Micro Cover Glass
Made from clear optical glass, the cover glasses are uniform in size and free from scratches and striations. Packed in plastic box for easy handling.
Pack of 10 gms
Size
Square Size
18x18mm.
19x19mm.
22x22mm.
Rectangular Size
22x30mm.
22x40mm.
22x50mm.
22x60mm.
24x50mm.
24x60mm.
Circular Size
18mm.
19mm.
22mm.
24mm.
Pregnancy Pelvis With Baby
Dental Care Model(With Cheek), PVC
XTEMOS ELEMENT
AJAX PRODUCTS TABS SIMPLE
Autoclave, Radial Locking
Specification
Double wall chamber Autoclave. The inner chamber and outer wall made of stainless steel, ring made of stainless steel/ mild steel. The lid is made of stainless steel tightened by radial arms through a steering wheel made of chrome plated mild steel. The instrument is absolutely leak proof. Equipped with pressure gauze, safety valve, double safety valve, steam release valve, rubber gasket, inner container, S.S bucket and mild steel legs for Autoclave. The Autoclave can hold the in between 5psi to 20 psi. Autoclave, Vertical, Double Walled, Radial Locking.| Capacity (Lt.) | Size | |
|---|---|---|
| 23 litres | (10” x 18”) | |
| 40 litres | (12” x 22”) | |
| 52 litres | (14” x 22”) | |
| 60 litres | (14” x 25”) | |
| 75 litres | (16” x 24”) | |
| 95 litres | (18” x 24”) | |
| 180 litres | (22” x 30”) |
HVDC Transmission Line Simulator
The HVDC Transmission due to its advantages, like long distance transmission, interconnect different power systems (like 50Hz and 60Hz), more energy transmits than AC, less losses, make it essential for the students to study & understand the operation of HVDC. Vi Micro have introduced a trainer for this purpose “HVDC Transmission Line Simulator”
HVDC Transmission Line System consists of
• Generating Station Module • Rectifier Station Module (SCR or IGBT Based) • Simulated HVDC Transmission Line Module • Inverter Station Module • Loading ModuleGenerating Station Module
• It consists of a 3Φ, 415V Variable AC source, 1.5 KVA step up transformer, a Multifunction Meter (To measure various electrical parameters of • Generating side or sending end) & a Miniature Circuit Breaker. • Earth Fault Relay is provided for protection against Earth Fault. • The module is covered with metallic enclosure and sticker represents the prime operation of the module. Safety power plug-sockets are provided.Rectifier Station
• Two no’s of fully controlled SCR based bridge rectifiers provided to convert 3Φ AC to DC for HVDC transmission. • Two 6 Pulse SCR bridges connected in series • Can be configured as 12 Pulse Rectifier • A 3Φ, 1.5KVA transformer with (Y) primary and dual (Δ, Y) secondary are provided to reduce harmonics • The module is covered with metallic enclosure and sticker represents the prime operation of the module.Lens Holder Wooden
XTEMOS ELEMENT
AJAX PRODUCTS TABS ALTERNATIVE
Fashion
Level Control Measurement Module
This module consists of a process tank with a miniature pump, level sensor for 2 levels, a power supply, etc., To establish a ON/OFF control for the level of water. Circuitry is provided for stand alone operation or through a 8255 port of a Microprocessor kit.
Specification
• A transparent tank of height 150mm with adjustable electrodes to vary the high level and low level. • A pump with tank for water circulation • Water level can be monitored under software control/automatic mode • One power relay 230V/6Amp for pump ON/OFF control • Miniature connectors are provided to operate as stand alone controller or through software under a Microprocessor trainer. • Built in power supply.Bio-Agent Cage Acrylic
Wave Machine, Powell’s
XTEMOS ELEMENT
AJAX PRODUCTS TABS ARROWS PAGINATION
Stereo Microscope
Specifications
| Objective Lens | : | 1x & 2x. | |
| Eyepiece Lens | : | WF 10x/20mm (or 15x on request) (Paired) | |
| Magnification | : | 10x or 20x (15x or 30x with 15x eye piece) |
Episiotomy Training Simulator
Description
Suturing Simulators provide a realistic way for students to learn good surgical techniques. The simulators provide students with a variety of repair experiences without the constraint of time and concern for safety, which are factors with a live patient. The simulators can be used by the student in a learning lab with an instructor or by the student individually in the clinical setting just prior to a patient experience. They are also useful as homework teaching aids that can be signed out at night and returned the next day. In addition to being portable, the lifelike texture allows the learner to develop a “feel” for instrument handling, tension on suture, and the advantages of one method of tying knots over another.Includes one of each simulator:
Midline Suture Simulator Left Mediolateral Suture Simulator Right Mediolateral Suture Simulator Each simulator comes with an instruction booklet and is individually boxed.Human Heart ,4 parts
Matt White Screen
XTEMOS ELEMENT
AJAX PRODUCTS TABS WITH ICONS
Full Functional Elderly Nursing Manikin
Description
Designed according to the demand of the clinical principles and the guidelines of nursing training. This multifunctional simulator could simulate an actual circumstance for practice. Multiple functions, rural practice, easy assembly, well shaped appearance and correct anatomical landmarks provides a very good training for practice.Features:
Head Care Body care Patient moving Different lying pose Bilateral and Unilateral oxygen inhalation Atomization inhalation therapy Nasal Feeding Gastric lavage training Intravenous Injection Intramuscular Injection Hypodermic Injection Various fistula orifice washing practice Female Catheterization Female Bladder Washing Enema Treatment Simulator AssemblyWorm Sector Type Steering System
Worm & Sector Type Steering System – Actual Working
The working of steering system is shown with the help of actual parts assembled on square iron pipe frame. All the necessary parts of steering system are shown in actual working form. This model helps the student to understand the working of the steering system very easily. It is specially made dissectible for demonstration purposes.
Female Catheterization Training Simulator
Description
With the female catheterization trainer, female bladder catheterization procedures can be realistically demonstrated, practiced and assessed. The genital inserts are placed into the anatomically correct lower abdominal model and held in place with magnets.The material is soft and flexible:
the foreskin is movable and the penis can be stretched. The material gives a realistic feeling when inserting and removing the catheter into the bladder with realistic resistance and insertion depths.Direct learning:
When the catheter has been correctly inserted, fluid runs out, just like with a real patient. The catheter can also be checked through the transparent bladder. The abdominal wall can be removed so that the process can be viewed better.Includes suprapubic catheter:
If it is no longer possible to carry out catheterization through the urethra, a suprapubic catheter can be inserted. On the PRO version, a suprapubic catheter has already been put in place, and the student can practice cleaning it and taking care of it with the trainer.All the benefits of the female catheterization simulator at a glance:
Female catheterization with realistic resistance Soft and movable labia (for practicing disinfection, for example) Anatomically realistic pelvic structure Liquid outflow if catheterization is successfully carried out The transparent bladder can be checked and the abdominal wall can be removed. Includes suprapubic catheter for practicing, cleaning and caring for it. Stands securely on the table thanks to the non-slip feet Magnetic connectors for quick set-up and dismantling Easy to clean and maintain and can be completely taken apart A sponge on the inside prevents a build-up of moistureDemonstration Gear Model System
Description
A series of models to demonstrate different gearing systems. With transparent slideplates, the gears may easily be seen and where necessary there is an index on the primary and secondary shafts to show the change in the direction of rotation and the relative speed of rotation. A simple three-speed and reverse-gear system using spur gears. Reverse gear is obtained by interposing a small lay-shaft mounted pinion between the two main shafts. Gear selection is by means of a short ball-ended lever.XTEMOS ELEMENT
AJAX PRODUCTS TABS LOAD MORE PAGINATION
SILICA CRUCIBLE WITHOUT LID
PRODUCT DESCRIPTION
- Crucible is glazed inside and outside.
- Highly resistant to alkalis and hot temperatures
- 50ml capacity
- Outside diameter 55mm, 42mm height
- No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML
SILICA CRUCIBLE TALL FORM Without Lid, Translucent