XTEMOS ELEMENT

AJAX PRODUCTS TABS

Featured
  • Featured
  • Accessories
  • Furniture

Digital Coating Thickness Meter

Description

Digital Coating Thickness Meter We offer high quality of Digital Coating Thickness Gauge. Statistics (Number of readings, average, Std. deviation, max. ,; min.) are updated with every reading and displayed simultaneously. It helps to decide how many readings are to be taken. Continue taking readings till you start getting reasonably consistent statistics.

Metal Rivets, Brass

Description

Supplied as rivets. Pk of 500gms. Brass,lead,aluminium,iron, For specific heat capacity experiments. Supplied as rivets. Packets of 500 grams.300 mm long x 3 mm dia. Supplied in packets of ten rods. Copper,iron,lead,aluminium,brass 300 mm long x 3 mm dia. Supplied in packets of ten rods.

2 Stroke 1 Cylinder Petrol Engine Manual Driven

The engine will be sectioned to show the internal constructional details. The working of individual part and accessories like Valves, Pistons, pumps, Crank and Camshaft, etc. will be demonstrated. It is provided with Flywheel and it is mounted on a sturdy iron frame. This actual cut section engine helps the student to understand about the parts and the working of the engine very easily. It is specially made dissectible for demonstration purposes. The actual cut section engine will be supplied with key card & very interesting literature regarding working.
XTEMOS ELEMENT

AJAX PRODUCTS TABS SIMPLE

shirt-tab
Fashion
Featured
  • Featured
  • Man
  • Woman

Thermal Conductivity Of Liquid

Thermal conductivity of is an important engineering property. The apparatus uses guarded hot plate method for determining thermal conductivity. It consists of hot plate i.e. an electrical heater sandwiched between two plates. The heat loss from hot plate is prevented by using two guard heaters and heat of removes heat from liquid by circulation of water. Input to heaters the temperatures.

SPECIFICATIONS:

1.Guarded hot plate assembly comprising of main heater, ring guard heater and top guard heater, mounted over the liquid test cavity. 2.Cold plate assembly provided with water connections. 3.The assembly is housed in an enclosure box with glass wool insulation. 4.Instruments panel consisting of : a).Digital voltmeter and ammeter of suitable range. b).Dimmerstat for controlling input to the heaters (2 amp. 3 Nos.) c).Multichannel digital temperature indicator.

SERVICES REQUIRED:

1.Floor space of about 0.75m. x 1.5m. at working height. 2.230v. AC electrical supply with earthling connection. 3.Water flow rate of about 10- 15 lit/min. at constant head.

Digit Counter Micrometer (DCM)

Description

Micrometer is used to measure short lengths accurately Technical Details : Printed Marking on the Vernier Scale Carbide Tipped Measuring Faces Blue Metallic Finish Frame With Locking Clamp and ratchet stop Least Count : 0.01mm With Digit Counter to withstand abuse at work Sizes : 0-2 25-5 50-7 75-100 Specifications: Guarantee ; 6 Months without abuse Packing ; Plastic Box Calibration ; In house.

Android Based WSN Evaluation Kit

We are pleased to introduce a trainer which offers all the components (ARM 11 processor Board + GSM module + CMOS Camera + GPS module + ZigBee module +SD Wi-Fi module) of a Smart Cell Phone which works on Android OS which also Occupies 50% of the smart cell phone market. This Development Board gives you an Comprehensive solution integrating both hardware and software. These features make it easily and widely used in MID development, auto electronic devices, industrial applications, GPS systems and multimedia systems. It is good for educational training, embedded development and DIY as well.

Features

• ARM11 Samsung S3C6410, ARM1176JZF-S, up to 667MHz • 256MByte mDDR RAM and 1GByte NAND Flash • 1 x 4-wire resistor touch screen interface, • 1 x 100M Ethernet interface, • 1 x DB9 5-wire serial port • 1 x Mini USB 2.0-OTG interface and USB Host 1.1 interface, • 1 x 3.5mm audio output and on board microphone interface, • 1 x TV-OUT • 1 x SD card socket, • 1 x Infrared receiver, • 4 x TTL serial port, • 1 x CMOS camera interface, • 1 x SDIO2 interface (can be connected to SD WiFi module), • 1 x 10pin JTAG interface, • 1 x PWM buzzer, • 1 x I2C-EEPROM, • 1 x backup battery for RTC, • 1 x AD adjustable resistor, • 8 x User button and 4 x LED

Model AC DC Generator

Description

Generates both AC and DC. When the two brushes of the generator are put in the two ends of the commutator, the output is an AC. When the brushes are put in the middle of the commutator, the output is a DC. Includes Instructions.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ALTERNATIVE

Fashion
Featured
  • Featured
  • Man
  • Woman

Unsymmetrical Bending Apparatus

DESCRIPTION:

Apparatus consist of an angle of size 1” x 1” x 1/8” or in equivalent metric units of length 80cm is tied as a cantilever beam. The beam is fixed at one end such that the rotation of 450 intervals can be given and clamped such that the principal axis of its cross-section may be inclined at any angle with the horizontal and vertical planes. Also arrangement is provided to apply vertical load at the free end of the cantilever and to measure horizontal and vertical deflection of the free end. A dial gauge with magnetic base is supplied with the apparatus.

EXPERIMENT MANUAL:

• To study the behavior of a cantilever beam under symmetrical and unsymmetrical bending. • Using a Dial gauge shown a increasing and decreasing of heights.

