XTEMOS ELEMENT
AJAX PRODUCTS TABS
WOULF BOTTLE
Product description:
We have in store an exceptional assortment of Woulff Bottles for our prestigious patrons. These products are developed using optimum quality raw material that is sourced from well known vendors. The range we offer is widely demanded by firms that are based in chemical industry. Moreover, our product line are packed using tamper-proof packages to ensure their safe delivery. Clients can avail these at industry-leading rates using various simple and easy payment modes.
Sizes:
250ml
500ml
Rotary Shaker (Platform Type)
Body made out of thick mild steel finished with powder coating.
Heavy duty PMDC motors for suitable capacities are provided for long time, continuous operation.
Fixed speed and variable speed models are offered.
Platform is provided RPM range-upto 250 RPM, electronic control, 0-60 min timer.
Workable on 220 V AC 50Hz single phase.
Optional
Digital R.P.M. indicator. Digital timer (0-99 min.).Platform size in cm | Holding capacity | |
---|---|---|
45x45 mm | 25 flasks of 100 ml | |
45x45 mm | 36 flasks of 50 ml | |
45x45 mm | 16 flasks of 250 ml | |
55x55 mm | 25 flasks of 50 ml | |
65x65 mm | 36 flasks of 250 ml | |
105x105 mm | 81 flasks of 50 ml | |
105x105 mm | 64 flasks of 250 ml |
Botany Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting, with plastic rollers, size 75 x 100 cm. T.S. in Dicot & Monocot stem Pinus-1 Male & Female Strobli L.S. Shoot Apex & it’s different regions T.S. Shoot Apex & it’s different regions Plant Tissue Cork L.S. in Flower with T.S. in Anther Plant tissue Xylem T.S. in simple Pit Pinus II through female Strobilus L.S. through ovules Plant tissue Collenchyma Marchantia Life Cycle Plant Tissue Parenchyma L.S. in Root Tip & T.S. in its different regions Marchantia T.S. of Root (Secondary Growth) Adiantum Life Cycle Stages of formation of Female Gametophyte with the process of Pollination, Fertilisation & Formation of seed Plant Tissue Phloem Plant Tissue Sclerenchyma T.S. in Stem to show growth with a drawing of Lenticel Adiantum T.S. Dicot & Monocot Root Typical plant cell, English only Plant Mitosis English only Plant Meiosis, English only Classification of Plants, English onlyXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Pilot Static Tube Set Up
DESCRIPTION:-
A Pitot tube is used to measure the local velocity at a given point in the flow stress. A Pitot tube of standard design made of copper / SS is supplied and is fixed below Vernier scale. The Vernier scale is capable to measure the position of Pitot tube in transparent pipe section. The pipe has a flow control valve to regulate the flow. A U-tube manometer is provided to determine the velocity head. Present Set-up is self-contained water re-circulating unit, provided with a sump tank and a centrifugal pump etc. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To find the point velocity at the center of a tube for different flow rates of water and calibrate the Pitot tube Ø To plot velocity profile across the cross section of pipeUTILITIES: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATION: –
Ø Pitot Tube : Material Copper/SS of compatible size fitted with Vernier Scale Ø Test Section : Material Clear Acrylic, Compatible to 1” Dia. Pipe Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank, Capacity 40 Ltrs. Ø Sump Tank : Capacity 70 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted StructureHuman Ear, Enlarged, 2 Parts
Induction Coil
Description
This box form Induction Coil has a 50 mm spark gap and can produce pulses of high voltage spark from a low voltage direct current source such as a battery. It is suitable for use with gas-filled discharge tubes, vacuum tubes, eudiometers and for general laboratory work. It is comprised of two coils fully enclosed in a polished wooden case with binding posts. Spark gap at the discharge points can be adjusted by sliding rods back and forthXTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Monocot Stem T. S.
Shunt Active Filter Trainer
Specification
• FPGA Spartan 3A DSP board used for generating the PWM signals. • Three phase 3 level diode clamped inverter used as a Active filter. • SRF (or) Instantaneous PQ theory will be used to generating reference current. • PI control or fuzzy logic will be used to regulate the dc link capacitor voltage. • Reference DC link Voltage will be 250V. • Hall effect current transducers used to sense the source currents, load currents and compensation currents. • Hall effect voltage transducers used to sense the dc link voltage and source voltages. • Necessary source inductor and filter inductor provided. • Input source Line voltage -200V (Peak). • Input source Current -10A (Peak). • Power Rating -3KW. • Reactive power compensation can be provided. • 3KW linear and non-linear loads will be given. • User can modify source, filter inductance and external loads. • User can modify control algorithm. • Industrial type cabinet provided. • Before compensation source current THD will be greater than 26% • After compensation source current THD - 2.5 - 4% in 3 level inverter - 4 - 5% in 2 level inverterInternally Expanding Mechanical Drum Brake System
Optical Auto Engineers Level
Features
• Excellent shockproof function. • Exclusive closed magnetic field, magnetically-dampened compensator. • Friction-braked rotation and endless horizontal drive. • Prism for viewing circular vial. • Water, dust and dirt proof. • Comes with a years warranty. • Full back up and repair service available.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Torsion Of Rods Apparatus
INTRODUCTION:
A torsion test is quite instrumental in determining the value of modulus of rigidity of a metallic specimen. The value of modulus of rigidity can be found out thought observations made during the experiment by using the torsion equation.APPARATUS:
1. A torsion testing machine. 2. Twist meter for measuring angles of twist 3. A steel rule and Vernier Caliper or micrometerDigital Stroboscope
Description :-
Stroboscopic flashes are triggered by either the internal oscillator or by external pulses which may be connected to the two 4mm sockets mounted on the rear panel of the instrument. Example of the many applications of this unit are to be found in motion analysis multi exposures photography, examination of moving parts and measurement of rotational speed.
Specifications:-
Input Volts : 220V AC, 50 Hz
Flash Rate: 0- 9999 Flashes per minute.
Resolution : 1
Display: 7 Segment LED (4 nos.)
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Ruhmkorff Coil
Description
Ruhmkorff Coil produces pulses of high voltage spark from low voltage DC source (6 – 12 V DC). It is suitable for use with gas-filled discharge tubes, vacuum tubes, eudiometers and for general laboratory work. Includes an adjustable vibrator system, primary current polarity reversal, on-off switch, a capacitor enclosed in the box and special alloy contacts. Spark gap at the discharge points can be adjusted by sliding rods back and forth. Spark Length 15 mm.Ice Melting Kit
Description
Demonstrates the difference in thermal conductivity of two different materials. The kit consists of two identical blocks, one made of aluminum and other made of plastic. When an ice cube is placed on aluminum it turns into water in seconds, while on plastic block it melts slowly. The aluminum block has a larger heat capacity and a higher thermal conductivity while the plastic block has lower values of both parameters. With instructions.Dynamic Trolley, Wooden
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT