XTEMOS ELEMENT
AJAX PRODUCTS TABS
Model of Compound Microscope (BI STU)
Human Skin
Ballistic Galvano Meters
Description
Used for measurement of small quantities of electrical charge. Levelling Screws for balancing the coil. Coil with mirror suspended between long suspension at the upper end and a spring at lower end. Clamping arrangement for transportation. Consistent sensitivity over a large period. Strip provided for making it a periodic. Res. in Ohm Crit. Damp. Res. in Ohms Sensitivity mm per m Coul. Sensitivity mm per m Amp. Time period in Seconds.100 | 300 | 1000 | 12 | 2000 |
500 | 600 | 1400 | 12 | 3500 |
Decade Inductance Box – 7 Dial
Description
Housed in a box with seven dials and fitted with 4 mm output plugs, the unit allows a range of inductances from 1ΩH to 10ΩH. 7 Decade Inductance Box (i) 1ΩH to 10ΩH in steps of 1ΩH (ii) 10ΩH to 100ΩH in steps of 10ΩH (iii) 100ΩH to 1mH in steps of 100ΩH (iv) 1mH to 10mH in steps of 1mH (v) 10mH to 100mH in steps of 10mH (vi) 100mH to 1mH in steps of 100mH (vii) 1mH to 10mH in steps of 1mHXTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE

Human Teeth With Tongue
Window Air Conditioning Actual Cut Section
This model will be made out of original parts. The model will be suitably sectioned to demonstrate the internal construction details showing the minute information, and working of the same, the model will be suitably painted and mounted on a metal or wooden base & supplied with key card & very interesting literature regarding working of the same.
Shell Tube Heat Exchanger Water To Water
Heat exchanger is the devices used to transfer the heat from one fluid to other. The shell and tube heat exchanger is two tube single pass heat exchanger. The hot fluid is hot water obtained from water heater. The coil fluid is cold water. The schematic flow arrangement is shown in figure. Hot water enters the lower side of end box, flows through the tubes in lower half of shell and comes to the other end of the shell. It reverses its direction, flows through tubes in upper half of the shell and leaves out. Cold water enters lower part of the shell passes over the tubes between the baffles and leaves out the shell through outlet at upper surface of shell.
SPECIFICATIONS:
1.Shell – 150NB, 750 m.m. long provided with end boxes. a.One end box with divider plate. b.25% cut baffles – 4 Nos. in the shell. 2.Tubes – 4.5mm I.D., 6.35mm O.D.,250 m.m. length copper tubes with triangular pitch. 3.Instantaneous water heater, 3 Kw capacity, to supply hot water. 4.Thermometer for measuring the water temperature. 5.Valves to control hot and cold water flow.SERVICES REQUIRED:
1.3 P H, AC supply 2.Floor space 1.5m. X 1m, 3.230V, 15A, AC supply with earthing connection. 4.Water supply at the rate of about 10 lit/min at constant heat.XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Forced Convection Apparatus
The unit consists of a circular pipe; loosing heat by forced convection to air, being forced through it. Constant heat flux is added to pipe by an electrical heater, provided with input control. The pipe surface temperature is measured at various points along length of pipe. Temperature of air at inlet and outlet of test section are measured. Thus the students can calculate local and overall heat transfer coefficients in forced convection, at various airflow rates and various heat flux values.
SPECIFICATIONS:
1.Test pipe – 32mm NB GI pipe, 500 mm. long, heated by band heater, outside. Centrifugal blower to force air through test pipe with How control valve. 2.Variac 2A, capacity to force air through test pipe with flow control valve. 3.An orifice meter with differential water manometer. 4.Voltmeter and Ammeter to measure heater input. 5.Multichannel digital temperature indicator to measures various temperatures. 6.A technical manual accompanies the unit.SERVICES REQUIRED:
1.Bench area of about 1m. x 0.75 m. at working height. 2.239v, 15A, AC, supply with earthing connection.Plain Laboratory Desiccator
We offer premium range of Plain Laboratory Desiccator which can be availed at market leading price range. Plain Desiccator have excellent quality and durability.
Grease should be applied on the flanges to make it air tight.
Material : Polypropylene/ Polycarbonate
Particulars | Pack (Pcs) | |
---|---|---|
Desiccator (Plain) PP/PC 150 mm | 1 | |
Desiccator (Plain) PP/PC 200 mm | 1 | |
Desiccator (Plain) PP/PC 250 mm | 1 | |
Desiccator (Plain) PP/PC 300 mm | 1 |
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION

Hydraulic Drum Brake Actual Working Four Drum
Suspension Bridge Apparatus
DESCRIPTION:
Cables are frequently used to support loads over large spans such as cable stayed for suspension bridges, cable car systems and stadium roof. They are used extensively for permanent guys on structures such as microwave towers and derricks. They are also used for temporary guys during erection. The only force in a cable is direct tension. They are too flexible to carry any moment. A cable is used to carry concentrated loads, uniformly distributed load along its length and uniformly distributed load along the horizontal span. It takes the shape of a polygon under concentrated loads, a catenary under uniform load along its length (such as its own weight), and a parabola under uniform load along the horizontal span.EXPERIMENT:
• Study the Extension of each spring Balance Left & Right Both. • Study of the effect of a point loadTECHNICAL SPECIFICATION:
• Apparatus Consists of two mild steel cables 0.5cm diameter in cross section and 150cm long, pinned to two supports 90cm apart situated symmetrically. • One of the ends can be converted to a roller by applying a known load at the end with the help of suspended pulley system. • Vertical loads can be applied at various points along the span of the beam. • A dial gauge with 25mm travel (with a magnetic base) is to be supplied with the apparatus complete with a supporting stand and a set of weights.XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Atomic Model Set
We present to you, Atomic Model Set.
The Atomic Model Set consists of moulded balls of different colors & sizes along with connectors of different sizes.
The sizes & shapes of the balls & connecting lugs have been designed in accordance with internationally acceptable standards.
Material : Polystyrene
Particulars | Pack (Pcs) | |
---|---|---|
Atomic Model Set - Senior Set | 1 | |
Atomic Model Set - Junior Set | 1 | |
Atomic Model Set (Euro Design) - Student Set | 1 | |
Atomic Model Set (Euro Design) - Teacher Set | 1 |
Magnifier, Reading Glass
Advanced Surgical Suture Arm
Description
Interchangeable arterial and venous inserts within the fore arm allow creation of arteriovenous (AV) fistulas and placement of AV grafts, while a simulated healed fistula insert provides a platform on which hemodialysis exercises can be performed. An additional multi-layer insert in the bicep area can be used for incision and suture training exercises.Advanced Arterial Patient Training Arm Features:
Subcutaneous injection sites on the volar forearm and lateral upper arm Intra Muscular injection site on the upper arm Arterial system including the radial and brachial arteries Suture and incision sites on both the upper arm and forearm Hem dialysis site on the forearm Arterial and Venous insert for IV and blood draw exercises, AV anastomosis, and placement of AV grafts. This multi-layer surgical insert includes the skin, subcutaneous tissue, muscle, radial artery, and radial vein AV fistula insert that simulates a healed fistula for hem dialysis exercises. Multi-layer bicep insert that includes the skin, subcutaneous tissue, and muscle and allows incision and suturing exercises Durable skin that can be pierced in excess of 200 times with a 20 or 22 gauge needle Realistic tactile feedback for both surgical and arterial & venous stick exercises Adjustable heart rate and pulse strength simulating a heart rate from 10 BPM to 150BPM Cephalic (antecubital), Basilic, Radial, and Ulnar veins as well as the radial and brachial arteries for infusion and blood draw. Rotating arm allowing dorsal and volar access along the length of the arm. Varying vessel palpability to simulate collapsed or bulging vessels and ease of assembly. Latex-Free New proprietary materials replicate of skin, subcutaneous, and muscle layers at all surgical sites. Upgraded inserts, skins, and vessels for improved tactile feedback Micro pump embedded within the shoulder generates variable heart rates and pulse strength. Easy to replace plug-and-play inserts to allow quick change-out between procedures. Latex-free vessels with improved access for hassle-free replacement.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent
XTEMOS ELEMENT