superb painted structure 6.Simple to Operate & MaintainUTILITIES REQUIRED:
1.Electric Supply: – Provide 230 +/- 10 VAC, 50 Hz, Single Phase Electric Supply with proper earthing. (Neutral – Earth voltage less than 5 VAC), 5 A, three pin socket with switch for pump. 2.Water Supply: Tap water connection ½” BSP. Distilled water @ 80 Ltrs. (Optional extra cost)TECHNICAL SPECIFICATIONS:
1.Pump (2 Nos.) : Kirloskar, Capacity 1 HP Speed 2800 RPM (max.) Head 12 m (max.) 2.Drive : DC Drive along with non-contact type Digital RPM Indicator 3.Supply Tank : Capacity 150 Ltrs. 4.Measuring Tank : Capacity 100 Ltrs. fitted with Piezometer Tube & Scale 5.Piping : GI / PVC 6.Stop Watch : Electronic 7.Control Panel : With required electrical instrumentation The whole Set-up is well designed and arranged in a good quality painted structure.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT