XTEMOS ELEMENT
AJAX PRODUCTS TABS
Human Tooth, Upper Triple Root In 2 Parts
Oxygen And Carbon Cycle In Nature
Brown Plant Hopper Insect Rearing Cage
Description
Framework of seasoned teakwood, nicely polished. Front door and top provided with non rattling glass and back & two sides with nylon wire screen supported by fine wire mesh. Wooden base covered with laminated sheet from inside. Size: 45x45x55 cm. Brown Plant Hopper Insect Rearing Cage Size: 60x60x80 cm.Micro Convavity Slides
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Stereo Microscope
Specifications
Objective Lens | : | 1x & 2x. | |
Eyepiece Lens | : | WF 10x/20mm (or 15x on request) (Paired) | |
Magnification | : | 10x or 20x (15x or 30x with 15x eye piece) |
Gas Turbines Or Turbojet Engine Model
Artery model showing plaque building
ZigBee Sensor Battery Board
ZigBee is one of the advanced Wireless technology and CC2530 is the Second Generation System On chip, Which has integrated Microcontroller with IEEE 802.15.4 Compliant and ZigBee RF transceiver. Vi ZigBee development Kit includes the hardware using CC 2530 and software to support the ZigBee protocol.
Features
• 2-AA battery holder integrated • 2 user LEDs • 2 user key • Light sensor • ADC Trim pot • RF Module connectivity • USB to serial connector • ADC channels are terminated via 3 pin connectors • All the IO lines are terminated via 20 pin header • 3 pin connector provision for I2C and SPI interface.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Line Shaft Unit
Description
For showing the conversion from electrical energy via mechanical, to potential energy by winding up a weight on a cord. One end of the 6mm. steel shaft carries an aluminium 'V' pulley 56 mm. diameter, and the other end is fitted with a cord anchoring collar. Supplied complete with driving belt.Rheostat
Description
These linear variable rheostats are mounted inside protective cover. The wire is wound on a ceramic tube. Three 4 mm safety socket terminals are provided for connection so the rheostat can serve as variable resistor as well as voltage divider.Resistance | Max current | |
---|---|---|
0-10Ω | 4 Amp | |
0-33Ω | 3.1 Amp | |
0-100Ω | 1.8 Amp | |
0-330Ω | 1 Amp | |
0-1000Ω | 0.57 Amp |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Storage Vial (O Ring)
Crucibles Porcelain Gooch
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Spectrometer Prism
Air Conditioning Trainer General Cycle Type
The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. cooling coil). Measurements of various parameters Torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning.
SPECIFICATIONS:
1.Cooling circuits – It consists of: a) Hermetic compressor, having the capacity of 2/3 ton of refrigeration (approx.) using R-22 refrigerant. b) Rotameter for liquid refrigerant flow measurement. c) Pressure gauges for high and low pressure. d) Prescott (i.e. high and low pressure cut-out). e) Thermometers for temperature measurement at various points In the cycle. f) Energymeter for compressor input measurement. g) Condensate measuring arrangement. 2.Heating Circuit – Air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 Kw. 3.Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. in which airflow is generated by axial flow fan. 4.Anemometer for measurement of air velocity, (range 0-15 m/sec. Following experiments can be conducted on the unit a) Cooling of atmospheric air. b) Heating of atmospheric air. c) Humidification of atmospheric air. d) Dehumidification and heating of atmospheric air. (Cooling coil acts as dehumidifier at reduced airflow.)SERVICES REQUIRED:
1.440 V, 15 A, 3 Phase supply with earthing connection. 2.Floor space area about 3 m. X 2 m.Shunt Active Filter Trainer
Specification
• FPGA Spartan 3A DSP board used for generating the PWM signals. • Three phase 3 level diode clamped inverter used as a Active filter. • SRF (or) Instantaneous PQ theory will be used to generating reference current. • PI control or fuzzy logic will be used to regulate the dc link capacitor voltage. • Reference DC link Voltage will be 250V. • Hall effect current transducers used to sense the source currents, load currents and compensation currents. • Hall effect voltage transducers used to sense the dc link voltage and source voltages. • Necessary source inductor and filter inductor provided. • Input source Line voltage -200V (Peak). • Input source Current -10A (Peak). • Power Rating -3KW. • Reactive power compensation can be provided. • 3KW linear and non-linear loads will be given. • User can modify source, filter inductance and external loads. • User can modify control algorithm. • Industrial type cabinet provided. • Before compensation source current THD will be greater than 26% • After compensation source current THD - 2.5 - 4% in 3 level inverter - 4 - 5% in 2 level inverterDirect Vision Spectroscope
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT