XTEMOS ELEMENT

AJAX PRODUCTS TABS

Featured
  • Featured
  • Accessories
  • Furniture

Monocot Stem Anatomy T.S &L.S

Description

This model exhibits the various tissues and the scattered, closed and collateral vascular bundles in transverse and longitudinal sections in maize. The large pitted vessels, spiral and annular vessels show the cell wall thickenings in L.S. Useful model for teaching anatomy of monocot stem. Mounted on base with keycard.

Suspension Bridge Apparatus

DESCRIPTION:

Cables are frequently used to support loads over large spans such as cable stayed for suspension bridges, cable car systems and stadium roof. They are used extensively for permanent guys on structures such as microwave towers and derricks. They are also used for temporary guys during erection. The only force in a cable is direct tension. They are too flexible to carry any moment. A cable is used to carry concentrated loads, uniformly distributed load along its length and uniformly distributed load along the horizontal span. It takes the shape of a polygon under concentrated loads, a catenary under uniform load along its length (such as its own weight), and a parabola under uniform load along the horizontal span.

EXPERIMENT:

• Study the Extension of each spring Balance Left & Right Both. • Study of the effect of a point load

TECHNICAL SPECIFICATION:

• Apparatus Consists of two mild steel cables 0.5cm diameter in cross section and 150cm long, pinned to two supports 90cm apart situated symmetrically. • One of the ends can be converted to a roller by applying a known load at the end with the help of suspended pulley system. • Vertical loads can be applied at various points along the span of the beam. • A dial gauge with 25mm travel (with a magnetic base) is to be supplied with the apparatus complete with a supporting stand and a set of weights.

Sieve Shaker (Gyratory Motion)

Ensuring durability during performance, this machine is made of mild steel and cast iron and comes with one Lid and a Pan. This unit is used with up to 7 sieves of 150mm or 200mm (8 Inch) sieves and up to 6 sieves of 300 mm (12 Inch). Heavy duty motor (1/4 HP) ensures the whole performance through a reduction gear immersed in oil. Along with featuring gyratory motion, this units also performs upward and downward movement ensuring that each "square cm" of the sieve is fully utilized. This Gyratory Sieve Machine also supplied with a pair of rods and a holder which ensures tight grip of sieve set from the top.
Product:Gyratory Sieve Shaker 
Capacity:7 sieves of 150mm, 6 sieves of 300mm 
Design:Table Top 
Construction: Cast Iron, Painted Mild steel 
Motor: ¼ HP 
Timer: 0 - 60 Minutes 
Timer Type: Digital / Analog 
Power Supply: 220 Volts 

Lichens

Lichen Thallus VS Lichen Apothecium VS
XTEMOS ELEMENT

AJAX PRODUCTS TABS SIMPLE

shirt-tab
Fashion
Featured
  • Featured
  • Man
  • Woman

Permeability Cup

(S.S 304) 120mm Dia. Permeability cups for determining the water-vapor transmission of paints, varnishes, coatings, coating systems and related products. The Permeability cup consists of a cup, seal ring and cover ring. The seal ring is designed to prevent turning when closing the cover. The Permeability cup is suitable for testing both self-supporting coating and non-self-supporting coatings. Water-vapor transmission is of interest for high humidity conditions. The wet cup method is thus the reference method for determining water-vapor transmission, if agreed up on otherwise, other procedures or conditions the dry cup method may be used.

Dip Needle

Description

Revolving in pivots, with a graduated quadrant, rotatable on a base marked every 45°.

Ripple Tank

Description :- Transparent acrylic plastic ripple tank, supported in a sturdy plastic frame which has recesses to hold four legs with leveling feet. The tank edges are shaped to minimize undesired reflections. Tank has a drain hole closed by a rubber stopper. With two light alloy uprights to carry a horizontal rippler support rod which is adjustable for height. The ripple assembly, elastically suspended from the support rod, consists of a 4 – 6 V DC motor mounted on a wooden beam. The motor has an eccentric weight which causes the beam to oscillate. Two point sources are provided by two plastic spheres, each mounted on a right angle rod. A metal rod is fixed centrally into a socket in one short side of the frame to afford support to the illuminant. Overall size of the tank 580 x 500 x 80 mm, window area 370 x 280 mm, height of tank above bench level (with legs attached) approx. 375 mm. Complete with following accessories :- 1. Two straight obstacles of aluminium alloy length 130 mm. 2. One straight obstacle length 40 mm. 3. One curved reflector radius 200 mm. 4. One trapezoidal plastic plate for refraction. 5. One wood hand wave roller. 6. One water dropper. 7. One pkt. rubber bands. 8. One foam plastic sponge. 9.One illuminant with a 12 V, 24 W lamp mounted in a lamp house and provided with a long supporting rod.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ALTERNATIVE

Fashion
Featured
  • Featured
  • Man
  • Woman

Razor Steel

The Razor is made of surgical quality steel with 75mm cutting edge.

Genetics

Description

All Charts are made on PVC rexine, hand drawn, waterproof, in fast multi colors with a black background. Each chart is provided with rollers to hang on wall, Size 75×100 cm. Monohybrid Crossing complete dominance Monohybrid Crossing incomplete dominance Dihybrid Crossing Monohybrid Crossing Mendelian explanation of Cross between tall & dwarf races in Garden Pea Sex linked inheritance Drosophila Mendelian Heridity of Blue & Adulsian fowls Mendelian Explanation of the breeding behaviour of Red & White flowering in 4 o’clock

Action of Cams

Description

For the construction of a unit to demonstrate cam action and the effect of different cam profiles cut from card.

Two Input or Gate

To study the OR digital logic gate and verification of the truth table.
XTEMOS ELEMENT

AJAX PRODUCTS TABS ARROWS PAGINATION

shirt-tab
Electronics
Featured
  • Featured
  • Mobile
  • Smartwatches

Low Voltage Coils, For Demountable Transformer

Description

Each wound on a rectangular insulated bobbin, connections by 4 mm sockets spaced at 19 mm

Interference Undercutting

The board shows the demonstration of this phenomenon of Interference and Undercutting. When we rotate the teeth in anticlockwise direction, as the teeth is undercut is gives us a smooth working. When we give a rotation in clockwise direction, we can observe that the rack tip will be resisted by the tooth flank thus giving interference.

Histology Set III

Set of 25 slides consisting of
AppendixCardiac Stomach
CerebellumCiliated epithelium
Cuboidal EpitheliumDeveloping tooth
Fundic StomachJoint articulation
Mammary glandMedulla gland
Medulla oblongataOsteogenesis
PlacentaPlyoric stomach
Recto anal junctionRed bone marrow
Salivary glandSpleen
Stratified squamous epitheliumThymus gland
TongueTransitional epithelium
VaginaWhite fibrous tendon
Yellow elastic ligament 
XTEMOS ELEMENT

AJAX PRODUCTS TABS WITH ICONS

Furniture
  • Furniture
  • Lighting
  • Accessories
  • Clocks
  • Cooking

Cytology Mitotic Cell Division

Educational Equipments Manufacturer, Exporters & Suppliers - School Educational Equipments Manufacturers & Exporters of Educational Equipments for Lab. Science Lab Products, Teaching Aids, Classroom Instruments, Educational Laboratory Interphase Stage Prophase Stage Metaphase Stage Anaphase Stage Anaphase Stage Telophase Stage Set of 5 Slides, as above

Band Brake Working Model

Consists of a brake drum mounted on a shaft, free to rotate in bearings. A flexible band is wrapped partly around the drum. Brake force can be applied with the help of Lever. Complete on iron base.

Plate Type Heat Exchanger Apparatus

The unit consists of a plate type heat exchanger, in which cold fluid is cold water and hot fluid is hot water, which is obtained from geyser. The inlet and outer connections of the fluids are positioned so as to make the exchanger counter flow type. Hot and cold fluids pass between alternate plates various measurements provided enables the students to determine heat transfer rate, LMTD, heat transfer coefficients and effectiveness of the heat exchanger.

SPECIFICATIONS:

1.Heat Exchanger- S.S. Plate heat exchanger wiles nos. of 200 X 400mm. 2.Geyser to obtain hot water – 3 KW capacity. 3.Calibrated water flow measuring vessel 4.Thermometers to measure inlet and outlet temperatures of fluid. 5.Flow controls valves. A technical manual accompanies the unit.

OPTIONAL ACCESSORIES:

Rotameters to measure water flow rates instead of measuring vessel. Multi channel digital temperature Indicator to measure the temperatures instead of thermometers.

SERVICES REQUIRED:

1.Floor space 1.5m. X 1m, 2.230V, 15A, AC supply with earthing connection, 3.Water supply at the rate of about 10 lit/min at constant heat.
XTEMOS ELEMENT

AJAX PRODUCTS TABS LOAD MORE PAGINATION

Featured
  • Featured
  • Lighting
  • Accessories

SILICA CRUCIBLE WITHOUT LID

PRODUCT DESCRIPTION
  • Crucible is glazed inside and outside.
  • Highly resistant to alkalis and hot temperatures
  • 50ml capacity
  • Outside diameter 55mm, 42mm height
  • No lid includedSilica crucible is glazed inside and outside. Highly resistant to alkalis and hot temperature SIZES ARE: 15ML 25ML 50ML 80ML 100ML 150ML

SILICA CRUCIBLE TALL FORM Without Lid, Translucent

PRODUCT DESCRIPTION -Without lid, translucent, glazed - Ordinary type lids to be purchased separately Size/ dimension:
  • 20ml,  Dia. 35mm x Ht. 38mm
  • 30ml, Dia. 43mm x Ht. 38mm
  • 50ml, Dia. 51mm x Ht. 51mm

SILICA MUFFLE TRAYS (For VM Crucible)

PRODUCT DESCRIPTION:   Available in 2types:  Two Hole, 39mm Length Four Hole, 76mm Length
XTEMOS ELEMENT

AJAX PRODUCTS TABS CAROUSEL

Featured
  • Featured
  • Cooking
  • Furniture