Magnetic Field Apparatus

Description

A wooden table supports a plastic ring wound with three coils of 5, 10 and 20 turns of insulated copper wire, connected to terminals on the base.

Automatic Gear Box Actual Cut Section

Automatic Gear Box – Actual Cut Section The working of automatic gear box is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of automatic gear box are shown in actual working form. This model helps the student to understand the working of the automatic gear box very easily. It is specially made dissectible for demonstration purposes.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ARROWS PAGINATION

shirt-tab
Electronics
Featured
  • Featured
  • Mobile
  • Smartwatches

Cell & Tissues

Description

All Charts are made on PVC rexine , hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall. Size 75×100 cm.

Typical Animal cell ultra structure

Animal Mitosis Animal Meiosis Animal Tissues I – Connected tissues Animal Tissues II – Epithelial and muscular tissues Animal Tissues III – Blood and nerve tissues Gamatogenesis Fertilization in Animals Ogenesis Spermatogenisis

Junior Medical Microscope

Specification

Two achromatic par focal objectives 10x &40x (SL). Wide fiels eyepiece 10x and Huygenian eyepiece 15x. Fine focusing by screw lever mechanism having a graduated knob with sensitivity 0.002mm. Fixed square stage 120x120mm with newly developed spring stage clips. Special silicon rubber feet prevents scratched and provide positive grip for life long. Rack and pinion coarse adjustment. Double lens Abbe condenser , N.A 1.25 with iris diaphragm can be moved up and down by knob on lower left side. Plano concave mirror illuminator. Magnification 100x to 600x. LED microscope lamp.

Water Cooling Tower Apparatus

The apparatus consists of a forced draught, counter flow type-cooling tower. A blower supplies cooling air. Air enters the tower at the bottom. Hot water is, obtained from a geyser. Hot water is sprayed over the mesh packing through the nozzles and it flows downwards. Evaporative cooling of water occurs due to the current of air and water gets cooled. This student can study the operation of cooling tower and calculate the energy balance.

SPECIFICATION:

Cooling tower, fabricated of M.S. Sheets, 200 X 200 mm. cross section, 1.2m. height with Perspex front. Wire mesh packing is provided in the tower. Geyser – 3 Kw Capacity to provided hot water. Centrifugal blower, 1 HP capacity to force air through the tower. Multichannel Digital Temperature indicator to measure temperature at various points. Rotameter to measure inlet water flow. Measuring tank to measure outlet water flow. Calibrated orifice and water manometer to measure airflow. Arrangement to measure dry and wet bulb temperatures of air at 5 intermediate stations. A technical manual accompanies the unit. The unit Is provided with anticorrosion an attractive color powder coating.

SERVICES REQUIRED:

440V, 32A, AC supply with neutral and earthing connection. Floor space of about 2m. X 1.5m. Water flow of 10 Ht./min. at constant head

Endocrine Glands

Pituitary Gland TS Thyroid Gland TS Parathyroid Gland TS Pancreas TS Thymus Gland TS Ovary TS Testis TS Pineal Gland TS
XTEMOS ELEMENT

AJAX PRODUCTS TABS WITH ICONS

Furniture
  • Furniture
  • Lighting
  • Accessories
  • Clocks
  • Cooking

Dissecting Dishes, Aluminium

Made from aluminium sheet. Rectangular, with flanged edges. Sizes available are (Bottom - Length x Width x Depth) Without Wax With Wax Dissecting Dishes, Stainless Steel are also Available

Laboratory Spatula

Acquire from us high quality Laboratory Spatula at affordable price range. Moulded in Polypropylene, Spatula consists of a spoon on one side while the other end is a flat construction with a knife edge. This is helpful in breaking up crystals of different salts while the spoon is used to draw salts from the containers.
ParticularsPack (Pcs) 
Spatula 150 mm12 
Spatula 200 mm12 

Emitting Diode (LED’s)

Bridge rectifier is designed with four LED’s internally arranged in bridge pattern fitted inside a plastic moulded case. Two LED’s are red and two LED’s are green. This device is used to demonstrate the functioning of a bridge rectifier, i.e., to convert alternating current (AC) into direct current (DC). Two yellow sockets are used for AC input. Two sockets, one red and one black, are used for DC output. For the easy understanding of the internal circuitry, the circuit diagram is printed on the box.
XTEMOS ELEMENT

AJAX PRODUCTS TABS LOAD MORE PAGINATION

Featured
  • Featured
  • Lighting
  • Accessories

SILICA CRUCIBLE WITHOUT LID

PRODUCT DESCRIPTION
  • Crucible is glazed inside and outside.
  • Highly resistant to alkalis and hot temperatures
  • 50ml capacity
  • Outside diameter 55mm, 42mm height
  • No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML

SILICA CRUCIBLE TALL FORM Without Lid, Translucent

PRODUCT DESCRIPTION -Without lid, translucent, glazed - Ordinary type lids to be purchased separately Size/ dimension:
  • 20ml,  Dia. 35mm x Ht. 38mm
  • 30ml, Dia. 43mm x Ht. 38mm
  • 50ml, Dia. 51mm x Ht. 51mm

SILICA MUFFLE TRAYS (For VM Crucible)

PRODUCT DESCRIPTION:   Available in 2types:  Two Hole, 39mm Length Four Hole, 76mm Length
XTEMOS ELEMENT

AJAX PRODUCTS TABS CAROUSEL

Featured
  • Featured
  • Cooking
  • Furniture