XTEMOS ELEMENT
AJAX PRODUCTS TABS
Resistance Substitution Board
Balance Weights
Polished brass, supplied with wooden block, as illustrated.
• Capacity 500 gm. Comprising 1x200 gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5 gm, 2x2 gm, 1x1 gm
• Capacity 1000 gm. Comprising 1x500 gm, 1x200 gm, 2x100 gm, 1x50 gm, 1x20 gm, 2x10 gm, 1x5 gm, 2x2 gm, 1x1 gm.
• Capacity 2000 gm. Comprising 1x1000 gm, 1x500gm, 1x200gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5gm, 2x2gm, 2x2gm, 1x1gm.
Journal Bearing Apparatus
DESCRIPTION:
The apparatus consists of a plain steel shaft encased in a bearing and directly driven by a small electric motor. The bearing is freely supported on the shaft and sealed at motor end. The motor speed is precisely controlled by control unit and sealed at motor end. The motor speed is precisely controlled by control unit and can be run in both directions. The bearing contains twelve equi-spaced pressures tapping around circumference and four along the axis. All are connected by light flexible plastic tube to the manometer so that the pressure head of all sixteen point can be observed at a time. The bearing can be loaded by attaching weight to the arm supported beneath it.SPECIFICATIONS:
1. Journal : 50 mm. dia. (nominal) 2. Bearing : 55 mm. dia. 3. Weights : 4 adjustable weights 4. Motor : D.C. shunt Motor, 3,000 RPM. 5. Control panel : For speed control of Motor 6. Manometer panel : 16 tube Manometer 7. Oil recommended : SAE 10EXPERIMENTS:
1. Observation of the pressure profile at various conditions of load and speed. 2. Plotting the Cartesian and polar pressure curves. 3. Plotting the theoretical Summerfield curves.SERVICE REQUIRED:
1. Electric Connections : A.C Single Phase, 230v. supply with ear thing. 2. Stand Alone Space : 1.5m X 1.5m X 4m Height.Steam Power Plant Trainer
Introduction:
Steam Power Plant Working Unit – This Unit Helps The Students To Understand The Complete System Of A Thermal Power Plat. 1.Heat Energy Converts Water Into Steam 2.Steam Pressure When Moves A Engine Or Turbine Produces Mechanical Energy 3.Finally Mechanical Energy Is Converted Into Electricity Through AlternatorParts Details Of Boiler:
1.Boiler — For The Generation Of Steam We Have Provided Electrically Heated Boiler. 2.Diameter Of Boiler – 400 mm 3.Length Of Boiler – 600 mm 4.Heater 2 Pcs. – 3 KW (Each)XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Frequency Shift Keying Modulation And Demodulation
This Instrument is design to demonstrate the method to transmit signals via. Electromagnetic transmission and to study the Frequency Shift Keying Modulation and Demodulation. Whole instrument is placed in plastic moulded box and 2 mm banana plug leads are provided for modulation and demodulation connections.
Screw Gauge Micrometers
Cryo Rack
Our Cryo Rack is moulded in polycarbonate making it tough, durable & autoclavable.
This handy Cryo Rack can hold 50 vials can be unscrewed without actually picking them up as the vial will lock in every well and hence will not twist.
This rack is provided with four anti skid rubbers & each well is identified with an alpha-numeric index.
Material : Polycarbonate
Particulars | Pack (Pcs) | |
---|---|---|
Cryo Rack | 2 |
Wide Mouth Reagent Bottle
Our Wide Mouth Reagent Bottle is available in Polypropylene.
The PP Wide Mouth Reagent Bottle, offered by us, are largely demanded for their unique features.
These features include Rigid, Translucent and have Excellent Contact Clarity.
Moreover, our Wide Mouth Reagent Bottle is available at affordable prices.
Particulars | Pack (Pcs) | |
---|---|---|
Reagent Bottle (Wide Mouth) 30 ml | 12 | |
Reagent Bottle (Wide Mouth) 60 ml | 12 | |
Reagent Bottle (Wide Mouth) 125 ml | 12 | |
Reagent Bottle (Wide Mouth) 250 ml | 12 | |
Reagent Bottle (Wide Mouth) 500 ml | 12 | |
Reagent Bottle (Wide Mouth) 1000 ml | 6 | |
Narrow Mouth Bottle 4000 ml | 1 | |
Wide Mouth Square Bottle 4000 ml | 1 | |
Heavy Duty Vaccum Bottle 2000 ml | 1 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
VM CRUCIBLE with Lid 25mm Dia x 38mm ht.
Theramal Conductivity Of Insulating Slabs
The apparatus consists of a slab assembly. The main Heater and a radial guard heater are sandwiched between copper plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other Sides of the specimen. The radial guard heater ensures all heat of the main heater to pass axially through the specimens which is collected by cooling plates. By knowing the temperatures and Heat input, thermal conductivity of specimen can be calculated. The test set up is enclosed in an enclosure with insulation inside to provide undisturbed Surroundings. The design style of the apparatus is similar to as recommended in INDIAN standard. The difference is in sizes.
SPECIFICATIONS:
1.Heaters: a)Main heater plate 110 mm dia. with mica heater Sandwiched between copper plates. b)Radial guard heater plate I.D. 120mm and OD 200 mm mica heater sandwiched between copper plates. 2.Water circulated cooling plates -2 nos. 3.Dimmerstat-2 A capacity – 2 nos. to independently control Inputs to the heaters. 4.Measurements – A voltmeter and an Ammeter with selector switches to measure inputs,Multichannel digital temperature indicator to measure Temperatures at various points, having 0.1 °c least count. A technical manual accompanies the unit.SERVICES REQUIRED:
1.230 V, A.C. stabilized supply along with earthing connection. 2.Water supply of about 4-5 lit/min. 3.Bench area 1m x lm x O.5m height.Genetics
Description
All Charts are made on PVC rexine, hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall, Size 75×100 cm. Monohybrid Crossing complete dominance Monohybrid Crossing incomplete dominance Dihybrid Crossing Monohybrid Crossing Mendelian explanation of Cross between tall & dwarf races in Garden Pea Sex linked inheritance Drosophila Mendelian Heridity of Blue & Adulsian fowls Mendelian Explanation of the breeding behaviour of Red & White flowering in 4 o’clockMetabolic Cage for Rat
Description
Animal waste is directed through a collection funnel and onto a linear diffuser guide. The diffuser guide allows solid matter to travel down the top ridges of a 50% incline, passing over a urine port, and into a fecal collection vessel. Liquid waste flows along grooves down the inclined diffuser guide, passing through the urine port, and into a urine collection vessel. A urine deflector prevents excess urine from splashing and contaminating fecal specimen. Separate urine and feces samples are collected in two separate tubes.Features
Reliable experiment results due to better separation efficiency Food hopper design reducing the access or stay of animal inside food hopper Practicality of use due to less components or partsMinimal animal stress: | Sample removing is without stressing animal, access to all elements below the cage floor without disturbing animal |
Durability: | Most components are made from autoclavable polycarbonate and S.S. 304 material |
Versatility: | Unit accommodates various species with simple feeder and floor change Space saving |
Economy: Few parts, simple and rapid assembling |
Components Included
Polycarbonate cage with lid
Polycarbonate collection funnel
S.S. 304 floor grill for Mice and Rat
Polycarbonate Linear diffuser guide
Urine collection tube P.P.
Feces collection tube P.P.
Polycarbonate water bottle 250ml with holder
Waste water collection tube P.P.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Malu’s Law
Description
Students can investigate the relationship between the intensity of transmitted light and the angle of rotation of two polarizing filters. A graduated cartridge containing two polarizing filters allows students to observe the change in intensity as they are rotated relative to one another. The analyzer allows quantitative readings to be taken using a voltmeter at five degree intervals as the polarizing filters are rotated from minimum to maximum transmission. The output from the analyzer changes linearly with light intensity and so the resulting data can be used to verify Malus Law. Includes instructions.Porcelain Desiccator Plates
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Induction Coil
Description
This box form Induction Coil has a 50 mm spark gap and can produce pulses of high voltage spark from a low voltage direct current source such as a battery. It is suitable for use with gas-filled discharge tubes, vacuum tubes, eudiometers and for general laboratory work. It is comprised of two coils fully enclosed in a polished wooden case with binding posts. Spark gap at the discharge points can be adjusted by sliding rods back and forthHuman Physiology Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting with plastic rollers, size 75 x 100 cm. Skeletal System Muscular system Circulatory system Nervous system Digestive system Teeth & skin Human eye, ear & head Lymphatic system Respiratory system Endocrine system Nutrition Immune system Human Nose Human Heart Excretory system Human Eye Human Ear Human Kidney Human Lungs Human LiverFriction Board
Distributed Control System
A powerful, modular & upgradable DCS has been designed and configured based on Siemens controller SIMATIC PCS7 ASRTX (Micro Box). Distributed I/O system ET200M can be provided for field automation. The distributed I/O can be connected via Profibus, Communication. DCS consists of controller, Power supply unit, distributed I/O, Digital Input and Output modules, Analog Input and Output module. a Demo Panel and Simatic PCS7 V9.0 Software.
DCS Controller
• Make : SIEMENS. • Controller : SIMATIC PCS 7 AS RTX BOX. • Profibus Communication done via CP5611 onboard. • Transmission Rate of Profibus cable is 12 Mbit/s. • 2 x GBIT & RJ45 LAN • Core 17-3517 Processor 1.7GHz, 4GB DDR3 RAM, SSD 80GB, 4xUSB V3.0 • Mouse and Keyboard • Windows7 • Win AC RTX 2010 software controllerDistributed I/O station ET200M
• Support HART, PROFIBUS, Foundation Field bus. • 16 No’s of digital Inputs with 24V DC. • 16 No’s of digital Outputs with 24V DC. • 8 channels of Analog Inputs with 4-20mA. • 8 channels of Analog Outputs with 4-20mA. • 24VDC /10A inbuilt power supply.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT