XTEMOS ELEMENT
AJAX PRODUCTS TABS
Spectrometer Prism
Zoology Charts
Description
Poly art Charts are multi colored, accurate in details, printed on plastic, laminated on both sides, washable, non-tearable and long lasting, with plastic rollers, size 75 x 100 cm. Epithelial tissue, simple & stratified. Connective tissues, loose. Connective tissues skeletal (Bone Cartilage). Connective tissues-Blood. Nerve Cells Types of Nerve Cells Neuroglia Type of muscular tissues Plasmodium Vivax , life cycle Amphioxus Embryological Development Sponge, External morphology with T.S. Hydra, External morphology with T.S. Obelia Life cycle & T.S. in Medus Echinococcus Life Cycle Pinworm Life cycle Earthworm, external structure with T.S. in intestine & internal anatomy Earthworm, circulatory system with reproductive system Snail-L.S. through mouth Snail-reproductive system Crayfish-T.S. in Branchial Chamber Crayfish Reproductive Male & Female Cockroach Mouth parts Cockroach, internal anatomy Starfish, water vascular system Starfish, Digestive system Amphioxus General structure Amphioxus Circulatory system Fish Circulatory system Fish Reproductive system for male & female Frog circulatory system & L.S. in Heart Frog Skeletal system & L.S. in Heart Pigeon skeletal system with fore & hind limbs Pigeon Arterial & Venous system Rabbit Arterial &Venous system with L.S. in heart Rabbit-Reproductive system Male & Female Classification of animals, English only Typical Animal cell, English onlyXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Plantation Pots
Plantation Pots, moulded in polypropylene, are available in four different sizes.
The Plantation Pots have a downward extended rim, which provide convenient lifting even if the pot is filled.
The bottom of the pot is provided with holes for drain purpose.
Material : Polypropylene
| Particulars | Pack (Pcs) | |
|---|---|---|
| Plantation Pots 100 mm | 20 | |
| Plantation Pots 150 mm | 20 | |
| Plantation Pots 200 mm | 20 | |
| Plantation Pots 250 mm | 20 |
Rock Cycle Model
Magnetising & Demagnetising coil
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Newton Meters
Brush, Pipette
Tablet Making Machine (Hand Operated)
Details
Single punch automatic compression and injection device with each revolution of the wheel drive automatic feed and remove of tablets. Built on heavy cast body with centric pressure system SS hoper provided and connected by a rubber tube easy setting for thickness and hardness of tablets with nuts and locknuts.Features
Easily rotating wheel for making tablets. Compressing lever for adjustable harness of tablets. Adjustable lower punch for adjusting the thickness. Stainless steel day and punch size 6, 9, 12 mm. Electrical model can be provided in same with ½h.p motor.XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Slip Creep Measurement Apparatus
The apparatus consists of a variable speed D.C. Motor, Driving pulley and Driven pulley of equal diameter. The pulleys are mounted on input shaft (Motor shaft) and output shaft. The driven pulley can slide on the base with bearing block to change initial tension in belt. Brake drum is mounted on output shaft helps to measure power output. The motor speed is varied by dimmerstat. A two channel RPM Indicator is provided to measure speeds of driven and driving pullies respectively.
Specifications:
1.D.C. Motor – 1 HP, 1500 RPM, variable speed. 2.Driving & Driven puilies of equal diameters. 3.Brake drum along with spring balance. 4.Fiat Belt of fixed length of following materials – (i)Fabric Belt (ii)Canvas Belt. (iii)Rubber Belt. 5.Belt tightening arrangement. 6.Speed Controller unit. 7.Two Channel digital RPM Indicator. 8.Stroboscope.Experimentation –
1. To measure co-efficient of friction between pulley material and different belt materials. 2. To measure power transmitted with varied belt tensions and plotting graph of (T1 – T2).Tension Characteristics. 3. To measure percentage slip at fixed belt tension by varying load on brake drum and plot graph of (T1-T2) Vs.percentage slip.i.e. Slip Characteristics. Finding a creep zone from graph. 4. To measure belt slip speed and observe the limiting value float at constant speed when the slip just starts.Service Required:
1.230 V.A.C. stabilized power supply 2.Space -. 1.5m x 1.5 m.Thermal Conductivity Of Liquid
Thermal conductivity of is an important engineering property. The apparatus uses guarded hot plate method for determining thermal conductivity. It consists of hot plate i.e. an electrical heater sandwiched between two plates. The heat loss from hot plate is prevented by using two guard heaters and heat of removes heat from liquid by circulation of water. Input to heaters the temperatures.
