XTEMOS ELEMENT
AJAX PRODUCTS TABS
Resistance Coils
Insect Collecting Net’ Executive’ (Telescopic)
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Worm Sector Type Steering System
Worm & Sector Type Steering System – Actual Working
The working of steering system is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of steering system are shown in actual working form. This model helps the student to understand the working of the steering system very easily. It is specially made dissectible for demonstration purposes.
Brown Plant Hopper Insect Rearing Cage
Description
Framework of seasoned teakwood, nicely polished. Front door and top provided with non rattling glass and back & two sides with nylon wire screen supported by fine wire mesh. Wooden base covered with laminated sheet from inside. Size: 45x45x55 cm. Brown Plant Hopper Insect Rearing Cage Size: 60x60x80 cm.Electro Mechanical Type Over Voltage Relay Study Trainer
This test set-up consists of a. Electromechanical over voltage-relay. b. Relay test setup with meter.
Electromechanical over voltage-relay
• One electromechanical type over voltage relay - Make: Megawin - Voltage setting multiplier (121V, 132, 143, 154, 165, 176, 187V) - Time setting multiplier. - One “NO” contact @ 220V, 10Amp rating. - One “NC” contact @ 220V, 10Amp rating. b. Relay test setup with meter • One 0-300V, 1AMP variable AC source provided for relay coil. • One auto transformer provided for AC voltage adjustment. • One illuminated rocker switch provided for power ON/OFF. • One digital voltmeter used to indicate applied voltage. • One digital timer provided for relay tripping time measurement. • One automatic relay tripping time measurement circuit. • One start/stop push-to on switch provided for time measurement circuit. • One reset switch provided for timer reset.Signal Generator
1 Hz to 100 KHz in five decade ranges selected by rotary switch named as frequency Multiplier. Sine Triangular and Square waveforms selected by push switch with LED indication. Output signal is 0-3.5 V rms (10 V peak to peak) open circuit continuously control with uncalibrated amplitude control knob. Mains rocker switch with indicator Light. Signal Generator is versatile for general laboratory use; output signal is adjustable with the combination of Freq. multiplier and set frequency dial with a low level of distortion. Output Voltage is continuously variable with selector range 1V and 10V. There is two pair of output safety sockets. One for CRO output (experiment for amplification, filter etc.) and another pair of sockets to speaker to drive a speaker and to demonstrate the audio signal frequency range 20 Hz to 20 KHz.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Evolution
Recalculating Ball Type Steering System
Recalculating Ball Type Steering System – Actual Working
The working of steering system is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of steering system are shown in actual working form. This model helps the student to understand the working of the steering system very easily. It is specially made dissectible for demonstration purposes.
Constant Volume Air Thermometer
Description
A metal stand fitted with 0-100 cm x 1 mm vertical wooden scale and supporting a mercury reservoir sliding on a metal rod. An air thermometer bulb fitted to a bracket can be attached to the other rod at either of two positions. With U-shaped base. Complete with 1 meter rubber tubing to connect reservoir to the bulb. Supplied without mercury.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Hydraulic Drum Brake Actual Working Single Drum
Electro Mechanical Type Over Voltage Relay Study Trainer
This test set-up consists of a. Electromechanical over voltage-relay. b. Relay test setup with meter.
Electromechanical over voltage-relay
• One electromechanical type over voltage relay - Make: Megawin - Voltage setting multiplier (121V, 132, 143, 154, 165, 176, 187V) - Time setting multiplier. - One “NO” contact @ 220V, 10Amp rating. - One “NC” contact @ 220V, 10Amp rating. b. Relay test setup with meter • One 0-300V, 1AMP variable AC source provided for relay coil. • One auto transformer provided for AC voltage adjustment. • One illuminated rocker switch provided for power ON/OFF. • One digital voltmeter used to indicate applied voltage. • One digital timer provided for relay tripping time measurement. • One automatic relay tripping time measurement circuit. • One start/stop push-to on switch provided for time measurement circuit. • One reset switch provided for timer reset.Tubing, Rubber
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Leopold Maneuvers Simulator
Description
One piece fetal baby with palpable fontanelles, spine, shoulders, elbows, and knees Fetal baby may be placed in normal, breech, or transverse position Fetal baby cradled between two “cushions” Cushions may be inflated independently of the other; inflation of the lower cushion raises the fetus to desired position; inflation of the upper cushion creates a firm abdomen as in the ninth month of pregnancy The Palpation Module is designed to be used with the Advanced Childbirth Simulator.Pulleys
Buchner Funnel
Description
Adarsh is engaged in exporting different types of Porcelain Funnels. We are the foremost Exporter, and Supplier of Buchner Funnel (with Thin as well as Thick Stem) and Hirsch Funnel. All the varieties of our Porcelain Funnels are praised for their matchless quality and reasonable pricing.Diameter Sizes
1. Dia 2" 2. Dia 2.5" 3. Dia 3" 4. Dia 4" 5. Dia 5" 6. Dia 6" 7. Dia 8" 8. Dia 10"Burettes with Rota Flow Stopcock (BG)
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT