XTEMOS ELEMENT
AJAX PRODUCTS TABS
TMS320C6747 Based DSP Trainer
KEY FEATURES:
• TMS320C674x Fixed/Floating-Point VLIW DSP Core Operating upto 300MHz • 64 General-Purpose Registers (32 Bit) • Six ALU (32-/40-Bit) Functional Units • Two Multiply Functional Units • Instruction Packing Reduces Code Size • All Instructions Conditional • Hardware Support for Modulo Loop Operation • On Chip RTCON-CHIP MEMORY:
• Two Level Cache Memory Architecture • 32K-Byte L1P Program RAM/Cache • 32K-Byte L1D Data RAM/Cache • 256K-Byte L2 Unified Mapped RAM/Cache • 128K-Byte RAM Shared MemoryON-BOARD FEATURES:
• Boot mode selection Switch • 1M x 16 Bit x 4 Bank SDRAM. • 10/100M Ethernet Interface • USB1.0 & USB 2.0 Interface. • Embedded JTAG for Emulation. • 8 LED & 8 Switch for user Interface. • Expansion Connector For GPIO & Peripheral Interface. • VSDA Expansion Card for 4 Channels ADC & 4 Channels DAC. • Provision to connect external JTAG Emulator • RS232 Serial Port InterfaceDecade Inductance Box – 3 Dial
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Half lower Jaw
Bell Jar and Vacuum Pump Set
Description :- Simple, innovative kit allows you to perform a number of experiments on vacuum and air pressure.
The kit clearly demonstrates the method by which a pump works.
Also illustrates that air has mass and helps find its mass and density.
Explain the effect of surrounding air pressure on a sealed balloon.
The balloon will expand when the surrounding air is removed.
And also demonstrate that liquid boils at reduced temperature when the surrounding air pressure is reduced with instructions.
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Kidney Section, Nephrons , Blood Vessels And Renal Corpuscle
Description
Set of three models on one board. Kidney section, 3 times full size. Nephrons and blood vessels 120 times full size showing a section through renal cortex and medulla. Malpighian corpuscle of kidney,700 times enlarged showing an opened Malpighian corpuscle with glamerules and Bowman’s capsule. On base with key card.Laplace Law Apparatus
Moving Coil Multi Range Meter
Description
For DC & AC current and voltage. The operation of these meters depend on the reaction of the current circulating in the moving coil and a field of a fixed permanent magnet. Considering the operational nature and design of these instruments. the scale is linear. Since, the direction of the movement rotation depends on the direction of the current flow (polarity) in the circuit. The moving coil multirange meter can be used on direct current circuit and also alternating current with a suitable rectifier inserted in the circuit.| Accuracy | DC + F.S.D. & AC + 2.5 F.S.D. |
| Scale Length | 60 mm approx. with knife edge pointer and anti parallel mirror scale. |
| Dial Size | 80x80 mm, rectangular. |
| Moving Coil Multirange Voltmeter has following ranges | DC & AC 0-5 - 25 - 50 - 100 - 250 - 500V |
| Moving Coil Multirange Ammeter has following ranges | DC & AC 10 mA - 100mA - 500 mA - 1A - 2.5A - 5A |
Autoclave Vertical Sterilizer
Specifications
Made of stainless steel with the inner chamber of a thick pressure gauge. The outer surface has a mirror polish. The lid of this autoclave is thick along with a safety valve, pressure release valve, and drain valve. Spring loaded valve to adjust the pressure. Works on 220V AC. Radial or wing nut type door locking. Digital temperature indicator. Water level indicator.| Dimension | Power | Capacity | |
|---|---|---|---|
| 250x450mm | 2KW | 22litres | |
| 300x500mm | 3KW | 40litres | |
| 350x550mm | 4KW | 50litres | |
| 400x600mm | 5KW | 75litres | |
| 450x600mm | 5KW | 95litres | |
| 550x750mm | 6KW | 187litres |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Evolution
Separating Throttling Calorimeter
AIM
To find out dryness fraction of steam by combined separating and throttling calorimeter.
