XTEMOS ELEMENT
AJAX PRODUCTS TABS
Resistance Coils
Hydraulic Brake Actual Working Front Disc Rear
Epicyclic Gear Train Holding Torque Apparatus
It is a motorized unit consisting of SUN gear mounted on input shaft. Two plane gears mesh with the annular gear. These planet gears are mounted on a common arm to which output shaft is fitted. Loading arrangement is provided for loading the system and to measure Holding Torque.
Specifications:
1. External type Epicyclic Gear Train: a. Bearing blocks for input & output shafts. b. A gear train with Holding drum and handle. 2. Internal Type Epicyclic Gear Train: a. A compact Gear Train. b. Variable speed D.C. Motor c. Rope brake arrangement to measure output torque and holding torque. 3 Control Panel comprising of a. Digital Ammeter and Voltmeter. b. RPM Indicator. c. Speed Controller.Experimentation –
1. To measure epicyclical gear ratio between Input shaft and Output shaft. 2. To measure epicyclical gear ratio between Input shaft and holding drum. 3. To measure Input torque, Holding torque and Output torque.Service Required –
1. Floor Space – about 1.5m x 2m. 2. 230 V.AC stabilized power supply.Model of Female Breast
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Transformer Stand and Core
Description
Apparatus is designed primarily for demonstration of the basic principles of transformers. It consists of a laminated U-core with laminated I-core, both with 32 x 25 mm cross section to form a closed core of size 102 x 127 mm. Heavy aluminium alloy stand with removable clamping rods, 2 pole pieces, each 65 x 30 x 25 mm with one end cone shaped, to accept support rod and shading ring. Poles also have a hole drilled through lengthwise to take a light beam. 300 turns 600 turns 1200 turns 3600 turns 12000 turnsAir Conditioning Trainer General Cycle Type
The unit consists of ducting fitted with various air conditioning components. Airflow is generated by an axial flow fan and in the airflow, heaters, cooling coil and steam humidifier connection is provided. Cooling circuit consists of a hermetic compressor; air cooled condenser, thermostatic expansion valve and evaporator (i.e. cooling coil). Measurements of various parameters Torn cooling cycle and heating cycle are provided and students can easily visualize and understand the basic principles of air conditioning.
SPECIFICATIONS:
1.Cooling circuits – It consists of: a) Hermetic compressor, having the capacity of 2/3 ton of refrigeration (approx.) using R-22 refrigerant. b) Rotameter for liquid refrigerant flow measurement. c) Pressure gauges for high and low pressure. d) Prescott (i.e. high and low pressure cut-out). e) Thermometers for temperature measurement at various points In the cycle. f) Energymeter for compressor input measurement. g) Condensate measuring arrangement. 2.Heating Circuit – Air heaters with input control provided with energymeter for input measurement. Maximum heating capacity 1 Kw. 3.Steam generator and injector for humidification of air. All above components are connected to a duct of size 200mm. X 200mm. in which airflow is generated by axial flow fan. 4.Anemometer for measurement of air velocity, (range 0-15 m/sec. Following experiments can be conducted on the unit a) Cooling of atmospheric air. b) Heating of atmospheric air. c) Humidification of atmospheric air. d) Dehumidification and heating of atmospheric air. (Cooling coil acts as dehumidifier at reduced airflow.)SERVICES REQUIRED:
1.440 V, 15 A, 3 Phase supply with earthing connection. 2.Floor space area about 3 m. X 2 m.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
2 Stroke Petrol Engine Sectional Working Model
Venturimeter Orificemeter Calibration Set Up
DESCRIPTION:-
The apparatus consists of two pipelines emerging out from a common manifold. One pipeline contain a Venturimeter, second contains an Orifice. The pressure tapings from the Venturimeter and Orificemeter are taken to differential manometer to measure pressure difference. The Venturimeter and Orificemeter are connected in parallel and anyone of them can be put in operation by operating valves provided at the downstream. These valves can also regulate the flow. Present Set-up is self contained water re-circulating unit, provided with a sump tank and a centrifugal pump. Flow control valve and by-pass valve are fitted in water line to conduct the experiment on different floe rate. Flow rate of water is measured with the help of measured with the help of measuring tank and stop watch.EXPERIMENTS:-
Ø To determine the Co-efficient of discharged through Venturimeter and Orificemeter Ø To measure discharge through Venturimeter and Orificemeter as flow meters.UTILITIES: –
Ø Water Supply & Drain Ø Electricity Supply: Single Phase, 220 VAC, 0.5 kWTECHNICAL SPECIFICATIONS: –
Ø Venturimeter : Material Clear Acrylic, Compatible to 1” Dia pipe Ø Orificemeter : Material Clear Acrylic, Compatible to 1” Dia. Pipe Ø Water Circulation : FHP Pump, Crompton / Sharp make Ø Flow Measurement : Using Measuring Tank, Capacity 25 Ltrs. Ø Sump Tank : Capacity 50 Ltrs. Ø Stop Watch : Electronic Ø Control Panel : On / Off Switch, Mains Indicator etc. Ø Tanks will be made of Stainless Steel Ø The whole Set-up is well designed and arranged in a good quality painted StructurePulse Code Modulation/Demodulation
FEATURES:
• In-built sine wave generator • Test points to study different waveforms • In-built DC Power supplyTechnical Specifications:
• Sine wave Generator : Frequency : 1 KHz, Amplitude : 0 to 3Vpp • DC Voltage : -1.5 V to +1.5V • Clock Generator : Crystal based, 4.096MHz • Data rate : 64 kbps (for 8 KHz sampling rate)128kbps (for 16 KHz sampling rate) • ADC and DAC bits : 8 • Demodulator filter type : Butterworth low pass filter • Filter type : 6th • Filter cut-off frequency : 3.4 KHz • Mic Pre-amplifier : Transistor based • Compandingrange : -80dBm to +20dbm • Switched faults : 4 • Test points : 35 • Fuse : 30V, 100mV • DC Supply : ±5V, ±12V • System Bandwidth : 3.4 KHzResistance Substitution Board
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Parallelogram of Forces Apparatus
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Ray Box
Description
To provide a simple means of producing single or multiple rays of light for use in elementary optics. Made of die-cast alloy, the ray box has an open front and vertical internal grooves to accommodate a slit plate and a cylindrical lens. Supplied complete with a metal plate having single and triple slits, a 12 V 24 W SBC line filament lamp and a lamp holder.Power Steering Trainer System Actual Working
Power Steering Trainer System – Actual Working
The working of steering system is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of steering system are shown in actual working form. This model helps the student to understand the working of the steering system very easily. It is specially made dissectible for demonstration purposes.
Grease Spot Photometer
8085 Microprocessor LC LCD Trainer
Specification
• Intel 8085A CPU @ 6.144 MHz Clock speed. • RAM : 8KB expandable upto 32KB, Jumper selectable. • EPROM : 8KB expandable upto 32KB, Jumper selectable. • Lithium Battery Back up for RAM • PC Keyboard (104Keys) • 16x2 Alphanumeric Dot Matrix Liquid crystal display with back light • 3 Channel 16 Bit counter / timer terminated in a 10 pin connector using 8253 • 24/22 TTL I/O lines, terminated at 1 No of 26-Pin FRC connector by using 1 No of 8255/1No 8155 respectively • 8 Nos of Digital inputs terminated and given through on board 8 way Dip switch • 8 Nos of Digital outputs are terminated and displayed in the 8 Nos of SMD type LEDs • Digital I/O lines are terminated in 20-Pin connector • RS 232C compatible Serial port terminated in a 9-pin 'D' male connector • One VXT-Bus (50-Pin FRC Connector) for interfacing VBMB series of experiment boards for bus expansion. • Interrupts are terminated in a 5-Pin connector • Built in Line Assembler and Disassembler provided. • Software single stepping of user programs by instruction for software debugging.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT