XTEMOS ELEMENT
AJAX PRODUCTS TABS
SCR VI Characteristics Study Trainer
Specification
• Basic VI characteristics study trainer. • Consists of one no. TYN612 SCR with heat sink. • LM723 based 20V DC power supply for gate voltage. • One no. potentiometer used to vary the gate current • 0- 30V DC variable power supply for anode, cathode voltage variation. • One no. potentiometer used to vary the Vak. • One no. high voltage fixed load resistor. • One no. toggle switch to ON/OFF gate voltage. • Two nos. DC ammeter, voltmeter/multimeter provided to measure Ig&Vak, Ia. • 230V AC input. Power ON/OFF switch. • All components are mounted on a screen printed PCB fixed on a nice wooden cabinets.PH METER
Product Description
Due to our wide expertise, we are involved in manufacturing and exporting Digital pH Meter. The leading technology we have incorporated in this equipment results in accurate measurement of pH balance. Widely demanded in pharmaceutical, chemical, and food and beverage industry, this digital pH meter is available at a competitive price for our prestigious clients. Features:- Sleek design
- Accurate results
- Digital display
- Digital PH METER
- Max Make
- E.I. Make
- PH Electrode (Glass) Routine
- PH Electrode (Gell Filled) Unbreakable
- Pen type PH METER
Embryonic Development (Period Of Gestation)
Description
A set of nine detailed models, mounted on stands, showing the following stages: An Embryo About 6 Days Old, Considerably Enlarged. Uterus With The Embryo In 1st Month Of Gestation. Uterus With The Embryo In 3rd Month Of Gestation. Uterus With Foetus In 4th Month. Uterus With Foetus, Placenta And Umbilicle Cord. Uterus With Foetus In 5th Month. Uterus With Foetus In 7th Month Of Pregnancy. Uterus With Foetus In 8th Month Of Pregnancy. Uterus With Foetus In 9th Month Of Pregnancy. Complete With Key Cards.XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Brush, Cylinder
FLASK TONG
Jet Pump Test Setup
DESCRIPTION:
The Set-up is designed to study the performance of Jet Pump. The Set-up consists of a Mono-Block Jet Pump coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop oil circulation. Pressure and Vacuum Gauges are connected on delivery and suction side of pump for the purpose of measurement. The flow rate of water is measured using measuring tank and stop watch provided.EXPERIMENT:
Ø To determine overall efficiency and pump efficiency of the Jet Pump Ø To plot Head vs. Discharge, Pump efficiency vs. DischargeFEATURES:
Ø Closed loop water circulation Ø Compact & stand alone set-up Ø MS Excel sample calculation program on demand Ø Stainless Steel tanks and wetted parts Ø Superb painted structure Ø Simple to Operate & MaintainUTILITIES REQUIRED:
1.Electric Supply: – Provide 230 +/- 10 VAC, 50 Hz, Single Phase Electric Supply with proper earthing. (Neutral – Earth voltage less than 5 VAC) 5 A, three pin socket with switch for pump. 2.Water Supply: Tap water connection ½ “BSP, Distilled water @ 90 Ltrs. (Optional)TECHNICAL SPECIFICATIONS:
Ø Product : Mono – Block Jet Pump Test Rig Ø Pump & Drive : Mono – Block Jet Pump, Size 32 mm x 25 mm x 25 mm (Suction x Pressure x Delivery), Capacity 1 HP Ø Supply Tank : Capacity 70 Ltrs. Ø Measuring Tank : Capacity 50 Ltrs fitted with Piezometer Tube & Scale Ø Medium Flow : Clear Water Ø Piping : GI / PVC Ø Stop Watch : Electronic Ø Pressure Gauge : Bourdon Type Ø Control Panel : Comprises of Energy Measurement : Energy meter Electronics, L & T make Ø MCB : For Overload Protection Standard make On/Off Switch, Main Indicator etc. Ø The whole Set-up is well designed and arranged in a good quality painted structure.Tubing, Rubber
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Soil Thermometer
Germanium Diode Unit
Dissolution Rate Test Apparatus
Description
Dissolution rate test apparatus is designed to carry out simultaneously SIX TESTS of dissolution rate of tablets & capsules as per USP standards. Dissolution Rate Test Apparatus consists of water bath made of transparent acrylic fitted with an inbuilt water circulation system. Machine has a DUAL TEMP. SENSOR system which controls both water bath temperature within +/- 0.1º C & senses the temperature of jars. The motor is digitally controlled to give speed between 20 to 160 RPM precisely within +/- 1 RPM. The micro-processor also have digital timer to control test timings from 00:01 to 99:59 (HH:MM). The machine is fitted with a LCD Display which keeps the user updated about the RPM, TIME & TEMPERATURE all the time. The unbreakable jars prevent accidents related to breakage & spilling of media in the lab. The jars have acrylic lids which allow passing of stirring shaft. The shafts are suspended from the top & are operated by the motor. Stirrer Assembly can be lifted with auto lifting mechanism for easy operations.Specifications
| Speed: | Variable from 20 to 160 with accuracy of +/- 1 RPM. | |
| Temperature | 30º C to 80º C (+/- 0.5º C) | |
| Timer | 00:01 to 99:59 Hrs. with alarm. | |
| Display | 20 x 4 LCD Display | |
| Bath | Made up of 8 mm thick clear acrylic (10mm Optional) | |
| Heater | 1000 Watts Stainless Steel | |
| Sensor | Dual Sensor System (PT-100) | |
| Auto Lifting Assembly | Available | |
| Jars | Unbreakable Ploycarbonate clear jars (6 Nos.) | |
| Power | 220 / 230V AC, 50 Hz |
Porcelain Combustion Boat
Description
We offer Porcelain Combustion Boats all around the world. These Porcelain Combustion Boats are made available in varied specifications and grades. Besides, our Unglazed Porcelain Combustion Boat is highly demanded in European, Asian and other markets for its quality and diverse laboratory applications.| Capacity (ml) | Height (mm) | Width (mm) | Length (mm) | |
|---|---|---|---|---|
| -- | 10 | 12 | 80 | |
| -- | 11 | 13 | 86 | |
| -- | 11 | 13 | 90 | |
| -- | 11 | 13 | 120 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Resistance Coils
Gear Pump Test Setup
DESCRIPTION:
The Set-up is designed to study the performance of Gear Pump. The Set-up consists of a Gear Pump having a pair of meshed gears coupled with electrical motor, supply tank, measuring tank & pipe fittings for closed loop oil circulation. Pressure and Vacuum Gauges are connected on delivery and suction side of pump for the purpose of measurement. The flow rate of water is measured using measuring tank and stop watch provided.EXPERIMENT:
Ø To determine overall efficiency and pump efficiency of the Gear Pump Ø To plot Head vs. Discharge, Pump efficiency vs. DischargeFEATURES:
Ø Closed loop water circulation Ø Compact & stand alone set-up Ø MS Excel sample calculation program on demand Ø Stainless Steel tanks and wetted parts Ø Superb painted structure Ø Simple to Operate & MaintainUTILITIES REQUIRED:
Electric Supply: – Provide 230 +/- 10 VAC, 50 Hz, Single Phase Electric Supply with proper earthing. (Neutral – Earth voltage less than 5 VAC) 5 A, three pin socket with switch for pump. Oil Supply: Oil @ 30 Ltrs. (Optional extra cost)TECHNICALS SPECIFICATIONS:
Ø Pump : Gear Pump with pair of meshed gears Capacity 1 HP,Speed 1500 RPM (max.), Head 5 Kg/cm2 (max.) Ø Drive : AC Motor with step cone pulley arrangement for 3 prefixed speed DC Motor with DC Drive along with (non-contact type Digital RPM Indicator Ø Supply Tank : Capacity 30 Ltrs. Ø Measuring Tank : Capacity 20 Ltrs. fitted with Piezometer Tube & Scale Ø Piping : GI / PVC Ø Stop Watch : Electronic Ø Control Panel : With required electrical instrumentation (The whole Set-up is well designed and arranged in a good quality painted structure.Horse shoe Magnet
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Ball & Ring with stand
Critical Heat Flux Apparatus
The apparatus demonstrates the regimes of pool boiling. The test section consists of a test wire surrounded by water of constant temperature. The surface temperature of the test wire is heated by passing current through it. Due to the temperature difference between the wire surface and surroundings, the difference regimes are observed till the burnout point.
Specifications:
1.Test wire -35 gauge or 40 gauges. Length = 10cm. 2.Nichrome heater- 1 kw capacity – 1 nos. 3.Glass trough of sufficient capacity. 4.Table light to observe the test wire. 5.Voltmeter and ammeter to measure the input to the test wire. 6.Dimmerstat to adjust the voltage. A technical manual accompanies the unit.SERVICES REQUIRED:
1.220v, ISA, stabilized single-phase supply. 2.Floor surface- 1m x 1m at working height.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