PRODUCT DETAILS
The steam passing out from separating calorimeter may still contain some water vapour , in it . in other words it may not be absolutely dry . again , in a throttling calorimeter steam after passing through the throttle valve must be superheated or at least dry saturated . this limits the extent of dryness fraction that can be reliably measured , depend up on the pressure of steam in the main steam pipe . if a sample of steam, which may be still wet after passing through the throttle valve i.e it will not be superheated . thus under this condition the throttling calorimeter fails to enable us in determining the value of dryness fraction of steam . to overcome this difficulties we make use of separating and throttling calorimeter . first the steam is passed through separating calorimeter where itlosses most of it’s moisture and becomes comparatively drier, it is than passed through the throttling calorimeter where super heating takes place with out changr of total heat . the temperature and pressure of steam after throttling are measured by using a thermometer and manometer respectively.DESCRIPTION
The set up consist of a separating and throttling calorimeter . a steam generator is provided at the base of the apparatus . a thermostat knob is provided at the front of apparatus to control the temperature inside the steam generator . steam from steam generator is passed from separating calorimeter where most of the water partical get separated from steam and then passed to throttling calorimeter where steam get superheated . after that superheated steam passed through heat exchanger to condense the steam.SAPARATING CALORIMETER
It consist of two concentric chamber , the inner chamber ,and the outer chamber . which communicates with each other through an opening at the top. As the steam discharge through the metal baskets ,which has a large number of holes , the water partical due to there heavier momentum get separated from the steam and collected in the chamber. The comparatively dry steam in the inner chamber moves up and than down aging through the annular space between the two chambers and enters the throttling calorimeter .THROTTLING CALORIMETER
It consist a narrow throat . pressure and temperature are measured by manometer and thermometer . the steam after throttling process passed through the heat exchanger and condensate is collected .UTILITIES REQURIED
1.WATER SUPPLY 3 lit/min (approx) 2.Drain 3.Electric supply : 1phase , 220 V A.C , 2Amp. 4.Steam table for calculation 5.Space required : 1.0 m X 1.0 mIce Melting Kit
Description
Demonstrates the difference in thermal conductivity of two different materials. The kit consists of two identical blocks, one made of aluminum and other made of plastic. When an ice cube is placed on aluminum it turns into water in seconds, while on plastic block it melts slowly. The aluminum block has a larger heat capacity and a higher thermal conductivity while the plastic block has lower values of both parameters. With instructions.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Balance Weights
Polished brass, supplied with wooden block, as illustrated.
• Capacity 500 gm. Comprising 1x200 gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5 gm, 2x2 gm, 1x1 gm
• Capacity 1000 gm. Comprising 1x500 gm, 1x200 gm, 2x100 gm, 1x50 gm, 1x20 gm, 2x10 gm, 1x5 gm, 2x2 gm, 1x1 gm.
• Capacity 2000 gm. Comprising 1x1000 gm, 1x500gm, 1x200gm, 2x100gm, 1x50gm, 1x20gm, 2x10gm, 1x5gm, 2x2gm, 2x2gm, 1x1gm.
Thin Cylinder Apparatus
A heavy bench top unit for studying the stress and strain in a thin walled cylinder under internal pressure. A thin walled cylinder is mounted between two support blocks. Internal pistons and seals create oil sealing. A handwheel at one end of the apparatus enables the cylinder end conditions to be adjusted to either open or closed. The internal pressure is adjusted by means of a hydraulic hand pump on the apparatus. An analogue pressure gauge displays the internal pressure whilst a pressure transducer gives feedback to the Data Acquisition Interface and Software supplied. Strain gauges are arranged on the external surface of the cylinder to measure the radial and circumferential surface strain. The strain gauges are at various angles.
XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT
















