XTEMOS ELEMENT
AJAX PRODUCTS TABS
Aluminum Calorimeter, with wooden box
Episiotomy Training Simulator
Description
Suturing Simulators provide a realistic way for students to learn good surgical techniques. The simulators provide students with a variety of repair experiences without the constraint of time and concern for safety, which are factors with a live patient. The simulators can be used by the student in a learning lab with an instructor or by the student individually in the clinical setting just prior to a patient experience. They are also useful as homework teaching aids that can be signed out at night and returned the next day. In addition to being portable, the lifelike texture allows the learner to develop a “feel” for instrument handling, tension on suture, and the advantages of one method of tying knots over another.Includes one of each simulator:
Midline Suture Simulator Left Mediolateral Suture Simulator Right Mediolateral Suture Simulator Each simulator comes with an instruction booklet and is individually boxed.Thermal Conductivity Of Liquid
Thermal conductivity of is an important engineering property. The apparatus uses guarded hot plate method for determining thermal conductivity. It consists of hot plate i.e. an electrical heater sandwiched between two plates. The heat loss from hot plate is prevented by using two guard heaters and heat of removes heat from liquid by circulation of water. Input to heaters the temperatures.
SPECIFICATIONS:
1.Guarded hot plate assembly comprising of main heater, ring guard heater and top guard heater, mounted over the liquid test cavity. 2.Cold plate assembly provided with water connections. 3.The assembly is housed in an enclosure box with glass wool insulation. 4.Instruments panel consisting of : a).Digital voltmeter and ammeter of suitable range. b).Dimmerstat for controlling input to the heaters (2 amp. 3 Nos.) c).Multichannel digital temperature indicator.SERVICES REQUIRED:
1.Floor space of about 0.75m. x 1.5m. at working height. 2.230v. AC electrical supply with earthling connection. 3.Water flow rate of about 10- 15 lit/min. at constant head.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Brush, Semi Micro
Magnifier, Reading Glass
2 Stroke 1 Cylinder Petrol Engine Manual Driven
The engine will be sectioned to show the internal constructional details. The working of individual part and accessories like Valves, Pistons, pumps, Crank and Camshaft, etc. will be demonstrated. It is provided with Flywheel and it is mounted on a sturdy iron frame. This actual cut section engine helps the student to understand about the parts and the working of the engine very easily. It is specially made dissectible for demonstration purposes. The actual cut section engine will be supplied with key card & very interesting literature regarding working.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Centrifugal Blower Test Rig
The apparatus consists of a spiral casing, which houses an impeller. Impeller is driven by a variable speed D.C. motor. Three, interchangeable impellers, viz. Radial forward and Backward curved vanes are provided with the unit. Digital indicators are provided for speed of impeller. A venture provided measures the discharge. Thus students can evaluate the performance of different impellers at various speeds.
SPECIFICATIONS:
1.Blower – Spiral casing with three interchangeable impellers viz. forward, backward and radial vanes. 2.Drive Motor-1 HP DC motor, 3000 RPM with Dimmer control to vary the speed from 300 to 3000 RPM. 3.Digital Speed indicator for speed measurement. 4.Ventura with water manometer to measure air flow. 5.Water manometer to measure discharge pressure. 6.Discharge pipe with flow control valve. 7.A technical manual accompanies the unit.SERVICES REQUIRED:
1.Floor space of about 2m X 1.5m X 1.5m height. 2.230 V. 5A., 50 Hz, AC Supply.Electrophoresis Horizontal
Description
With rich industry experience and support of highly skilled quality experts our organization is engaged in providing a wide range of Electrophoresis Horizontal Mini-GEL that is commonly used for carrying out number of analytical tests by separating DNA and RNA on the basis of shape, size, and electrical affinity. It is offered with platinum electrodes that are almost hundred percent pure. We also provide gel casting tray, one comb with a terminal lead.Features:
Easy maintenance Precision-designed Flawless functioningSpherometer
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Simple Circuits Kit
Description
To explain working of electricity by simple circuits. Students can create simple circuits and learn about electricity, currents, voltages, series circuits and much more. Kit includes: D cell battery holder, knife switch, 2 light bulb holders, 2 light bulbs, 5 alligator connector cords and instructional manual.Opthalmic Microscope
Specifications
Double focusing mechanism. Programmable multi-function footswitch. Electromagnetic locks. Suitable for all types of ophthalmic surgery. Space-saving design provides large working area. Easy illumination bulb exchange allows the spare lamp to be immediately rotated into position if the main lamp fails.Magnification | : | 4.2x –21x | |
Optics | : | Objective Lens | |
: | F=200mm | ||
Zoom | : | Continuous zoom |
Kaplan Turbine Test Setup
DESCRIPTION:
Kaplan Turbine is an axial flow reaction Turbine named in honor of Dr. B. Kaplan, a Gennan Engineer. This turbine is suitable for low head. The power produced by a turbine is proportional to QH. As the head (H) decreases the J discharge (Q) must increase to produce the same power. The present Set-up consists of a scroll casing housing a runner. Water enters the turbine through the stationary guide vanes and passes through the runner axially. The runner has a hub and airfoil vanes, which are mounted on it. The water is fed to the turbine by means of Centrifugal Pump. The runner is directly mounted on one end of a central SS shaft and other end is connected to a brake arrangement. A transparent hollow cylinder made of acrylic is fitted in between the draught tube and the casing for observation of flow on to the airfoil vanes. This runner assembly is supported by thick cast iron pedestal. Load is applied to the turbine with the help of this brake arrangement so that the efficiency of the turbine can be calculated. The Set-up is supplied with control panel. A draught tube is fitted on the Outlet of the turbine. The Set-up is complete with guide mechanism. Pressure and Vacuum Gauge are fitted at the Inlet & Outlet of the turbine to measure the total supply head on the turbine.EXPERIMENT:
1.To study the operation of a Kaplan Turbine 2.To determine the Output Power of Kaplan Turbine 3.To determine the Turbine EfficiencyUTILITIES REQUIRED:
● Water Supply and Drain.● Electricity 15 kW, 440V AC, Three Phase
TECHNICAL SPECIFICATIONS:
MODEL | HM 109 (1.33 HP) | HM 109 (5 HP) | |
Output Power | 1.33 HP / 1 Kw | 5 HP / 3.75 Kw | |
Discharge | 1500 LPM (Approx.) | 5000 LPM (Approx.) | |
Supply Head | 5 m | 5 m | |
Rope Brake Dynamometer | Dia 200 mm | Dia 300 mm | |
Sump Tank | Capacity 300 Ltrs. | Capacity 600 Ltrs. | |
Water Circulation Centrifugal Pump | Capacity 7 HP, Three Phase | Capacity 20 HP, Three Phase | |
Speed | 1500 RPM (approx.) | ||
Runner | With adjustable Curved Vanes | ||
Discharge Measurement | Pitot Tube with Manometer | ||
Control Panel | Star/Delta Starter, Mains Indicator, MCB for overload protection | ||
The whole set-up is well designed and arranged in a good quality painted structure. |
Human Ear, 6 Parts
Description
Four times enlarged, dissectible into 6 parts. Shows outer, middle and inner ear. Removable tymponic membrane with malleus and incus as well as labyrinth with stapes, cochlea and vestibulocochlear nerve (2 part) with two removable bone sections to close the middle and inner ear. On board with key card.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Slide Storage Rack
We are engaged in providing Slide Storage Rack can hold 100 slides which are recognizable through the numeric indexing.
Spacing between the slots provides adequate backward & forward movement of slides for convenient recognition.
Made of ABS, the transparent cover provides excellent view of the slides stored inside.
Material : Acrylonitrile Butadiene Styrene
Particulars | Pack (Pcs) | |
---|---|---|
Slide Storage Rack - 100 Slides | 6 | |
Float Rack | 12 |
Plain Laboratory Desiccator
We offer premium range of Plain Laboratory Desiccator which can be availed at market leading price range. Plain Desiccator have excellent quality and durability.
Grease should be applied on the flanges to make it air tight.
Material : Polypropylene/ Polycarbonate
Particulars | Pack (Pcs) | |
---|---|---|
Desiccator (Plain) PP/PC 150 mm | 1 | |
Desiccator (Plain) PP/PC 200 mm | 1 | |
Desiccator (Plain) PP/PC 250 mm | 1 | |
Desiccator (Plain) PP/PC 300 mm | 1 |
Scintillation Vial
We provide an impressive range of Scintillation Vial to our clients.
These unbreakable vials, molded in Polyethylene, are fitted with leak proof screw caps.
These Scintillation Vial can be used with standard counting equipment for liquid scintillation system.
Fabricated from high grade components, Scintillation Vial is excellent for low activity count.
Material : High Density Polyethylene
Particulars | Pack (Pcs) | |
---|---|---|
Scintillation Vail 8 ml | 100 | |
Scintillation Vail 20 ml | 100 | |
Rack For 90 Vails of 8 ml Scintillation Vail | 2 | |
Rack For 50 Vails of 20 ml Scintillation Vail | 2 |
Cam Analysis Apparatus
The apparatus is designed to study the cam profiles and performance of cam and follower system. The apparatus consists of a shaft supported by ball bearings upon which three different types of cams can be mounted.
The push rod for follower is supported vertically, which can adopt three different types of followers. Cams and followers can be changed easily. A variable speed motor rotates the cam. A dial gauge permits plotting of follower displacement with respect to cam position. By operating the system at different Speeds, jump speed can be found and also the effect of weight and spring force on jump speed can be studied. Jump can be visualized also with the help of stroboscope (it is not supplied With the product).
SPECIFICATIONS OF CAM ANALYSIS APPARATUS:
1.Cam -Eccentric, tangent and circular ARC type – one each. 2.Follower- mushroom, flat faced and roller type – one each. 3.Cams and followers are hardened to reduce wear of the surfaces. 4.Variable speed motor coupled to camshaft of suitable range and Variac. 5.A dial gauge to note the follower displacement. 6.A technical manual accompanies the equipment.SERVICES REQUIRE FOR CAM ANALYSIS APPARATUS:
1.230 V, A.C. stabilized supply along with earthing connection. 2.Bench area 0.5m x 0.5m x 0.5m height. 3.Tachometer to measure the jumping speed, (can be supplied extra)XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT