XTEMOS ELEMENT

AJAX PRODUCTS TABS

Featured
  • Featured
  • Accessories
  • Furniture

Slip Creep Measurement Apparatus

The apparatus consists of a variable speed D.C. Motor, Driving pulley and Driven pulley of equal diameter. The pulleys are mounted on input shaft (Motor shaft) and output shaft. The driven pulley can slide on the base with bearing block to change initial tension in belt. Brake drum is mounted on output shaft helps to measure power output. The motor speed is varied by dimmerstat. A two channel RPM Indicator is provided to measure speeds of driven and driving pullies respectively.

Specifications:

1.D.C. Motor – 1 HP, 1500 RPM, variable speed. 2.Driving & Driven puilies of equal diameters. 3.Brake drum along with spring balance. 4.Fiat Belt of fixed length of following materials – (i)Fabric Belt (ii)Canvas Belt. (iii)Rubber Belt. 5.Belt tightening arrangement. 6.Speed Controller unit. 7.Two Channel digital RPM Indicator. 8.Stroboscope.

Experimentation –

1. To measure co-efficient of friction between pulley material and different belt materials. 2. To measure power transmitted with varied belt tensions and plotting graph of (T1 – T2).Tension Characteristics. 3. To measure percentage slip at fixed belt tension by varying load on brake drum and plot graph of (T1-T2) Vs.percentage slip.i.e. Slip Characteristics. Finding a creep zone from graph. 4. To measure belt slip speed and observe the limiting value float at constant speed when the slip just starts.

Service Required:

1.230 V.A.C. stabilized power supply 2.Space -. 1.5m x 1.5 m.

Blood Collection Vials (VACUTAINER) Plain/EDTA

Blood collection and storage is done is special tubes which allow the preservation of the blood sample over long periods. These tubes can be made of glass or plastic and the caps of these vials are coloured to indicate the additives in them. Some of the additives are anticoagulants such as EDTA, sodium citrate or heparin. Other substances include preservatives. The containers containing coagulants are capped with gold, red or orange caps. The ones containing anti-coagulants are green, which contain heparin, purple or lavender indicates ones which contain EDTA, grey capped tubes contain sodium fluoride or oxalate. Blood collection tubes (also called as vacutainers) are extensively used in hospitals, medical centres and diagnostic centres. In biological labs, it is used in experiments like haemolysis etc. Non Vacuum Vials (Pk of 100) Vacuum Vials (Pk of 100)

Charle’s Law Kit

Description

A glass U-tube of 10 mm diameter the shorter limb of which has a stopcock near top and the longer limb can take a plastic tube. A scale is provided and can be attached to the shorter limb With red indicator oil but without 2000 ml tall form beaker which acts as a reservoir.
XTEMOS ELEMENT

AJAX PRODUCTS TABS SIMPLE

shirt-tab
Fashion
Featured
  • Featured
  • Man
  • Woman

Burettes with Rota Flow Stopcock (BG)

Capacity ml
25
50
100
10 ml with Cup Top (Micro Burette)
5 ml with Cup Top (Micro Burette)
1 ml or 2 ml (Any One) with Cup Top (Micro Burette)

Hydraulic Bench Apparatus

OBJECTIVE:

To conduct the experiment of hydraulic bench, with separate experiential set ups i.e. Hydrostatic Pressure, Flow over Weirs, Bernoulli’s Theorem, Flow meter Demonstration, Impact of jet and Orifice Discharge etc. which are accessories of the Hydraulic Bench.

DESCRIPTION OF APPARATUS:

The set up is a self-contained, water recirculation unit provided with a top tray, sump tank and a measuring tank. Drain valve and over-flow are provided on the sump tank. A centrifugal pump is fitted for water circulation. Flow control valve and bypass valve is fitted in water line to conduct the experiment at different flow rates. Flow rate of water is measured with the help of measuring tank and stop watch. Measuring tank is provided to measure the discharge. Drain valve is provided in the measuring tank to empty water in sump tank after measuring discharge. Separate level indicator and scale is provided to read the level of water in the measuring tank.

UTILITIES REQUIRED:

1.Water Supply (Fill approx 250 Ltrs Initially). 2.Drain Required. 3.220 V AC, 50 Hz, single phase electric supply source. 4.Floor area 1.75 m x 1.50 m.

SPECFICATION:

1. Top Tray : 1060 mm x 650 mm. 2.Pump : 1 HP 3.Flow Measurement : Using measuring Tank (Material SS) 4.Tank : Capacity 40 Ltr. 5.Sump Tank : Capacity 120 Ltr. Material SS. The whole set-up is well designed and arranged in a good quality powder coating painted structure.

Bar & Gauge

Description

To illustrate expansion of metal on heating and contraction on cooling, with steel bar of length 100 x 10 mm and plated brass gauge with a cutout to just accommodate the bar and two holes through which the bar passes when cold.

Volcanic System

Description

Shows different parameters how volcanoes take place & the hanging feature thereafter.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ALTERNATIVE

Fashion
Featured
  • Featured
  • Man
  • Woman

Dead Weight Pressure Gauge Tester

DESCRIPTION:-

Dead weight Pressure Gauge Tester is manufactured to measure the Pressure gauge up to the capacity of 25kg/cm2.The system is nickled chrome to protect from rust. The weights are Zink Iron for long term use.

EXPERIMENTS:-

• Study of the hydrostatic force on a plane surface under different submerged conditions

FEATURES:-

• Superb Painted structure • Simple to operate & maintain

UTILITIES REQUIRED:-

• Machine Oil.

SPECIFICATION:-

• Bourdon tube pressure gauge as manometer • Manometer with transparent scale • Manufactured from corrosion resistant materials • Components arranged on base plate. • Set of weights • Medium for transmitting pressure: hydraulic

Concentric Tube Heat Exchanger

(A)Plain Tube ( Water To Water ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. While the outer tube consists of GI pipe through which cold water flows. The arrangement enables the parallel and counter flow of the cold water. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D, 12.7mm. and outer G. I. Pipe I. D. 15mm. approx. and 1.5m. length. 2.Thermometers – 4 nos. 3.Measuring flask – 1 Lit. capacity. 4.Geyser-3 kW. Single phase.

Services required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x I m x 1 m height. (B) Finned Tube ( Water To Air ): The apparatus consists of two concentric tubes. Inner tube consists of copper tube through which hot water flows. It is finned at its outer diameter to increase the heat transfer surface. While the outer tube consists of GI pipe through which cold air flows. The arrangement enables the parallel and counter flow of the air. The inlet and outlet temperatures and the flow measurement enable to find out the heat exchanged LMTD, and effectiveness of the equipment.

Specifications:

1.Inner copper tube I.D. 12.7mm. and outer G. I. Pipe I. D. 25mm. approx. and 1m. length. 2.Thermometers – 4 nos. 3.Orifice meter along with manometer. 4.Measuring flask – 1 Lit. Capacity. 5.Geyser-3 kW. Single phase.

Services Required

1.220v, 15A, stabilized single-phase AC supply. 2.Floor area – 3m x 1m x 1m height.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ARROWS PAGINATION

shirt-tab
Electronics
Featured
  • Featured
  • Mobile
  • Smartwatches

Kidney With Bladder

Description

Natural size kidney, ureters, adrenal glands and bladder with prostate as well as the large abdominal right kidney sectioned to show all anatomical details. mounted on base.

Dean & Stark Apparatus with Stopcock

For Estimation of Moisture in lubricating oils with one 10ml receiver flask & 1Ltr. R.B Flask

Moving Coil Multi Range Meter

Description

For DC & AC current and voltage. The operation of these meters depend on the reaction of the current circulating in the moving coil and a field of a fixed permanent magnet. Considering the operational nature and design of these instruments. the scale is linear. Since, the direction of the movement rotation depends on the direction of the current flow (polarity) in the circuit. The moving coil multirange meter can be used on direct current circuit and also alternating current with a suitable rectifier inserted in the circuit.
AccuracyDC + F.S.D. & AC + 2.5 F.S.D.
Scale Length60 mm approx. with knife edge pointer and anti parallel mirror scale.
Dial Size80x80 mm, rectangular.
Moving Coil Multirange Voltmeter has following rangesDC & AC 0-5 - 25 - 50 - 100 - 250 - 500V
Moving Coil Multirange Ammeter has following rangesDC & AC 10 mA - 100mA - 500 mA - 1A - 2.5A - 5A
XTEMOS ELEMENT

AJAX PRODUCTS TABS WITH ICONS

Furniture
  • Furniture
  • Lighting
  • Accessories
  • Clocks
  • Cooking

Typical Flower L.S.

Description

A model showing the L.S. of a flower, mounted on board with key card.

Leaf Area Meter

Description

Leaf Area Meter We have been affianced in offering an exclusive collection of Leaf Area Meter which is used to obtain measurements of leaf area without detaching the leaf from the plant. The offered meter is manufactured with the use of high grade components and latest tools in order to meet the set industry standards. These are extensively used for conducting various tests and studies on the leaves of a tree.

CRUCIBLE TONG (STAINLESS STEEL)

DESCRIPTION
  • Bow pattern

    • Jaws have serrated edges
    • Available in a range of sizes
 
  • Available size:
  • 6”
  • 8”
  • 10”
  • 12”
  • 18”
  • 24”
   

Ticker Tape Timer 12V

Ticker Tape Timer 12V These devices use an electromagnet which activates a striker, producing dots via a carbon disk on the ticker tape. With 4mm terminal sockets. The dots are produced at a rate of 50 - 60Hz depending on the mains frequency. There are 6V and 12v units available. The Ticker Tape Timers are used in the measurement of velocity, acceleration and general timing.
XTEMOS ELEMENT

AJAX PRODUCTS TABS LOAD MORE PAGINATION

Featured
  • Featured
  • Lighting
  • Accessories

SILICA CRUCIBLE WITHOUT LID

PRODUCT DESCRIPTION
  • Crucible is glazed inside and outside.
  • Highly resistant to alkalis and hot temperatures
  • 50ml capacity
  • Outside diameter 55mm, 42mm height
  • No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML

SILICA CRUCIBLE TALL FORM Without Lid, Translucent

PRODUCT DESCRIPTION -Without lid, translucent, glazed - Ordinary type lids to be purchased separately Size/ dimension:
  • 20ml,  Dia. 35mm x Ht. 38mm
  • 30ml, Dia. 43mm x Ht. 38mm
  • 50ml, Dia. 51mm x Ht. 51mm

SILICA MUFFLE TRAYS (For VM Crucible)

PRODUCT DESCRIPTION:   Available in 2types:  Two Hole, 39mm Length Four Hole, 76mm Length
XTEMOS ELEMENT

AJAX PRODUCTS TABS CAROUSEL

Featured
  • Featured
  • Cooking
  • Furniture