SPECIFICATIONS:
1.Guarded hot plate assembly comprising of main heater, ring guard heater and top guard heater, mounted over the liquid test cavity. 2.Cold plate assembly provided with water connections. 3.The assembly is housed in an enclosure box with glass wool insulation. 4.Instruments panel consisting of : a).Digital voltmeter and ammeter of suitable range. b).Dimmerstat for controlling input to the heaters (2 amp. 3 Nos.) c).Multichannel digital temperature indicator.SERVICES REQUIRED:
1.Floor space of about 0.75m. x 1.5m. at working height. 2.230v. AC electrical supply with earthling connection. 3.Water flow rate of about 10- 15 lit/min. at constant head.Distributed Control System
A powerful, modular & upgradable DCS has been designed and configured based on Siemens controller SIMATIC PCS7 ASRTX (Micro Box). Distributed I/O system ET200M can be provided for field automation. The distributed I/O can be connected via Profibus, Communication. DCS consists of controller, Power supply unit, distributed I/O, Digital Input and Output modules, Analog Input and Output module. a Demo Panel and Simatic PCS7 V9.0 Software.
DCS Controller
• Make : SIEMENS. • Controller : SIMATIC PCS 7 AS RTX BOX. • Profibus Communication done via CP5611 onboard. • Transmission Rate of Profibus cable is 12 Mbit/s. • 2 x GBIT & RJ45 LAN • Core 17-3517 Processor 1.7GHz, 4GB DDR3 RAM, SSD 80GB, 4xUSB V3.0 • Mouse and Keyboard • Windows7 • Win AC RTX 2010 software controllerDistributed I/O station ET200M
• Support HART, PROFIBUS, Foundation Field bus. • 16 No’s of digital Inputs with 24V DC. • 16 No’s of digital Outputs with 24V DC. • 8 channels of Analog Inputs with 4-20mA. • 8 channels of Analog Outputs with 4-20mA. • 24VDC /10A inbuilt power supply.Human Torso, With Head, Half Size
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Band Brake Working Model
Theramal Conductivity Of Insulating Slabs
The apparatus consists of a slab assembly. The main Heater and a radial guard heater are sandwiched between copper plates. The specimen in the form of slabs of equal thickness are placed on either sides of heaters and cooling plates through which water is circulated are on the other Sides of the specimen. The radial guard heater ensures all heat of the main heater to pass axially through the specimens which is collected by cooling plates. By knowing the temperatures and Heat input, thermal conductivity of specimen can be calculated. The test set up is enclosed in an enclosure with insulation inside to provide undisturbed Surroundings. The design style of the apparatus is similar to as recommended in INDIAN standard. The difference is in sizes.
SPECIFICATIONS:
1.Heaters: a)Main heater plate 110 mm dia. with mica heater Sandwiched between copper plates. b)Radial guard heater plate I.D. 120mm and OD 200 mm mica heater sandwiched between copper plates. 2.Water circulated cooling plates -2 nos. 3.Dimmerstat-2 A capacity – 2 nos. to independently control Inputs to the heaters. 4.Measurements – A voltmeter and an Ammeter with selector switches to measure inputs,Multichannel digital temperature indicator to measure Temperatures at various points, having 0.1 °c least count. A technical manual accompanies the unit.SERVICES REQUIRED:
1.230 V, A.C. stabilized supply along with earthing connection. 2.Water supply of about 4-5 lit/min. 3.Bench area 1m x lm x O.5m height.Pulse Code Modulation/Demodulation
FEATURES:
• In-built sine wave generator • Test points to study different waveforms • In-built DC Power supplyTechnical Specifications:
• Sine wave Generator : Frequency : 1 KHz, Amplitude : 0 to 3Vpp • DC Voltage : -1.5 V to +1.5V • Clock Generator : Crystal based, 4.096MHz • Data rate : 64 kbps (for 8 KHz sampling rate)128kbps (for 16 KHz sampling rate) • ADC and DAC bits : 8 • Demodulator filter type : Butterworth low pass filter • Filter type : 6th • Filter cut-off frequency : 3.4 KHz • Mic Pre-amplifier : Transistor based • Compandingrange : -80dBm to +20dbm • Switched faults : 4 • Test points : 35 • Fuse : 30V, 100mV • DC Supply : ±5V, ±12V • System Bandwidth : 3.4 KHzThree Phase Transmission Line Fault Analysis Trainer
Three phase Transmission line fault Simulation Study Module
Specification
• 3 phase power supply from 3 phase generator • To simulate 3 phase balanced system fault and unsymmetrical faults • Fault study with single line and double line in 3 phase system • Faults : - L-G-Fault - L-L-Fault - L-L-G-Fault - Single Conductor open fault - Double Conductor open fault - Fault through impedance • Theoretical calculations and verification with practical results. • The transmission lines are simulated by high frequency Inductance & resistance for short, medium and long line.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT